Yongtao Lu

Prof. Yongtao Lu

Department of Engineering Mechanics, Dalian University of Technology, Dalian, China
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Yongtao LuYongtao Lu
Yongtao Lu
LCLiangliang Cheng
Liangliang Cheng
ZYZhuoyue Yang
Zhuoyue Yang
JLJunyan Li
Junyan Li
HZHanxing Zhu
Hanxing Zhu
Bone scaffolds are widely used as one of the main bone substitute materials. However, many bone scaffold microstructure topologies exist and it is still unclear which topology to use when designing scaffold for a specific application. The aim of the present study was to reveal the mechanism of the microstructure-driven performance of bone scaffold and thus to provide guideline on scaffold design. Finite element (FE) models of five TPMS (Diamond, Gyroid, Schwarz P, Fischer-Koch S and F-RD) and three traditional (Cube, FD-Cube and Octa) scaffolds were generated. The effective compressive and shear moduli of scaffolds were calculated from the mechanical analysis using the FE unit cell models with the periodic boundary condition. The scaffold permeability was calculated from the computational fluid dynamics (CFD) analysis using the 4×4×4 FE models. It is revealed that the surface-to-volume ratio of the Fischer-Koch S-based scaffold is the highest among the scaffolds investigated. The mechanical analysis revealed that the bending deformation dominated structures (e.g., the Diamond, the Gyroid, the Schwarz P) have higher effective shear moduli. The stretching deformation dominated structures (e.g., the Schwarz P, the Cube) have higher effective compressive moduli. For all the scaffolds, when the same amount of change in scaffold porosity is made, the corresponding change in the scaffold relative shear modulus is larger than that in the relative compressive modulus. The CFD analysis revealed that the structures with the simple and straight pores (e.g., Cube) have higher permeability than the structures with the complex pores (e.g., Fischer-Koch S). The main contribution of the present study is that the relationship between scaffold properties and the underlying microstructure is systematically investigated and thus some guidelines on the design of bone scaffolds are provided, for example, in the scenario where a high surface-to-volume ratio is required, it is suggested to use the Fischer-Koch S based scaffold.

23 May 2022 in Polymers
Verified
Journal Article
Open access
PDF file
YWYanli Wu
Yanli Wu
Yongtao LuYongtao Lu
Yongtao Lu
MZMing Zhao
Ming Zhao
SBSergei Bosiakov
Sergei Bosiakov
LLLei Li
Lei Li
With the ability to fabricate complex structures while meeting individual needs, additive manufacturing (AM) offers unprecedented opportunities for bone tissue engineering in the biomedical field. However, traditional metal implants have many adverse effects due to their poor integration with host tissues, and therefore new material implants with porous structures are gradually being developed that are suitable for clinical medical applications. From the perspectives of additive manufacturing technology and materials, this article discusses a suitable manufacturing process for ideal materials for biological bone tissue engineering. It begins with a review of the methods and applicable materials in existing additive manufacturing technologies and their applications in biomedicine, introducing the advantages and disadvantages of various AM technologies. The properties of materials including metals and polymers, commonly used AM technologies, recent developments, and their applications in bone tissue engineering are discussed in detail and summarized. In addition, the main challenges for different metallic and polymer materials, such as biodegradability, anisotropy, growth factors to promote the osteogenic capacity, and enhancement of mechanical properties are also introduced. Finally, the development prospects for AM technologies and biomaterials in bone tissue engineering are considered.

1 September 2019 in Journal of Biomechanics
Verified
Journal Article
Closed access
JLJunyan Li
Junyan Li
Yongtao LuYongtao Lu
Yongtao Lu
SMStuart C. Miller
Stuart C. Miller
ZJZhongmin Jin
Zhongmin Jin
XHXijin Hua
Xijin Hua

6 August 2024 in Frontiers in Materials
Verified
Journal Article
Open access
PDF file
VSVolha Siniauskaya
Volha Siniauskaya
HWHao Wang
Hao Wang
JJJian Jiang
Jian Jiang
YCYuhang Chen
Yuhang Chen
MZMichael Zhuravkov
Michael Zhuravkov
Yongtao LuYongtao Lu
Yongtao Lu
Metamaterials are artificially created materials or structures with properties not found in nature. They encompass electromagnetic, acoustic, and mechanical metamaterials, which are particularly significant in applied engineering. Mechanical metamaterials exhibit unique mechanical properties such as vanishing shear modulus, negative Poisson’s ratio, negative compressibility, etc. This paper reviews the most commonly used mechanical metamaterials and discusses their applications in the field of applied engineering, specifically in vibration isolation, energy absorption, and vibration reduction. The prospects for future developments in this field are also presented.

1 December 2020 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
Yongtao LuYongtao Lu
Yongtao Lu
ZCZhentao Cui
Zhentao Cui
LCLiangliang Cheng
Liangliang Cheng
JLJian Li
Jian Li
ZYZhuoyue Yang
Zhuoyue Yang
CWChengwei Wu
Chengwei Wu

1 August 2015 in Journal of Bone and Mineral Research
Verified
Journal Article
Open access
PDF file
GMGhislain Maquer
Ghislain Maquer
Yongtao LuYongtao Lu
Yongtao Lu
Enrico Dall'AraEnrico Dall'Ara
Enrico Dall'Ara
YCYan Chevalier
Yan Chevalier
MKMatthias Krause
Matthias Krause
PZPhilippe K Zysset
Philippe K Zysset
Trabecular bone score (TBS) rests on the textural analysis of dual-energy X-ray absorptiometry (DXA) to reflect the decay in trabecular structure characterizing osteoporosis. Yet, its discriminative power in fracture studies remains incomprehensible because prior biomechanical tests found no correlation with vertebral strength. To verify this result possibly owing to an unrealistic setup and to cover a wide range of loading scenarios, the data from three previous biomechanical studies using different experimental settings were used. They involved the compressive failure of 62 human lumbar vertebrae loaded 1) via intervertebral discs to mimic the in vivo situation (“full vertebra”); 2) via the classical endplate embedding (“vertebral body”); or 3) via a ball joint to induce anterior wedge failure (“vertebral section”). High-resolution peripheral quantitative computed tomography (HR-pQCT) scans acquired from prior testing were used to simulate anterior-posterior DXA from which areal bone mineral density (aBMD) and the initial slope of the variogram (ISV), the early definition of TBS, were evaluated. Finally, the relation of aBMD and ISV with failure load (Fexp) and apparent failure stress (σexp) was assessed, and their relative contribution to a multilinear model was quantified via ANOVA. We found that, unlike aBMD, ISV did not significantly correlate with Fexp and σexp, except for the “vertebral body” case (r2 = 0.396, p = 0.028). Aside from the “vertebra section” setup where it explained only 6.4% of σexp (p = 0.037), it brought no significant improvement to aBMD. These results indicate that ISV, a replica of TBS, is a poor surrogate for vertebral strength no matter the testing setup, which supports the prior observations and raises a fortiori the question of the deterministic factors underlying the statistical relationship between TBS and vertebral fracture risk. © 2015 American Society for Bone and Mineral Research.