Vladimíra Volná

Dr. Vladimíra Volná

Czech hydrometeorological Institute
+1
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 May 2020 in Atmosphere
Verified
Journal Article
Open access
PDF file
RSRadim Seibert
Radim Seibert
INIrina Nikolova
Irina Nikolova
VVVladimíra Volná
Vladimíra Volná
BKBlanka Krejci
Blanka Krejci
DHDaniel Hladký
Daniel Hladký
This article focuses on the source apportionment of air pollution in a specific northeastern part of the Czech Republic. The research area, located around the city of Třinec, is significantly affected by a complex spectrum of air pollution sources, including local residential heating (coal and wood burning), heavy industry (mainly iron and steel production), road traffic, and regional and long-range air pollution transport from the nearby cities, Poland, and other countries. The main pollution sources contributing to the total concentration of fine suspended particles (PM2.5) were evaluated on the basis of the measurements at three sites and on subsequent positive matrix factorization modeling. The six major air pollution factors were identified, and their relative and absolute contributions were quantified. The result of the study is that the most important current task of air protection is to reduce the residential emissions from solid fuels, which are responsible for approximately 50–60% of PM2.5 concentration, followed by the regional primary and secondary aerosol sources (up to 40% of the total PM2.5 aerosol mass). Lower contributions have been identified in the case of resuspended mineral and biogenic particles (15–20%), long-range (trans-European) air pollution transport (up to 10%), and heavy industry (up to 10% in the most affected location). A detailed discussion has been provided considering specific regional EC (elemental carbon)–OC (organic carbon) relations in the region with traditional coal-burning for household heating which complicate the interpretation of the PMF (Positive Matrix Factorization) results, especially due to the interference between the traffic, residential heating, and biogenic aerosol factors.

12 May 2020 in Atmosphere
Verified
Journal Article
Open access
PDF file
VVVladimíra Volná
Vladimíra Volná
DHDaniel Hladký
Daniel Hladký
This article assessed the links between PM10 pollution and meteorological conditions over the Czech-Polish border area at the Třinec-Kosmos and Věřňovice sites often burdened with high air pollution covering the years 2016–2019. For this purpose, the results of the measurements of special systems (ceilometers) that monitor the atmospheric boundary layer were used in the analysis. Meteorological conditions, including the mixing layer height (MLH), undoubtedly influence the air pollution level. Combinations of meteorological conditions and their influence on PM10 concentrations also vary, depending on the pollution sources of a certain area and the geographical conditions of the monitoring site. Gen1erally, the worst dispersion conditions for the PM10 air pollution level occur at low air temperatures, low wind speed, and low height of the mixing layer along with a wind direction from areas with a higher accumulation of pollution sources. The average PM10 concentrations at temperatures below 1 °C reach the highest values on the occurrence of a mixing layer height of up to 400 m at both sites. The influence of a rising height of the mixing layer at temperatures below 1 °C on the average PM10 concentrations at Třinec-Kosmos site is not as significant as in the case of Věřňovice, where a difference of several tens of µg·m−3 in the average PM10 concentrations was observed between levels of up to 200 m and levels of 200–300 m. The average PM10 hourly concentrations at Třinec-Kosmos were the highest at wind speeds of up to 0.5 m·s−1, at MLH levels of up to almost 600 m; at Věřňovice, the influence of wind speeds of up to 2 m·s−1 was detected. Despite the fact that the most frequent PM10 contributions come to the Třinec-Kosmos site from the SE direction, the average maximum concentration contributions come from the W–N sectors at low wind speeds and MLHs of up to 400 m. In Věřňovice, regardless of the prevailing SW wind direction, sources in the NE–E sector from the site have a crucial influence on the air pollution level caused by PM10.

17 February 2022 in Atmosphere
Verified
Journal Article
Open access
PDF file
VVVladimíra Volná
Vladimíra Volná
DHDaniel Hladký
Daniel Hladký
RSRadim Seibert
Radim Seibert
BKBlanka Krejci
Blanka Krejci
The article is occupied with the evaluation of the transboundary transport of pollutants in the Czech–Polish border region (between the Moravian-Silesian region and the Silesian Voivodeship) in Central Europe. It focuses on the evaluation of concentrations of benzo[a]pyrene (BaP) and suspended particles of PM10 depending on meteorological conditions, especially wind direction. The whole area of interest is heavily affected with air pollution of BaP and PM10. Limits of BaP and PM10 are still exceeded. Annual concentrations of benzo[a]pyrene are even several times higher than the value of its annual limit. The elaboration follows the results of the Czech–Polish project “Air Silesia”, which dealt with air pollution and the transboundary transport of pollutants in this area and took place in 2010 to 2013. Within this project, a higher transport of pollutants from Poland to the Czech Republic was established. The evaluation of the dependences of PM10 concentrations is based on hourly and daily data of PM10 and hourly data of meteorological quantities. To assess the dependences of daily BaP and PM10 concentrations, a methodology for evaluating daily types of wind direction was implemented into the processing. The results confirm that the problem of above-limit concentrations of BaP and PM10 in the Moravian-Silesian Region in the Czech Republic and the Silesian Voivodeship in Poland remains. The article confirms there is a higher transport of PM10 concentrations from Poland to the Czech Republic in the area of interest. Higher transport in the same direction is also predicted for daily concentrations of benzo[a]pyrene, although this cannot be clearly confirmed due to the lack of more detailed and identifiable data.

