Paolo Valdiserri

Prof. Dr. Paolo Valdiserri

Department of Industrial Engineering, Alma Mater Studiorum Università di Bologna, Bologna, Emilia-Romagna, Italy
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2025 in Energy and Buildings
Verified
Journal Article
Open access
HNHamed Namdar
Hamed Namdar
ESEugenia Rossi di Schio
Eugenia Rossi di Schio
GSGiovanni Semprini
Giovanni Semprini
Paolo ValdiserriPaolo Valdiserri
Paolo Valdiserri

29 August 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Eugenia Rossi di SchioEugenia Rossi di Schio
Eugenia Rossi di Schio
VBVincenzo Ballerini
Vincenzo Ballerini
Matteo DongelliniMatteo Dongellini
Matteo Dongellini
Paolo ValdiserriPaolo Valdiserri
Paolo Valdiserri
In this paper, dynamic simulations of the seasonal coefficient of performance (SCOP) of Air-Source Heat Pumps will be presented by considering three different heat pump systems coupled with the same building located in three different Italian municipalities: S. Benedetto del Tronto (42°58′ North, 13°53′ East), Milan (45°28′ North, 9°10′ East), and Livigno (46°28′ North, 10°8′ East). Dynamic simulations were conducted by employing the software package TRNSYS and by considering real weather data (i.e., outdoor air temperature and humidity as well as solar radiation) referring to the three abovementioned cities for a period of 8 years (2013–2020) and collected from on-site weather stations. Attention has been paid to the modeling of the heat pump defrost cycles in order to evaluate their influence on the unit’s seasonal performance. Results show that, when referring to different years, the thermal energy demand displays huge variations (in some cases it can even double its value), while the effective SCOP is characterized by scarce variability. Sensible variations in SCOP values are achieved for Livigno.

24 April 2020 in Energies
Verified
Journal Article
Open access
PDF file
SCSilvia Cesari
Silvia Cesari
Paolo ValdiserriPaolo Valdiserri
Paolo Valdiserri
MCMaddalena Coccagna
Maddalena Coccagna
SMSANTE MAZZACANE
SANTE MAZZACANE
If not properly designed, the adoption of large windows can sometimes have a negative impact on building energy demand. For this reason, aggravated by the outdated building envelope of the healthcare building stock, large fenestration systems are usually avoided in hospitals, especially in old structures. However, with appropriate glazing specifications, the adoption of wider openings can result into significant energy savings, lower costs and strong positive effects on patients and staff well-being. The present study investigates how different window sizes and types of glazing affect heating, cooling and lighting energy demand in a hospital patient room. The objective is to evaluate the energy savings that may be obtained when installing larger windows and to identify the glazing properties allowing one to reach the maximum energy reductions. Simulations were carried out using nine diverse glazing systems, already available on the market, and their energy performance was evaluated in relation to two different window areas: a common size opening, characterized by a 25% Window-to-Wall Ratio (WWR), and a floor to ceiling window, with 77% WWR. The analysis was conducted taking into consideration four different orientations in four Italian cities, supposing two artificial lighting control strategies. The results highlighted how the adoption of wider windows with appropriate glazings and a daylight-linked dimming lighting control strategy may lower the primary energy demand up to 17%.


8 August 2018 in Energies
Verified
Journal Article
Open access
PDF file
Cesare BiserniCesare Biserni
Cesare Biserni
Paolo ValdiserriPaolo Valdiserri
Paolo Valdiserri
Dario D'OrazioDario D'Orazio
Dario D'Orazio
Massimo GaraiMassimo Garai
Massimo Garai
Promotion of retrofit actions on existing buildings is a goal in Italy, since most of them were built before the 80′s when little attention was paid to energy saving. This paper presents an integrated passive design approach to reduce the heating demand and limit the costs of a representative existing residential complex located in Bologna, in the northern part of Italy. To this purpose, we explored different scenarios upon actions taken on the building structure: (1) High efficiency windows; (2) additional insulation on the external walls; or (3) the simultaneous application of high efficiency windows and improved thermal envelope, on both external walls and roofing. The numerical optimization has been performed dynamically using TRNSYS simulation tool, to evaluate energy consumptions in different structural conditions. Then, the developed model has been calibrated by the real consumption data deduced from energy bills (years 2009–2015). Finally, the energy results obtained in the above mentioned different scenarios have been evaluated under an economic assessment of cost investment: It has been highlighted that the payback time (PBT) results to be strongly influenced by the national policies of fiscal incentives. According to the present model, the most profitable condition is obtained when additional insulation on the external walls is applied: The total amount of energy saving resulted to be equal to 930.4 MWh, with an optimal PBT of roughly six years, when tax refund was contemplated.

17 June 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Matteo DongelliniMatteo Dongellini
Matteo Dongellini
CNChristian Natale
Christian Natale
Claudia NaldiClaudia Naldi
Claudia Naldi
Eugenia Rossi di SchioEugenia Rossi di Schio
Eugenia Rossi di Schio
Paolo ValdiserriPaolo Valdiserri
Paolo Valdiserri
Gian Luca MoriniGian Luca Morini
Gian Luca Morini
The European Parliament has imposed to reduce by 2030 whole HFC emissions by at least two-thirds with respect to 2014 levels. With the aim of contributing to determine the energy and environmental advantages of refrigerants alternative to R-410A, this paper reports the results of a numerical study focused on an HVAC system coupled to a residential building and based on a reversible electric heat pump. In particular, two heat pump typologies are considered: an air-source and a ground-source heat pump, both operating with the two refrigerants R-410A and R-454B. The environmental performance of the studied system is assessed by means of the TEWI (total equivalent warming impact) index. The adoption of R-454B involves a slight decrease (2–3%) in the overall annual energy performance of the system with respect to the use of R-410A. On the other hand, the working fluid R-454B guarantees a marked decrease in the TEWI indicator. Indeed, considering the current Italian emission factor of electricity taken from the grid, the total emissions over the entire heat pump operating life drop by about 25% and can decrease by up to 89% in perspective, following the current reduction trend of the emission factor.