Daniel Ulises Campos-Delgado

Prof. Daniel Ulises Campos-Delgado

Universidad Autonoma de San Luis Potosi
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2010 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Daniel Ulises Campos-DelgadoDaniel Ulises Campos-Delgado
Daniel Ulises Campos-Delgado
DED. R. Espinoza-Trejo
D. R. Espinoza-Trejo
In this paper, the detection and isolation of open-switch faults in induction motor (IM) drives are addressed from a model-based perspective. Residuals are synthesized by using nonlinear observers followed from a directional characterization. First, it is observed that the IM model can be written in a recurrent decoupled structure by taking the stator currents and mechanical velocity as outputs. In this way, residuals can be insensitive to load torque and operating conditions, and simultaneous faults can be addressed. A pulsewidth modulation three-phase inverter is studied as power actuator for the IM. Hence, in order to isolate faults related to the six switching devices, a directional residual evaluation in the -frame is employed. Hence, three residuals are constructed to isolate the faulty switches. The ideas presented in this paper are validated experimentally in a test bench of 1-hp IM under single and simultaneous faults.

1 March 2008 in IET Electric Power Applications
Verified
Journal Article
Closed access
Daniel Ulises Campos-DelgadoDaniel Ulises Campos-Delgado
Daniel Ulises Campos-Delgado
DED.R. Espinoza-Trejo
D.R. Espinoza-Trejo
EPE. Palacios
E. Palacios
A survey on fault-tolerant control is presented for variable speed drives (VSD), mainly addressing DC and induction motors. Thus, fault diagnosis, accommodation and hardware reconfiguration are reviewed with application to VSD. First, the most common fault scenarios in these electrical machines are described. These conditions are analysed, and their implications and mathematical modelling are discussed. Next, the fault diagnosis strategies based on signal processing, model-based techniques and artificial intelligence are reviewed. Moreover, the diverse hardware reconfiguration schemes of power actuators with semiconductor failures are detailed. A key piece in any VSD is the control algorithm, which can be severely affected in a fault condition. Finally, the fault accommodation schemes suggested so far in the literature are illustrated.

1 September 2004 in Control Engineering Practice
Verified
Journal Article
Closed access
ERE. Ruiz-Velázquez
E. Ruiz-Velázquez
RFR. Femat
R. Femat
Daniel Ulises Campos-DelgadoDaniel Ulises Campos-Delgado
Daniel Ulises Campos-Delgado

14 November 2023 in npj Precision Oncology
Verified
Journal Article
Open access
PDF file
Raquel LeonRaquel Leon
Raquel Leon
Himar FabeloHimar Fabelo
Himar Fabelo
SOSamuel Ortega
Samuel Ortega
Ines A. Cruz-GuerreroInes A. Cruz-Guerrero
Ines A. Cruz-Guerrero
Daniel Ulises Campos-DelgadoDaniel Ulises Campos-Delgado
Daniel Ulises Campos-Delgado
Gustavo CallicoGustavo Callico
Gustavo Callico
Brain surgery is one of the most common and effective treatments for brain tumour. However, neurosurgeons face the challenge of determining the boundaries of the tumour to achieve maximum resection, while avoiding damage to normal tissue that may cause neurological sequelae to patients. Hyperspectral (HS) imaging (HSI) has shown remarkable results as a diagnostic tool for tumour detection in different medical applications. In this work, we demonstrate, with a robust k-fold cross-validation approach, that HSI combined with the proposed processing framework is a promising intraoperative tool for in-vivo identification and delineation of brain tumours, including both primary (high-grade and low-grade) and secondary tumours. Analysis of the in-vivo brain database, consisting of 61 HS images from 34 different patients, achieve a highest median macro F1-Score result of 70.2 ± 7.9% on the test set using both spectral and spatial information. Here, we provide a benchmark based on machine learning for further developments in the field of in-vivo brain tumour detection and delineation using hyperspectral imaging to be used as a real-time decision support tool during neurosurgical workflows.

1 July 2013 in IET Electric Power Applications
Verified
Journal Article
Open access
PDF file
Daniel Ulises Campos-DelgadoDaniel Ulises Campos-Delgado
Daniel Ulises Campos-Delgado
JSJOSE ANGEL PECINA SANCHEZ
JOSE ANGEL PECINA SANCHEZ
DEDiego Rivelino Espinoza‐Trejo
Diego Rivelino Espinoza‐Trejo
EAEdgar Román Arce‐Santana
Edgar Román Arce‐Santana
This study addresses the problem of detection and isolation of open‐switch faults in voltage source inverters by processing the stator current measurements. First, the resulting post‐fault trajectories for the stator currents are analytically derived for single and concurrent faults (21 classes) by using Fourier series. This analysis motivated the proposed approach, which is based on the resulting pattern of the stator currents in the dq ‐frame after a fault, where a histogram of the trajectory is calculated by dividing the plane in 24 equally spaced sectors. From the calculated histogram, a distinctive signature is associated to each fault trajectory in the dq ‐plane. Single and double faults in the power semi‐conductors are analysed that all provide linearly independent signatures for fault isolation. The proposed isolation methodology is independent of the load torque (system disturbance), supply frequency and only requires the information of the stator currents. Furthermore, since the isolation stage is focused on the angle of the current trajectories in the dq ‐plane, open‐ and closed‐loop configurations of a variable speed drive can be simultaneously handled. Experimental results with a test bench of 3/4 HP induction motor under single and concurrent faults validated the proposed methodology.

1 May 2013 in IET Power Electronics
Verified
Journal Article
Open access
PDF file
DEDiego Espinoza
Diego Espinoza
Daniel Ulises Campos-DelgadoDaniel Ulises Campos-Delgado
Daniel Ulises Campos-Delgado
GBGuillermo Bossio
Guillermo Bossio
EBErnesto Bárcenas
Ernesto Bárcenas
JHJosé Enrique Hernández‐Díez
José Enrique Hernández‐Díez
LLLuis Felipe Lugo‐Cordero
Luis Felipe Lugo‐Cordero
In this study, a new model‐based fault detection and isolation (FDI) strategy is proposed for field‐oriented control (FOC) induction motor (IM) drives. Actuator faults are addressed, and specifically, single open‐circuit faults are considered in this study. The residual signals are synthesised by taking the resulting closed‐loop dynamics when a FOC strategy is applied, that is, the residuals are referenced to the synchronous reference frame ( dq e ‐coordinates), which are generated by using a bank of variable structure observers to obtain a robust FDI scheme. Thus, subsystems sensitive to a specific fault, but decoupled from other faults are obtained in a natural way, where only two stator currents and the mechanical position are required for fault isolation purposes. Residual evaluation is carried out in the stator reference frame ( dq ‐coordinates) for the IM model, where the residual direction (angle) is employed to isolate a fault in each one of the six power switches in a voltage source inverter. In addition, the observer FDI scheme can be combined with a fault re‐configuration strategy in order to improve the reliability of the motor drive. Experimental results are illustrated for a three‐phase 3/4 HP IM drive at different reference frequencies and load torques with single open‐circuit faults that verify the ideas presented in this work.