13 October 2021 in Environments
Verified
Journal Article
Open access
PDF file
RSRadim Seibert
Radim Seibert
INIrina Nikolova
Irina Nikolova
VVVladimíra Volná
Vladimíra Volná
BKBlanka Krejci
Blanka Krejci
DHDaniel Hladký
Daniel Hladký
The results of air quality monitoring show significantly increased concentrations of polycyclic aromatic hydrocarbons (PAH) and arsenic in the area located near the town of Kladno in Central Bohemia, Czech Republic. The region of interest is historically associated with coal mines and steelworks. Source apportionment using the method of Positive Matrix Factorization (PMF) at three sites has been used to try to explain the reasons of the increased PM2.5, benzo[a]pyrene, and arsenic concentrations in the ambient air. Based on the PMF analysis, nine factors explaining the atmospheric aerosol mass have been identified. The PMF results showed that most of the aerosol mass originated from residential heating (about one third of PM2.5), both primary particles and secondary organic aerosols induced by road traffic (up to approximately 25%), soil and other mineral dust (about 15%), secondary inorganic aerosol ammonium sulfate (up to 16%), ammonium nitrate (up to 14%) and other sulfates (up to 9%). The main source of arsenic and benzo[a]pyrene was residential heating, which accounted for two-thirds and 80% of their total mass, respectively. The results have pointed to the most important measures for effective air quality protection in the area of interest: replacing coal fuel and old boilers used for residential heating in order to reduce arsenic and PAH emissions and mitigate sources of secondary particles precursors to decrease PM concentrations.

19 July 2023 in Atmospheric Environment
Verified
Journal Article
Closed access
EMEva Martinková
Eva Martinková
YKYulia V.ERban Kochergina
Yulia V.ERban Kochergina
OŠOndřej Šebek
Ondřej Šebek
RSRadim Seibert
Radim Seibert
VCVladislav Chrastný
Vladislav Chrastný
AKArnošt Komárek
Arnošt Komárek

30 January 2024 in Atmosphere
Verified
Journal Article
Open access
PDF file
VVVladimíra Volná
Vladimíra Volná
RSRadim Seibert
Radim Seibert
DHDaniel Hladký
Daniel Hladký
BKBlanka Krejci
Blanka Krejci
This contribution deals with the assessment of air pollution caused by atmospheric aerosol particulate matter fraction PM10 and benzo[a]pyrene (BaP) in the urban agglomeration of Ostrava, located in the Czech Republic in Central Europe. The motivation for this research was the need to identify the sources of air pollution in the area, particularly in locations where the contribution of different sources to concentrations of pollutants of concern has not been elucidated yet. In this study, source apportionment in the vicinity of the industrial hot spot was performed by statistically evaluating measured pollutant concentrations as a function of meteorological variables and using the Positive Matrix Factorization (PMF) receptor model. A significant methodological innovation and improvement over previous assessments was the higher monitoring resolution of benzo[a]pyrene, with samples collected at three-hour intervals instead of the standard 24 h collection period. The key findings indicate that in the cold part of the year, secondary particles—specifically sulfates and ammonium nitrates—were responsible for the most significant portion of PM10 air pollution throughout the area of interest. The contribution of these particles ranged from one-third to two-fifths of the total concentration, except at the industrial site of Ostrava–Radvanice (TORE), where they accounted for approximately one-fifth of the measured pollution concentration level. Emissions from individual household heating were identified as the main source of this type of pollution. With regards to benzo[a]pyrene air pollution, this study found that in the whole area of interest, except for the Ostrava–Radvanice site, it mainly originated from individual heating with coal (90%). In contrast, at the Ostrava–Radvanice site, two-thirds of the benzo[a]pyrene pollution came from the premises of Liberty Ostrava a.s., primarily from coke production, and less than one-third came from local domestic heating. This study also determined the spatial extent of the occurrence of extremely high benzo[a]pyrene concentrations (above 5 ng/m3), which are estimated to affect nearly 10,000 inhabitants. The results confirm that the data from the TORE station are only representative of its immediate surroundings and are not applicable to the assessment of air quality and causes of air pollution in the whole city of Ostrava or the urban area of Ostrava–Radvanice as a whole. After years of research, these findings provide the Ministry of the Environment of the Czech Republic and the government with an accurate basis for implementing measures to address the identified pollution sources in the area of interest. The success of this study was made possible by the adoption of a more detailed sampling approach, which involved a resolution of 3 h instead of 24 h. This methodological improvement is a significant finding and will be useful for future source apportionment studies.