Alex Vadati

Dr. Alex Vadati


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2010 in Biochemical and Biophysical Research Communications
Verified
Journal Article
Closed access
CKCarly M. Kemmis
Carly M. Kemmis
AVAlex Vadati
Alex Vadati
HWHolly E. Weiss
Holly E. Weiss
DWDiane R. Wagner
Diane R. Wagner

1 July 2017 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
PDF file
ISIbrahim Seven
Ibrahim Seven
AVAlex Vadati
Alex Vadati
IPIben Bach Pedersen
Iben Bach Pedersen
AVAnders Vestergaard
Anders Vestergaard
JHJesper Hjortdal
Jesper Hjortdal
WDWilliam Dupps
William Dupps
PURPOSE: Computational analyses were performed to quantify and directly compare the biomechanical impact of flapless and flap-based procedures in a series of patients undergoing small incision lenticule extraction (SMILE) in one eye and flap-based femtosecond lenticule extraction in the other.METHODS: Tomographic data from 10 eyes of 5 patients undergoing femtosecond laser refractive lenticule extraction for myopic astigmatism with or without a stromal flap (femtosecond lenticule extraction in one eye, SMILE in the contralateral eye) were used to generate computational models. Inverse finite element analyses were performed at physiologic intraocular pressure followed by forward analyses at elevated intraocular pressure to assess corneal displacement and stress under differential loading. Case-specific treatment settings were incorporated. Preoperative material constants were obtained through inverse finite element analyses, and the surgically induced change in fiber stiffness within each flap was determined by minimization of the error between the simulated and actual 6-month topographic outcomes.RESULTS: Flap-based procedures produced a 49% (range: 2% to 87%) greater mean reduction in effective stromal collagen fiber stiffness within the flap region than contralateral SMILE cases. Lower stresses and deformations were observed within the residual stromal bed in SMILE cases than in flap-based cases. Stromal bed displacements and stresses were more affected by a loading increase in flap-based eyes than flapless eyes.CONCLUSIONS: Intrastromal flapless procedures had less impact on anterior stromal collagen mechanics and resulted in lower stromal bed displacements and stresses than flap-based procedures in contralateral eyes. However, biomechanical impact varied widely between individuals and this reinforces the need for individualized assessment of ectasia risk.[J Refract Surg.2017;33(7):444–453].

1 November 2016 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
ISIbrahim Seven
Ibrahim Seven
AVAlex Vadati
Alex Vadati
VSVinicius Silbiger De Stefano
Vinicius Silbiger De Stefano
RKRonald R. Krueger
Ronald R. Krueger
WDWilliam Dupps
William Dupps
Purpose: To assess the predictive accuracy of simulation-based LASIK outcomes. Methods: Preoperative and 3-month post-LASIK tomographic data from 20 eyes of 12 patients who underwent wavefront-optimized LASIK for myopia were obtained retrospectively. Patient-specific finite element models were created and case-specific treatment settings were simulated. Simulated keratometry (SimK) values and the mean tangential curvature of the central 3 mm (Kmean) were obtained from the anterior surfaces of the clinical tomographies, and computational models were compared. Correlations between Kmean prediction error and patient age, preoperative corneal hysteresis (CH), and corneal resistance factor (CRF) were assessed. Results: The mean difference for Kmean between simulated and actual post-LASIK cases was not statistically significant (−0.13 ± 0.36 diopters [D], P = 0.1). The mean difference between the surgically induced clinical change in Kmean and the model-predicted change was −0.11 ± 0.34 D (P = 0.2). Kmean prediction error was correlated to CH, CRF, and patient age (r = 0.63, 0.53, and 0.5, respectively, P < 0.02), and incorporation of CH values into predictions as a linear offset increased their accuracy. Simulated changes in Kmean accounted for 97% of the variance in actual spherical equivalent refractive change. Conclusions: Clinically feasible computational simulations predicted corneal curvature and manifest refraction outcomes with a level of accuracy in myopic LASIK cases that approached the limits of measurement error. Readily available preoperative biomechanical measures enhanced simulation accuracy. Patient-specific simulation may be a useful tool for clinical guidance in de novo LASIK cases.

1 April 2009 in Mechanics Research Communications
Verified
Journal Article
Closed access
AVAlex Vadati
Alex Vadati
GRGholamreza Rouhi
Gholamreza Rouhi


1 February 2014 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
AVAlex Vadati
Alex Vadati
SWS. Walscharts
S. Walscharts
IJIlse Jonkers
Ilse Jonkers
José Manuel García-AznarJosé Manuel García-Aznar
José Manuel García-Aznar
JSJ. Vander Sloten
J. Vander Sloten
GLG.H. van Lenthe
G.H. van Lenthe