Agnieszka Włodyka-Bergier

Dr. Agnieszka Włodyka-Bergier

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2021 in Environmental and Experimental Botany
Verified
Journal Article
Closed access
ATAriel E. Turcios
Ariel E. Turcios
RTRosa Maria Miglio Toledo
Rosa Maria Miglio Toledo
RVRosemary Vela
Rosemary Vela
GSGiovanna Sánchez
Giovanna Sánchez
TBTomasz Bergier
Tomasz Bergier
Jutta PapenbrockJutta Papenbrock
Jutta Papenbrock

1 February 2017 in Desalination and Water Treatment
Verified
Journal Article
Open access
Mariola RajcaMariola Rajca
Mariola Rajca
AWAgnieszka Włodyka-Bergier
Agnieszka Włodyka-Bergier
Michał BodzekMichał Bodzek
Michał Bodzek
TBTomasz Bergier
Tomasz Bergier

14 February 2014 in Desalination and Water Treatment
Verified
Journal Article
Open access
AWAgnieszka Włodyka-Bergier
Agnieszka Włodyka-Bergier
TBTomasz Bergier
Tomasz Bergier
MKMałgorzata Kot
Małgorzata Kot
The goal of this paper is to analyze the Krakow water distribution systems regarding the occurrence of volatile halogenated water disinfection by-products from the group of trihalomethanes (trichloromethane, bromodichloromethane, dibromochloromethane, and tribromomethane), haloacetonitriles (bromochloroacetonitrile, dibromoacetonitrile, dichloroacetonitrile, and trichloroacetonitrile), haloketones (1,1-dichloro-2-propanone and 1,1,1-trichloro-2-propanone), chloropicrin (trichloronitromethane), and chloral hydrate. The research was conducted since February 2011 to March 2012; water samples were taken from the ends of the pipe system and analyzed. Two water distribution systems were selected for the research: the first one supplied with water from the water treatment plant (WTP) Raba, and second one—from WTP Bielany. These systems differ in water quality, applied water treatment processes, and the size of the water distribution system, however, in both plants chlorination is applied for the disinfection process. Each month, five samples were taken from the distribution system of WTP Bielany, and six samples from WTP Raba for research. During the entire research period, totally, 154 samples were taken (84 from WTP Raba distribution system and 70 from WTP Bielany one), in which 12 by-products were analyzed. The results of this analysis were used to assess the occurrence of volatile water disinfection by-products in the considered water distribution systems.

16 January 2025 in Sustainability
Verified
Journal Article
Open access
PDF file
AWAgnieszka Włodyka-Bergier
Agnieszka Włodyka-Bergier
TBTomasz Bergier
Tomasz Bergier
ESEmilia Stańkowska
Emilia Stańkowska
To achieve sustainable swimming pool water management, it is necessary to minimize the consumption of energy, water, and chemical agents to maintain the appropriate water quality. Some of the pollutants are introduced by swimmers and can be relatively easily removed if swimmers take a shower before entering a pool. Thus, this research questions how much of an impact this simple act could have on the water quality and generally on sustainable water management in swimming pools. To address this question, experiments were conducted at the AGH Swimming Pool in Kraków, in a real facility—a hot tub—with the participation of volunteers who took a shower in Variant 1 and did not in Variant 2. The assessment was made on the basis of selected microbiological and physicochemical parameters of swimming pool water, including disinfection by-products. The research results proved that taking a shower can significantly reduce the load of pollutants users introduce into swimming pool water and can contribute to more efficient and ecological treatment of swimming pool water and minimize the negative impact on the health of swimming pool users (microbiological contaminants and precursors of harmful chlorination by-products).

16 August 2021 in Energies
Verified
Journal Article
Open access
PDF file
AWAgnieszka Włodyka-Bergier
Agnieszka Włodyka-Bergier
TBTomasz Bergier
Tomasz Bergier
UV lamps are being increasingly used in the treatment of swimming pool water, mainly due to their abilities to disinfect and effectively remove chloramines (combined chlorine). However, the application of UV lamps in a closed loop system, such as that in which swimming pool water is treated, creates conditions under which chlorinated water is then also irradiated with UV. Thus, the advanced oxidation process occurs, which affects the transformation of organic matter and its increased reactivity, and hence the higher usage of chlorine disinfectant. In addition, UV lamps require electrical power and the periodic replacement of filaments. In order to assess whether the application of a low-pressure UV lamp is justified, water quality tests and an analysis of the operating costs (including the energy consumption) of the water treatment system were carried out for two operation variants—those of the low-pressure UV lamp being turned on and off. The experiments were carried out on the real object of the AGH University of Science and Technology sports swimming pool for one year. The consumption of electricity and water treatment reagents was also measured. The following values of the selected parameters of the swimming pool water quality were observed (for without and with UV lamp, respectively): 0.68 and 0.52 mg/L combined chlorine; 3.12 and 3.02 mg/L dissolved organic carbon; 15.70 and 15.26 µg/L trihalomethanes; 7 and 6 cfu/mL mesophilic bacteria; and 6 and 20 cfu/mL psychrophilic bacteria. Generally, the statistically important differences in water quality parameters were not observed, thus the application of the low-pressure UV lamp in the swimming pool water treatment technology did not bring the expected improvement in water quality. However, the higher consumption of electric energy (by 29%) and chlorine disinfectant (by 15%), and the need to periodically replace the lamp filaments significantly increased the operating costs of the water treatment system (by 21%) and its ecological impact, thus this technology cannot be considered as profitable or ecological.

1 January 2016 in Desalination and Water Treatment
Verified
Journal Article
Open access
AWAgnieszka Włodyka-Bergier
Agnieszka Włodyka-Bergier
TBTomasz Bergier
Tomasz Bergier
The article presents the results of experiments on the potential of model solutions of urea, creatinine, glycine, histidine, and arginine to form several organic chlorination by-products. These precursors are the main organic-nitrogen compounds, whose sources in swimming pool water are sweat and urine of bathers. In the article, the formation potential of the following by-products has been presented and discussed: trichloromethane; monochloroacetic acid; dichloroacetic acid; trichloroacetic acid; trichloroacetonitrile; dichloroacetonitrile; 1,1-dichloropropanone; 1,1,1-trichloropropanone; chloral hydrate; and chloropicrin. The test on by-products formation potential was applied to conduct the experiments, and 24-h incubation time was applied for the swimming pool water samples, disinfected in three variants of treatment: (1) chlorination alone; (2) chlorination and Ultraviolet (UV) irradiation (cumulative dose 23.5 kJ/m2); and (3) chlorination and UV irradiation (cumulative dose 47 kJ/m2). The low-pressure UV lamp by Heraeus was used to irradiate the samples. The results of experiments have been discussed and analyzed to study the influence of UV radiation on the reactivity of individual model precursors and their potential to form halogenated organic chlorination by-products.