Liangliang Cheng

Dr. Liangliang Cheng

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Yongtao LuYongtao Lu
Yongtao Lu
LCLiangliang Cheng
Liangliang Cheng
ZYZhuoyue Yang
Zhuoyue Yang
JLJunyan Li
Junyan Li
HZHanxing Zhu
Hanxing Zhu
Bone scaffolds are widely used as one of the main bone substitute materials. However, many bone scaffold microstructure topologies exist and it is still unclear which topology to use when designing scaffold for a specific application. The aim of the present study was to reveal the mechanism of the microstructure-driven performance of bone scaffold and thus to provide guideline on scaffold design. Finite element (FE) models of five TPMS (Diamond, Gyroid, Schwarz P, Fischer-Koch S and F-RD) and three traditional (Cube, FD-Cube and Octa) scaffolds were generated. The effective compressive and shear moduli of scaffolds were calculated from the mechanical analysis using the FE unit cell models with the periodic boundary condition. The scaffold permeability was calculated from the computational fluid dynamics (CFD) analysis using the 4×4×4 FE models. It is revealed that the surface-to-volume ratio of the Fischer-Koch S-based scaffold is the highest among the scaffolds investigated. The mechanical analysis revealed that the bending deformation dominated structures (e.g., the Diamond, the Gyroid, the Schwarz P) have higher effective shear moduli. The stretching deformation dominated structures (e.g., the Schwarz P, the Cube) have higher effective compressive moduli. For all the scaffolds, when the same amount of change in scaffold porosity is made, the corresponding change in the scaffold relative shear modulus is larger than that in the relative compressive modulus. The CFD analysis revealed that the structures with the simple and straight pores (e.g., Cube) have higher permeability than the structures with the complex pores (e.g., Fischer-Koch S). The main contribution of the present study is that the relationship between scaffold properties and the underlying microstructure is systematically investigated and thus some guidelines on the design of bone scaffolds are provided, for example, in the scenario where a high surface-to-volume ratio is required, it is suggested to use the Fischer-Koch S based scaffold.

14 October 2021 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
YHYi Huo
Yi Huo
YLYongtao Lu
Yongtao Lu
LMLingfei Meng
Lingfei Meng
JWJiongyi Wu
Jiongyi Wu
TGTingxiang Gong
Tingxiang Gong
LCLiangliang Cheng
Liangliang Cheng
In recent years, bone tissue engineering has emerged as a promising solution for large bone defects. Additionally, the emergence and development of the smart metamaterial, the advanced optimization algorithm, the advanced manufacturing technique, etc. have largely changed the way how the bone scaffold is designed, manufactured and assessed. Therefore, the aim of the present study was to give an up-to-date review on the design, manufacturing and assessment of the bone scaffold for large bone defects. The following parts are thoroughly reviewed: 1) the design of the microstructure of the bone scaffold, 2) the application of the metamaterial in the design of bone scaffold, 3) the optimization of the microstructure of the bone scaffold, 4) the advanced manufacturing of the bone scaffold, 5) the techniques for assessing the performance of bone scaffolds.

1 December 2020 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
Yongtao LuYongtao Lu
Yongtao Lu
ZCZhentao Cui
Zhentao Cui
LCLiangliang Cheng
Liangliang Cheng
JLJian Li
Jian Li
ZYZhuoyue Yang
Zhuoyue Yang
CWChengwei Wu
Chengwei Wu

20 January 2023 in Materials
Verified
Journal Article
Open access
PDF file
JWJiongyi Wu
Jiongyi Wu
YZYouwei Zhang
Youwei Zhang
Yongtao LuYongtao Lu
Yongtao Lu
LCLiangliang Cheng
Liangliang Cheng
As the application of bone scaffolds becomes more and more widespread, the requirements for the high performance of bone scaffolds are also increasing. The stiffness and porosity of porous structures can be adjusted as needed, making them good candidates for repairing damaged bone tissues. However, the development of porous bone structures is limited by traditional manufacturing methods. Today, the development of additive manufacturing technology has made it very convenient to manufacture bionic porous bone structures as needed. In the present paper, the current state-of-the-art optimization techniques for designing the scaffolds and the settings of different optimization methods are introduced. Additionally, various design methods for bone scaffolds are reviewed. Furthermore, the challenges in designing high performance bone scaffolds and the future developments of bone scaffolds are also presented.

