To achieve sustainable swimming pool water management, it is necessary to minimize the consumption of energy, water, and chemical agents to maintain the appropriate water quality. Some of the pollutants are introduced by swimmers and can be relatively easily removed if swimmers take a shower before entering a pool. Thus, this research questions how much of an impact this simple act could have on the water quality and generally on sustainable water management in swimming pools. To address this question, experiments were conducted at the AGH Swimming Pool in Kraków, in a real facility—a hot tub—with the participation of volunteers who took a shower in Variant 1 and did not in Variant 2. The assessment was made on the basis of selected microbiological and physicochemical parameters of swimming pool water, including disinfection by-products. The research results proved that taking a shower can significantly reduce the load of pollutants users introduce into swimming pool water and can contribute to more efficient and ecological treatment of swimming pool water and minimize the negative impact on the health of swimming pool users (microbiological contaminants and precursors of harmful chlorination by-products).
UV lamps are being increasingly used in the treatment of swimming pool water, mainly due to their abilities to disinfect and effectively remove chloramines (combined chlorine). However, the application of UV lamps in a closed loop system, such as that in which swimming pool water is treated, creates conditions under which chlorinated water is then also irradiated with UV. Thus, the advanced oxidation process occurs, which affects the transformation of organic matter and its increased reactivity, and hence the higher usage of chlorine disinfectant. In addition, UV lamps require electrical power and the periodic replacement of filaments. In order to assess whether the application of a low-pressure UV lamp is justified, water quality tests and an analysis of the operating costs (including the energy consumption) of the water treatment system were carried out for two operation variants—those of the low-pressure UV lamp being turned on and off. The experiments were carried out on the real object of the AGH University of Science and Technology sports swimming pool for one year. The consumption of electricity and water treatment reagents was also measured. The following values of the selected parameters of the swimming pool water quality were observed (for without and with UV lamp, respectively): 0.68 and 0.52 mg/L combined chlorine; 3.12 and 3.02 mg/L dissolved organic carbon; 15.70 and 15.26 µg/L trihalomethanes; 7 and 6 cfu/mL mesophilic bacteria; and 6 and 20 cfu/mL psychrophilic bacteria. Generally, the statistically important differences in water quality parameters were not observed, thus the application of the low-pressure UV lamp in the swimming pool water treatment technology did not bring the expected improvement in water quality. However, the higher consumption of electric energy (by 29%) and chlorine disinfectant (by 15%), and the need to periodically replace the lamp filaments significantly increased the operating costs of the water treatment system (by 21%) and its ecological impact, thus this technology cannot be considered as profitable or ecological.
This article presents the results of experiments on the effect of chlorine dioxide, applied as an additional oxidant, on swimming pool water quality. Three doses of chlorine dioxide were applied: 22, 44 and 66 mg/m3. At each research stage, prior to the actual experiment, in which the oxidant was dosed, the background was tested, i.e., water samples were taken from a conventional treatment system (without chlorine dioxide). The experiments showed that chlorine dioxide effectively removes organic compounds and their chlorine derivatives. For the highest dose of ClO2, CODMn decreased by almost 88% and chloroform concentration by 75%. Chlorine dioxide also effectively supports water disinfection. At the highest dose, the number of mesophilic bacteria decreased by 60% and the number of psychrophiles by 94%. However, after the dosing of this oxidant had been discontinued, a deterioration of the microbiological water quality and the secondary growth of microorganisms were observed. Chlorine dioxide also caused an increase in conductivity and the concentration of inorganic compounds (nitrates, total chlorates and chlorites). The effect of this agent on the combined chlorine concentration was not observed. The reported experiments have shown that this measure is not unequivocally beneficial in terms of improving swimming pool water quality.
1 January 2016 in Desalination and Water Treatment
Dynamic development of road infrastructure and a significant increase in the number of cars are important challenges making it necessary to rationally treat and manage stormwater polluted with oil derivatives. Ecological engineering can be a source of valuable solutions in this domain, which are in agreement with sustainability principles, friendly to environment and hydrological cycle, convenient and attractive to the users. The article presents the results of research on using constructed wetlands to remove oil derivatives, which have been conducted with the semi-technical scale experimental installation planted with Phragmites australis, treating stormwater from a car service station in Sosnowiec. The results and discussion focus on the concentration of individual aliphatic hydrocarbons, their sum, as well as the efficiency of their removal by the studied installation. Some additional parameters of analysed wastewater such as temperature, suspended solids, pH, conductivity and air temperature have been also presented and discussed. The condition of the reed population has been also evaluated and discussed. The concentration of total aliphatic hydrocarbons (C7–C40) in raw wastewater was on average 2,311.67 μg/L (121.08–17,664.02 μg/L) and much lower in treated wastewater −261.81 μg/L (77.09–532.56 μg/L). All measured hydrocarbons concentrations in wastewater flowing out of the experimental installation were much lower than the standard value, defined by Polish law for wastewater released to the environment or to the sewage system. Some relatively high values of the aliphatic hydrocarbons removal rate were also observed (averagely 67% for C7–C40 and 64% for C7–C30). The analysis of research results in relation to individual aliphatic hydrocarbons showed that most efficiently removed ones were hydrocarbon C20–C33 (on average around 80%), C34–C40 and C12–C19 with slightly lower efficiency (60–70%), and least efficiently—lightest hydrocarbons C7–C11. Common reed P. australis confirmed its high applicability in constructed wetlands which treat stormwater polluted with oil derivatives. Generally, the experiments confirm high potential of constructed wetlands to remove oil derivatives from wastewater.
1 December 2018 in Desalination and Water Treatment