Maddalena Coccagna

Dr. Maddalena Coccagna

University of Ferrara (Italy), Department of Architecture
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 February 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Elisabetta CaselliElisabetta Caselli
Elisabetta Caselli
MDMaria D'Accolti
Maria D'Accolti
AVAlberta Vandini
Alberta Vandini
LLLuca Lanzoni
Luca Lanzoni
MCMaria Teresa Camerada
Maria Teresa Camerada
SMSante Mazzacane
Sante Mazzacane
Contamination of hospital surfaces by clinically-relevant pathogens represents a major concern in healthcare facilities, due to its impact on transmission of healthcare-associated infections (HAIs) and to the growing drug resistance of HAI-associated pathogens. Routinely used chemical disinfectants show limitations in controlling pathogen contamination, due to their inefficacy in preventing recontamination and selection of resistant strains. Recently we observed that an innovative approach, based on a cleanser added with spores of non-pathogenic probiotic Bacilli, was effective in stably counteracting the growth of several pathogens contaminating hospital surfaces. Here, we wanted to study the impact of the Bacillus-based cleanser on the drug-resistance features of the healthcare pathogens population. In parallel, the ability of cleanser-derived Bacilli to infect hospitalized patients was also investigated. Collected data showed that Bacilli spores can germinate on dry inanimate surfaces, generating the bacterial vegetative forms which counteract the growth of pathogens and effectively substitute for them on treated surfaces. Strikingly, this procedure did not select resistant species, but conversely induced an evident decrease of antibiotic resistance genes in the contaminating microbial population. Also importantly, all the six HAI-positive patients hosted in the treated areas resulted negative for probiotic Bacilli, thus adding evidences to their safety-to-use. These results indicate that this probiotic-based procedure is active not only in controlling surface microbial contamination but also in lowering drug-resistant species, suggesting that it may have relevant clinical and therapeutical implications for the management of HAIs.

12 July 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Elisabetta CaselliElisabetta Caselli
Elisabetta Caselli
SBSilvio Brusaferro
Silvio Brusaferro
MCMaddalena Coccagna
Maddalena Coccagna
LALuca Arnoldo
Luca Arnoldo
FBFilippo Berloco
Filippo Berloco
FGfor the SAN-ICA Study Group
for the SAN-ICA Study Group
Healthcare Associated Infections (HAI) are a global concern, further threatened by the increasing drug resistance of HAI-associated pathogens. On the other hand, persistent contamination of hospital surfaces contributes to HAI transmission, and it is not efficiently controlled by conventional cleaning, which does not prevent recontamination, has a high environmental impact and can favour selection of drug-resistant microbial strains. In the search for effective approaches, an eco-sustainable probiotic-based cleaning system (Probiotic Cleaning Hygiene System, PCHS) was recently shown to stably abate surface pathogens, without selecting antibiotic-resistant species. The aim of this study was to determine whether PCHS application could impact on HAI incidence. A multicentre, pre-post interventional study was performed for 18 months in the Internal Medicine wards of six Italian public hospitals (January 1st 2016—June 30th 2017). The intervention consisted of the substitution of conventional sanitation with PCHS, maintaining unaltered any other procedure influencing HAI control. HAI incidence in the pre and post-intervention period was the main outcome measure. Surface bioburden was also analyzed in parallel. Globally, 11,842 patients and 24,875 environmental samples were surveyed. PCHS was associated with a significant decrease of HAI cumulative incidence from a global 4.8% (284 patients with HAI over 5,930 total patients) to 2.3% (128 patients with HAI over 5,531 total patients) (OR = 0.44, CI 95% 0.35–0.54) (P<0.0001). Concurrently, PCHS was associated with a stable decrease of surface pathogens, compared to conventional sanitation (mean decrease 83%, range 70–96.3%), accompanied by a concurrent up to 2 Log drop of surface microbiota drug-resistance genes (P<0.0001; Pc = 0.008). Our study provides findings which support the impact of a sanitation procedure on HAI incidence, showing that the use of a probiotic-based environmental intervention can be associated with a significant decrease of the risk to contract a HAI during hospitalization. Once confirmed in larger experiences and other target populations, this eco-sustainable approach might be considered as a part of infection control and prevention (IPC) strategies. Trial registration—ISRCTN International Clinical Trials Registry, ISRCTN58986947.

