Jae-Sung Bae

Prof. Jae-Sung Bae


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2009 in Journal of Mechanical Science and Technology
Verified
Journal Article
Closed access
PDF file
JBJae-Sung Bae
Jae-Sung Bae
JHJai-Hyuk Hwang
Jai-Hyuk Hwang
JPJung-Sam Park
Jung-Sam Park
DKDong-Gi Kwag
Dong-Gi Kwag

1 January 2014 in Shock and Vibration
Verified
Journal Article
Open access
PDF file
JBJae-Sung Bae
Jae-Sung Bae
JHJai-Hyuk Hwang
Jai-Hyuk Hwang
DKDong-Gi Kwag
Dong-Gi Kwag
JPJeanho Park
Jeanho Park
DIDaniel J. Inman
Daniel J. Inman
For a few decades, various methods to suppress the vibrations of structures have been proposed and exploited. These include passive methods using constrained layer damping (CLD) and active methods using smart materials. However, applying these methods to large structures may not be practical because of weight, material, and actuator constraints. The objective of the present study is to propose and exploit an effective method to suppress the vibration of a large and heavy beam structure with a minimum increase in mass or volume of material. Traditional tuned mass dampers (TMD) are very effective for attenuating structural vibrations; however, they often add substantial mass. Eddy current damping is relatively simple and has excellent performance but is force limited. The proposed method is to apply relatively light-weight TMD to attenuate the vibration of a large beam structure and increase its performance by applying eddy current damping to a TMD. The results show that the present method is simple but effective in suppressing the vibration of a large beam structure without a substantial weight increase.

1 January 2005 in Journal of Aircraft
Verified
Journal Article
Closed access
JBJae-Sung Bae
Jae-Sung Bae
JKJong-Yun Kim
Jong-Yun Kim
ILIn Lee
In Lee
YMYuji Matsuzaki
Yuji Matsuzaki
DIDaniel J. Inman
Daniel J. Inman

17 June 2014 in Smart Materials and Structures
Verified
Journal Article
Closed access
SKSeung-Hee Ko
Seung-Hee Ko
JBJae-Sung Bae
Jae-Sung Bae
JRJin-Ho Rho
Jin-Ho Rho

1 January 2018 in Shock and Vibration
Verified
Journal Article
Open access
PDF file
JBJae-Sung Bae
Jae-Sung Bae
JPJung-Sun Park
Jung-Sun Park
JHJai-Hyuk Hwang
Jai-Hyuk Hwang
JRJin-Ho Roh
Jin-Ho Roh
BPBong-Do Pyeon
Bong-Do Pyeon
JKJong-Hyuk Kim
Jong-Hyuk Kim
For a few decades, various methods of suppressing structural vibration have been proposed. The present study proposes and exploits an effective method of suppressing the vibration of cantilever plates similar to the solar panels of a satellite. Magnetically tuned mass dampers (mTMDs) are a tuned mass damper (TMD) with eddy current damping (ECD). We introduce the mTMD concept for the multimode vibration suppression of the cantilever plate. The design parameters of the mTMD are determined based on the parametric study of the theoretical four‐degree‐of‐freedom model, which was derived for a cantilever plate with TMDs. Two TMDs are optimized for the first bending mode and first torsion mode of the plate, and they are verified analytically and experimentally. To increase the damping performance of the TMDs, ECD is introduced. Its damping ratios are estimated analytically and verified experimentally.

24 November 2017 in Advanced Composite Materials
Verified
Journal Article
Closed access
JKJeong Sik Kwon
Jeong Sik Kwon
JKJin Sung Kim
Jin Sung Kim
SLSoo Yong Lee
Soo Yong Lee
JBJae-Sung Bae
Jae-Sung Bae
A comprehensive procedure for a mechanically fastened composite laminate joint (ASTM D5961 Proc. A, B) is demonstrated from fixture design to analysis of test results. The ASTM tests are applied to evaluate the standard laminate properties and the composite joints. Composite laminate mechanical joints were analyzed using the finite element method (FEM), and the results were compared to test results. A progressive failure analysis (PFA) was applied to the FEM to predict the overall failure behavior of the test specimens. Three laminate failure theories – maximum stress, maximum strain, and Tsai–Wu – were applied to the PFA to predict the test failure load, displacement and strength. The PFA method was suitable to predict the initial test range of test and maximum test load except for the excessive failure area.