Umar Khayam

Dr. Umar Khayam


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 April 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
UKUmar Khayam
Umar Khayam
AZArpan Zaeni
Arpan Zaeni
KBKevin Marojahan Banjar-Nahor
Kevin Marojahan Banjar-Nahor
DHDeny Hamdani
Deny Hamdani
NSNgapuli I Sinisuka
Ngapuli I Sinisuka
Laurent CanaleLaurent Canale
Laurent Canale
In 2019, Indonesia’s electricity consumption exceeded 278 TWH, or about 1.08 MWh/capita. This value shows a considerable increase in electricity consumption which has doubled in just a decade. Previous studies have shown that the proportion of electricity consumption used for lighting needs is correlated to the country’s GDP. This is generally around 20 to 50% of electricity production but can go up to 86% in the case of Tanzania. Indonesia is the 4th country in the world in terms of population and its lighting market as well as its lighting-related energy consumption has a strong impact on several levels: societal, environmental but also economic and energy. Having a knowledge of the lamps used by the Indonesian people is therefore particularly interesting and important, in particular in the context which presents a great societal diversity but also in a context of energy saving. Indonesia is an archipelagic country made up of 5 large islands and over 17,000 small islands with widely varying levels of population density. This island geography leads Indonesia to face challenges in the distribution and production of electrical energy, which affects the use of lamps in various types of regions. The overview of this study was done by collecting data from various sources, especially BPS (Biro Pusat Statistik/Statistic Center Bureau of Indonesia), CLASP (an NGO for clean energy), the Ministry of Energy and Mineral Resources of Indonesia (ESDM), PLN (Indonesian Electrical Company), etc. The data obtained from these sources provides several descriptions of general lighting conditions in Indonesia viewed from several angles, such as growth of lamp market, use of lamp types, percentage of use of lamps with energy saving (ESL), etc. Considering that Indonesia has various regional characteristics, in this study, the survey of a total of 394 respondents was conducted on the use of lamps by creating regional categories based on electrical conditions, power consumption, and electricity per capita, among others. The categories of areas observed fall into 5 types based on their population and geography: large cities, small towns, rural/village areas, islands and remote areas. The results of compiling data from these various sources show that the types of lamps used by Indonesians follow the lighting trend in the world. The use of LED lamps has a utilization percentage of around 52%, much higher than other types of lamps such as CFL, fluorescent or incandescent. Based on the survey conducted, it is known that the widely used LED power is between 1 and 10 watts with a usage time of 8 to 12 h per day. In the next few years, it is estimated that the use of LEDs in Indonesia will increase as the government has prepared various regulations and policies related to energy saving, one of which relates to lighting.
1

1 February 2019 in TELKOMNIKA (Telecommunication Computing Electronics and Control)
Verified
Journal Article
Open access
PDF file
KBKarel Octavianus Bachri
Karel Octavianus Bachri
UKUmar Khayam
Umar Khayam
BSBambang Anggoro Soedjarno
Bambang Anggoro Soedjarno
ASArwin Datumaya Wahyudi Sumari
Arwin Datumaya Wahyudi Sumari
AAAdang Suwandi Ahmad
Adang Suwandi Ahmad
Cognitive artificial-intelligence for doernenburg dissolved gas analysis interpretation

1 August 2019 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
AZA Zaeni
A Zaeni
TKT Kasnalestari
T Kasnalestari
UKUmar Khayam
Umar Khayam
The important thing to do after we detect the existence of partial discharges inside an isolation system is signal processing. One form of signal processing that needs to be carried out on the generated waveform is denoising or noise removal from the wave obtained. In this study, an experiment will be conducted to denounce partial discharge waves using Wavelet and Threshold transformations. Wavelet transformation is applied in various levels then we compare the best denomination while denoisation using Threshold is applied using Soft Threshold and Hard Threshold.

6 April 2018 in MATEC Web of Conferences
Verified
Journal Article
Open access
RARahayu
Rahayu
GAG.T. Anuraga
G.T. Anuraga
HPH. Prasetia
H. Prasetia
UKUmar Khayam
Umar Khayam
Partial Discharge (PD) is one of the causes of insulation deteriorisation mode and impacts on the reliability of high voltage equipment. Therefore, PD measurement is used for diagnostic technique of high voltage equipment. Diagnostic output of high voltage equipment contain information about PD type, PD cause, PD location and PD severity. after identification, a proper preventive maintenance pattern can be performed. Therefore PD pattern recognition system is very important on PD diagnostic system to recognize the PD pattern and determine the level of hazard that occurs in specimen object or high voltage equipment‥ In this paper, PD pattern recognition system is designed with fractal geometry approach and support vector machine (SVM) algorithm. The coding and programming of graphical user interface of the application is done. Each PD type and hazard level on various insulating materials (solid, liquid and gas) have the dimensions of the fractal and the lacunarity. The type of PD (void, corona) and its danger level (bad, fair and good) can be identified with the support vector machine (SVM)

1 October 2017 in Proceeding of the Electrical Engineering Computer Science and Informatics
Verified
Journal Article
Open access
PDF file
UKUmar Khayam
Umar Khayam
FFFendi Imam Fatoni
Fendi Imam Fatoni
Partial discharge (PD) detection by detecting the released energy in the form of electromagnetic (EM) wave during discharge using Ultra-High Frequency (UHF) antenna is one of the methods to determine insulation system quality of power apparatus. The main advantage of UHF PD detection system by using antenna are the capability to detect PD signal without firstly shut down the power apparatus. Therefore, the PD measurement system based on EM wave induced by PD detected by the sensor is needed. First, the sensors which be able to detect PD induced EM wave in ultra wide band need to be designed and manufactured. Second, the characteristics of PD induced EM wave measured by the sensors need to be investigated. This paper deals with measurement of PD induced EM wave by using loop antenna. The results show that the further the distance of loop antenna to PD source is, the lower Vpp is. This is due to EM wave attenuation. At the distance 225 cm from PD source, Vpp of PD is equal to Vpp of the background noise (BGN). Therefore, the maximum distance of the loop sensor to PD source is 225 cm.

10 April 2025 in Jurnal Informatika dan Teknik Elektro Terapan
Verified
Journal Article
Open access
PDF file
FNFarradita Nugraha
Farradita Nugraha
UKUmar Khayam
Umar Khayam
TRTaufik Rhamdhani
Taufik Rhamdhani
Antena merupakan suatu sensor yang dapat digunakan sebagai alat mendeteksi adanya partial discharge pada GIS (Gas Insulated Switchgear. Deteksi partial discharge pada GIS dilakukan untuk mengetahui kondisi dari isolasi pada peralatan tegangan tinggi tersebut. Sensor antenna diatur pada range 300 MHz-3 GHz atau pada Ultra High Frekuensi (UHF), agar sesuai dengan sinyal gelombang elektromagnetik pada GIS. Dalam pembuatan antenna sebagai sensor, hal pertama yang perlu dilakukan adalah melakukan simulasi pada antenna menggunakan aplikasi gambar 3 dimensi, sehingga didapatkan ukuran antenna terbaik dengan bandwidth yang lebar serta nilai return loss yang kecil. Setelah dilakukan perubahan pada parameter panjang maupun lebar antenna dipole, maka didapatkan hasil simulasi terbaik pada bandwidth dan return loss, yaitu ketika dilakukan pengaturan pada perubahan panjang antenna tersebut dengan ukuran 35 x 40 mm dengan bandwidth sebesar 956 MHz dan return loss sebesar -22,41 dB.