15 September 2023 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
YLYuchen Liu
Yuchen Liu
FWFuyang Wang
Fuyang Wang
JYJiawei Ying
Jiawei Ying
MXMinghao Xu
Minghao Xu
YWYuan Wei
Yuan Wei
LCLiangliang Cheng
Liangliang Cheng
Objective: This study aimed to evaluate the biomechanical effectiveness of 3D-printed integrated acetabular prosthesis (IAP) and modular acetabular prosthesis (MAP) in reconstructing the acetabulum for patients with Crowe III developmental dysplasia of the hip (DDH). The results of this study can provide a theoretical foundation for the treatment of Crowe III DDH in total hip arthroplasty (THA).Methods: Finite element (FE) analysis models were created to reconstruct Crowe III DDH acetabular defects using IAP and MAP. The contact stress and relative micromotion between the acetabular prosthesis and the host bone were analyzed by gradually loading in three increments (210 N, 2100 N, and 4200 N). In addition, five patients with Crowe III DDH who underwent IAP acetabular reconstruction were observed.Results: At the same load, the peak values of IAP contact stress and relative micromotion were lower than those of MAP acetabular reconstruction. Under jogging load, the MAP metal augment’s peak stress exceeded porous tantalum yield strength, and the risk of prosthesis fracture was higher. The peak stress in the bone interface in contact with the MAP during walking and jogging was higher than that in the cancellous bone, while that of IAP was higher than that of the cancellous bone only under jogging load, so the risk of MAP cancellous bone failure was greater. Under jogging load, the relative micromotion of the MAP reconstruction acetabular implant was 45.2 μm, which was not conducive to bone growth, while under three different loads, the relative micromotion of the IAP acetabular implant was 1.5–11.2 μm, all <40 μm, which was beneficial to bone growth. Five patients with IAP acetabular reconstruction were followed up for 11.8 ± 3.4 months, and the Harris score of the last follow-up was 85.4 ± 5.5. The imaging results showed good stability of all prostheses with no adverse conditions observed.Conclusion: Compared with acetabular reconstruction with MAP, IAP has a lower risk of loosening and fracture, as well as a better long-term stability. The application of IAP is an ideal acetabular reconstruction method for Crowe III DDH.

3 March 2023 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
FWFuyang Wang
Fuyang Wang
YLYuchen Liu
Yuchen Liu
YHYi Huo
Yi Huo
ZWZiming Wang
Ziming Wang
JZJinge Zhang
Jinge Zhang
DZDeWei Zhao
DeWei Zhao
Objective: To select the most appropriate internal fixation method based on the Pauwels angle, in order to provide a new concept for clinical accurate treatment of femoral neck fractures (FNFs).Methods: FNFs models of Pauwels 30°; 40°; 50°; 60° were created respectively. For Pauwels ≤ 50°, 1, 2 and 3 Cannulated Compression Screws (CCS) and Porous Tantalum Screws (PTS) were used to fix the fracture for the models. For Pauwels 60°, 3CCS and Medial Buttress Plate (MBP) combined with 1, 2 and 3CCS were used to fix the fracture. Based on the results of the finite element (FE) analysis, the biomechanical properties of each model were compared by analyzing and evaluating the following four parameters: maximal stress of the bone (MBS), maximal stress of the implants (MIS), maximal displacement of bone (MBD), interfragmentary motion (IFM).Results: At Pauwels 30°, the larger parameters were found in 1CCS, which was 94.8 MPa (MBS), 307.7 MPa (MIS), 0.86 mm (MBD) and 0.36 mm (IFM). In 2CCS group, the parameters were 86.1 MPa (MBS), 254.4 MPa (MIS), 0.73 mm (MBD) and 0.27 mm (IFM), which were similar to those of PTS. At Pauwels 40°; 50°, with the increase of the number of used CCS, accordingly, the parameters decreased. Particularly, the MIS (Pauwels 50°) of 1CCS was 1,195.3 MPa, but the other were less than the yield range of the materials. At Pauwels 60°, the MBS of 3CCS group was 128.6 Mpa, which had the risk of failure. In 2CCS + MBP group, the parameters were 124.2 MPa (MBS), 602.5 MPa (MIS), 0.75 mm (MBD) and 0.48 mm (IFM), The model stability was significantly enhanced after adding MBP.Conclusion: Pauwels type Ⅰ (<30°) fractures can reduce the number of CCS, and PTS is an appropriate alternative treatment. For Pauwels type Ⅱ fractures (30°∼50°), the 3CCS fixation method is still recommended. For Pauwels type Ⅲ fractures (>50°), it is recommended to add MBP to the medial femoral neck and combine with 2CCS to establish a satisfactory fracture healing environment.