5 December 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Elisabetta CaselliElisabetta Caselli
Elisabetta Caselli
SPSimonetta Pancaldi
Simonetta Pancaldi
Costanza BaldisserottoCostanza Baldisserotto
Costanza Baldisserotto
FPFerruccio Carlo Petrucci
Ferruccio Carlo Petrucci
AIAnna Impallaria
Anna Impallaria
SMSante Mazzacane
Sante Mazzacane
It is important to characterize the microorganisms involved in biodeterioration processes to understand their effects on cultural assets and to define an efficient strategy for protecting artworks, monuments, and buildings from microbiological recolonization. In this study, we analyzed the microbial communities dwelling on the verso (front) and recto (back) sides of a 17th century easel painting attributed to Carlo Bononi, an Italian artist of the first Baroque period. Cultivable bacteria and fungi colonizing the painting were isolated and identified in order to characterize the microbial community possibly involved in deteriorating the pictorial layer of the painting. The isolated bacterial strains belonged to the Staphylococcus and Bacillus genera. Furthermore, culture-dependent techniques and SEM/EDS analyses revealed the presence of filamentous fungi of the genera Aspergillus, Penicillium, Cladosporium, and Alternaria. The chemical compositions of pigments were consistent with typical 17th century paintings, and some of the identified pigments, namely red lac and red and yellow earths, could be exploited as nutrient sources by painting-associated microorganisms. The study also evaluated, in vitro, the potential decontaminating activity of a biocompound, containing spores of Bacillus subtilis, Bacillus pumilus, and Bacillus megaterium. The results indicated the ability of this biocompound to counteract the growth of contaminating microorganisms that are potentially dangerous to the painting, suggesting the potential use of these microorganisms to prevent biodeterioration of artworks.

1 August 2018 in Energy Procedia
Verified
Journal Article
Open access
SCSilvia Cesari
Silvia Cesari
PVPaolo Valdiserri
Paolo Valdiserri
MCMaddalena Coccagna
Maddalena Coccagna
SMSante Mazzacane
Sante Mazzacane

24 April 2020 in Energies
Verified
Journal Article
Open access
PDF file
SCSilvia Cesari
Silvia Cesari
Paolo ValdiserriPaolo Valdiserri
Paolo Valdiserri
MCMaddalena Coccagna
Maddalena Coccagna
SMSANTE MAZZACANE
SANTE MAZZACANE
If not properly designed, the adoption of large windows can sometimes have a negative impact on building energy demand. For this reason, aggravated by the outdated building envelope of the healthcare building stock, large fenestration systems are usually avoided in hospitals, especially in old structures. However, with appropriate glazing specifications, the adoption of wider openings can result into significant energy savings, lower costs and strong positive effects on patients and staff well-being. The present study investigates how different window sizes and types of glazing affect heating, cooling and lighting energy demand in a hospital patient room. The objective is to evaluate the energy savings that may be obtained when installing larger windows and to identify the glazing properties allowing one to reach the maximum energy reductions. Simulations were carried out using nine diverse glazing systems, already available on the market, and their energy performance was evaluated in relation to two different window areas: a common size opening, characterized by a 25% Window-to-Wall Ratio (WWR), and a floor to ceiling window, with 77% WWR. The analysis was conducted taking into consideration four different orientations in four Italian cities, supposing two artificial lighting control strategies. The results highlighted how the adoption of wider windows with appropriate glazings and a daylight-linked dimming lighting control strategy may lower the primary energy demand up to 17%.

11 March 2025 in Buildings
Verified
Journal Article
Open access
PDF file
VBVincenzo Ballerini
Vincenzo Ballerini
MCMaddalena Coccagna
Maddalena Coccagna
MBMatteo Bisi
Matteo Bisi
AVAntonella Volta
Antonella Volta
LDLorenzo Droghetti
Lorenzo Droghetti
SMSANTE MAZZACANE
SANTE MAZZACANE
Indoor air quality (IAQ) plays a vital role in supporting both the physical and mental well-being of individuals in enclosed spaces, and the role of mechanical ventilation systems has gained increasing attention due to building design’s focus on energy efficiency and thus airtight constructions. This study investigated the pre–post effects of installing a heat recovery mechanical ventilation system (MVHR) on indoor air quality in a high school classroom in Ferrara, Italy. The analysis focused on experimental measurements of temperature (T), relative humidity (RH), and carbon dioxide (CO2) both inside and outside the same classroom, which had constant occupancy (17 students) for an entire school year, allowing a comparison between natural and mechanical ventilation. With a comprehensive approach, particulate matter (PM2.5), volatile organic compounds (VOCs), and radon levels (Rn) were monitored as well, after the installation of the MVHR. By comparing natural and mechanical ventilation, the study highlights the strengths and limitations of the ventilation system implemented, together with an evaluation of the system’s energy consumption, including a 2 kW post-heating battery. In terms of results, the MVHR demonstrated clear benefits in managing CO2 levels and improving sensory, olfactory, and psychophysical well-being, as well as the attention levels of students. In detail, under natural ventilation, peak concentrations exceeded 4500 ppm, while mechanical ventilation kept them below 1500 ppm. The average CO2 concentration during occupancy dropped from 2500 ppm to around 1000 ppm, achieving a 62% reduction. However, beneficial effects were not observed for other parameters, such as PM2.5, VOCs, or radon. The latter displayed annual average values around 21 Bq/m3 and peaks reaching 56 Bq/m3.