Paolo Francesco Manicone

Prof. Paolo Francesco Manicone

Division of Oral Surgery and Implantology, Department of Head and Neck, Fondazione Policlinico Universitario A. Gemelli, IRCCS - School of Dentistry, Universita' Cattolica del Sacro Cuore, Roma
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2007 in Journal of Dentistry
Verified
Journal Article
Closed access
Paolo Francesco ManiconePaolo Francesco Manicone
Paolo Francesco Manicone
PIPierfrancesco Rossi Iommetti
Pierfrancesco Rossi Iommetti
LRLuca Raffaelli
Luca Raffaelli

1 June 2007 in Seminars in Ultrasound, CT and MRI
Verified
Journal Article
Closed access
FMFrancesco Molinari
Francesco Molinari
Paolo Francesco ManiconePaolo Francesco Manicone
Paolo Francesco Manicone
LRLuca Raffaelli
Luca Raffaelli
RRRenzo Raffaelli
Renzo Raffaelli
TPTommaso Pirronti
Tommaso Pirronti
LBLorenzo Bonomo
Lorenzo Bonomo

1 November 2009 in Recent Patents on Biotechnology
Verified
Journal Article
Closed access
PDF file
GMGiulio Maccauro
Giulio Maccauro
PIPierfrancesco Rossi Iommetti
Pierfrancesco Rossi Iommetti
FMFrancesco Muratori
Francesco Muratori
LRLuca Raffaelli
Luca Raffaelli
Paolo Francesco ManiconePaolo Francesco Manicone
Paolo Francesco Manicone
CFCarlo Fabbriciani
Carlo Fabbriciani
Tantalum is obtained from the minerals colombite, tantalite and euxenite. It is greyish silver, heavy and very hard. Tantalum does not react with body fluids and is used to make surgical equipment. Tantalum also does not irritate the body and is used to make surgical sutures as well as implants, such as artificial joints and cranial plates. Bone growth around tantalum covered by calcium phosphate is described by in vitro experimentations in vivo. Bioactive properties of porous tantalum have been recently developed. Porous tantalum consists of an interconnected porous structure with an average porosity diameter of approximately 400 μ m. Hollow spheres with nanometre-to-micrometer dimensions are widely used in different range of applications such as drug delivery carriers and bioreactors. Porous tantalum metal is currently used in orthopaedic for manufacturing of structural component for primary and revision total hip and knee replacements and, more recently, in spine surgery. Good clinical outcomes have been achieved especially in hip revision surgery, using tantalum implants, and promising short term follow up have been reported for knee revision surgery. Some patents for tantalum biomedical applications have been obtained and this article reviews various recent patents on this material. Many patents are developed on tantalum for biomedical application. This paper review some of them with particular interested for biomedical applications in orthopaedic and dentistry.

21 May 2020 in Experimental Biology and Medicine
Verified
Journal Article
Closed access
PDF file
Pier Carmine PassarelliPier Carmine Passarelli
Pier Carmine Passarelli
Edoardo RellaEdoardo Rella
Edoardo Rella
Paolo Francesco ManiconePaolo Francesco Manicone
Paolo Francesco Manicone
FGFranklin Garcia-Godoy
Franklin Garcia-Godoy
ADAntonio D’aDdona
Antonio D’aDdona
The novel Coronavirus pandemic defines a new risk for all dental practitioners, hygienists, and dental assistants. As an increasing number of dentists are now developing this disease, we wanted to provide some measures to manage this risk in the dental practice, by undergoing a review of the current literature. This minireview searches the literature for articles that both defined the infection risk in the dental practice and provided evidence on the efficacy of some procedures on reducing the infection risk. Several articles have already pointed out some necessary measures: fewer patients have to be admitted to the practice, a short triage should be carried out, and the appropriate measures of protection have to be used. On the basis of the literature collected, a short questionnaire and a flowchart is proposed to define the risk that each patient carries, and to appropriately adapt each procedure based on the patient’s risk. The literature is still limited on this subject, but on the basis of what is available, dental practices have to adapt to the situation in order to protect dental health professionals. Impact statement: Dentists have always been taught how to protect themselves and their patients from potential blood-borne pathogens, but the Coronavirus pandemic has brought a new unprecedented challenge to the world of dentistry; we therefore reviewed the literature to provide suggestions on how to accordingly change dental practice prevention.

1 July 2009 in International Journal of Immunopathology and Pharmacology
Verified
Journal Article
Open access
GMGiulio Maccauro
Giulio Maccauro
GBG. Bianchino
G. Bianchino
SSS. Sangiorgi
S. Sangiorgi
GMG. Magnani
G. Magnani
DMD. Marotta
D. Marotta
ASAlessandro Sgambato
Alessandro Sgambato
High purity alumina as well as zirconia ceramics have been widely used as orthopaedic implant biomaterials and dental devices displaying optimal, but sometimes exclusive, mechanical properties. In order to combine the advantages of alumina and zirconia ceramic materials different types of composites have been developed in which either zirconia is dispersed in an alumina matrix or vice versa. Orthopaedic and dental implant biomaterials are expected to be in contact with living tissues for a long period of time and their long term toxicity must be carefully evaluated. In this study we report the development of a high performance chromia-doped Zirconia Toughened Alumina (ZTA) material which displays promising mechanical properties in terms of hardness, strength and fracture toughness that make it suitable for prosthesis even for small joints. The long-term biocompatibility of this material was also evaluated, mainly in terms of DNA damage, mutagenicity and cancerogenetic potential in mammalian cells. The results obtained suggest that this new ZTA material does not display any long-term carcinogenic effect and it is suitable for biomedical applications from a cancerogenetic point of view. In conclusion, we report the development of a new chromia-doped ZTA material with interesting properties both from a mechanical and a biocompatibility point of view which warrant further studies on its suitability as a candidate biomaterial for orthopaedic implants and dental devices.

1 May 2010 in Journal of Oral and Maxillofacial Surgery
Verified
Journal Article
Closed access
LLLuca Landi
Luca Landi
Paolo Francesco ManiconePaolo Francesco Manicone
Paolo Francesco Manicone
SPStefano Piccinelli
Stefano Piccinelli
ARAlessandro Raia
Alessandro Raia
RRRoberto Raia
Roberto Raia