Zhanpeng Xu

Dr. Zhanpeng Xu


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2021 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Closed access
CJChangwei Jiao
Changwei Jiao
ZXZhanpeng Xu
Zhanpeng Xu
QBQiuwan Bian
Qiuwan Bian
EFErik Forsberg
Erik Forsberg
QTQin Tan
Qin Tan
Sailing HeSailing He
Sailing He

16 July 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ZXZhanpeng Xu
Zhanpeng Xu
YJYiming Jiang
Yiming Jiang
Sailing HeSailing He
Sailing He
In this work, we develop a multi-mode microscopic hyperspectral imager (MMHI) for the detection of biological samples in transmission imaging, reflection imaging and fluorescence mode. A hyperspectral image cube can be obtained with 5 μm spatial resolution and 3 nm spectral resolution through push-broom line scanning. To avoid possible shadows produced by the high magnification objective with a short working distance, two illumination patterns are designed to ensure the co-axiality of the illumination and detection. Three experiments for the detection of zebrafish and fingerprints and the classification of disaster-causing microalgae verify the good capability and functionality of the system. Based on the detected spectra, we can observe the impacts of β-carotene and melanin in zebrafish, hemoglobin in the fingertip, and chlorophyll in microalgae, respectively. Multi-modes can be switched freely according to the application requirement and characteristics of different samples, like transmission mode for the transparent/translucent sample, reflection mode for the opaque sample and fluorescence mode for the fluorescent sample. The MMHI system also has strong potential for the non-invasive and high-speed sensing of bio or clinical samples.

15 December 2020 in IEEE Photonics Journal
Verified
Journal Article
Open access
JDJi Du
Ji Du
XHXiaojian Hong
Xiaojian Hong
YWYuan Wang
Yuan Wang
ZXZhanpeng Xu
Zhanpeng Xu
WZWenyi Zhao
Wenyi Zhao
Sailing HeSailing He
Sailing He
In this paper, we experimentally demonstrate a 450-nm laser underwater optical wireless transmission system, in which a comprehensive investigation is made to show the significant performance improvement of the discrete Fourier transform spread discrete multi-tone (DFT-S DMT) as compared to the conventional quadrature amplitude modulation discrete multi-tone (QAM-DMT) modulation. DFT-S DMT outperforms QAM-DMT in terms of bit error rate (BER) performance due to low peak-to-average-power ratio (PAPR) and capability of counteracting high frequency fading in a band-limited underwater optical wireless communication (UOWC) system. In order to avoid signal-to-noise-ratio (SNR) degradation at fringe subcarriers, several zeros are padded at the edge of each block before DFT-S operation. The experimental results show the superiority of DFT-S DMT compared with QAM-DMT in different water environments, including turbidities, bubbles, and water flow. Data rates of ~16.16 Gbps and ~13.96 Gbps at a BER of 3.8×10 $^\text{-3}$ are achieved by 16-QAM DFT-S DMT and 16-QAM-DMT over a 5-m water channel, respectively, which indicates that capacity enhancement of ~2.2 Gbps is obtained by the DFT-S DMT. Meanwhile, over 3-dB receiver sensitivity improvement can always be achieved by the DFT-S DMT at the tested underwater transmission distances. Combined with adaptive bit-power loading, 20.04 Gbps over a 5-m "clear ocean" channel transmission with a single laser diode (LD) is demonstrated. For a 35-m water link, the distance-data rate product reaches 498.4 Gbps*m. To the best of our knowledge, both the data rate and distance-data rate product are the largest among all the results reported for a single visible LD. Aimed at high-speed deep ocean applications, the studies are promising for future UOWC research.

16 May 2020 in Sensors
Verified
Journal Article
Open access
PDF file
ZXZhanpeng Xu
Zhanpeng Xu
EFErik Forsberg
Erik Forsberg
YGYang Guo
Yang Guo
FCFuhong Cai
Fuhong Cai
Sailing HeSailing He
Sailing He
A novel light-sheet microscopy (LSM) system that uses the laser triangulation method to quantitatively calculate and analyze the surface topography of opaque samples is discussed. A spatial resolution of at least 10 μm in z-direction, 10 μm in x-direction and 25 μm in y-direction with a large field-of-view (FOV) is achieved. A set of sample measurements that verify the system′s functionality in various applications are presented. The system has a simple mechanical structure, such that the spatial resolution is easily improved by replacement of the objective, and a linear calibration formula, which enables convenient system calibration. As implemented, the system has strong potential for, e.g., industrial sample line inspections, however, since the method utilizes reflected/scattered light, it also has the potential for three-dimensional analysis of translucent and layered structures.