Yiming Jiang

Mr. Yiming Jiang


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 July 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ZXZhanpeng Xu
Zhanpeng Xu
YJYiming Jiang
Yiming Jiang
Sailing HeSailing He
Sailing He
In this work, we develop a multi-mode microscopic hyperspectral imager (MMHI) for the detection of biological samples in transmission imaging, reflection imaging and fluorescence mode. A hyperspectral image cube can be obtained with 5 μm spatial resolution and 3 nm spectral resolution through push-broom line scanning. To avoid possible shadows produced by the high magnification objective with a short working distance, two illumination patterns are designed to ensure the co-axiality of the illumination and detection. Three experiments for the detection of zebrafish and fingerprints and the classification of disaster-causing microalgae verify the good capability and functionality of the system. Based on the detected spectra, we can observe the impacts of β-carotene and melanin in zebrafish, hemoglobin in the fingertip, and chlorophyll in microalgae, respectively. Multi-modes can be switched freely according to the application requirement and characteristics of different samples, like transmission mode for the transparent/translucent sample, reflection mode for the opaque sample and fluorescence mode for the fluorescent sample. The MMHI system also has strong potential for the non-invasive and high-speed sensing of bio or clinical samples.

4 June 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YJYiming Jiang
Yiming Jiang
TZTie Zhang
Tie Zhang
Gaoxuan WANGGaoxuan WANG
Gaoxuan WANG
Sailing HeSailing He
Sailing He
A dual-gas photoacoustic spectroscopy (PAS) sensor based on wavelength modulation spectroscopy (WMS) was developed and experimentally demonstrated. Distributed feedback (DFB) laser diodes, emitting at 1512 and 1653 nm, were utilized as the excitation sources for the simultaneous measurement of NH3 and CH4, respectively. The PAS signal was excited by modulating the DFB laser at the first longitudinal resonant frequency of a cylindrical acoustic resonator. Absorption lines for NH3 and CH4 were simultaneously recorded during one frequency scan of the DFB lasers without using any optical switch. The interference of NH3 and CH4 on each other was investigated for accurate detection. The limits of detection (LoDs) of the PAS sensor for NH3 and CH4 for an integration time of 100 s were determined to be 0.1 and 0.3 ppm, respectively. The present PAS sensor provides a new scheme for multi-gas analysis with the advantages of cost-effectiveness, a simple structure and multi-wavelength operation.