Although magnetic neural stimulation has many advantages over electrical neural stimulation, its main disadvantages are higher energy requirement and poor stimulation selectivity. The orientation and location of the coil with respect to the stimulation site play a critical role in determining the stimulation threshold and stimulation selectivity. Utilizing numerical simulations in this work, we optimized the design parameters, orientation, and positioning of magnetic coils with respect to the peripheral nerve for improved stimulation efficacy. Specifically, we investigated different orientations and positions of the figureof- eight coils for neural stimulation of the rat sciatic nerve. We also examined the effect of coil design parameters (number of layers and turns) and different coil electrical configurations (opposite vs. same direction of coil currents and series vs. parallel coil connections) on the stimulation threshold. We leveraged the multi-resolution impedance method and a heterogeneous multifascicular anatomical model of rat sciatic nerve to explore the possibility of selective stimulation as well. Neural excitation of a nerve fiber was implemented by an equivalent cable model and Frankenhaeuser-Huxley equations using NEURON software. Results suggest that inter-fascicular selectivity could be achieved by properly orienting and positioning the coil with respect to the nerve. Further, by orienting the figure-of-eight coil at an angle of 90° and 6 mm offset, we could switch between primarily activating one fascicle (and barely activating the other) and reversing those roles by merely switching the current direction in the two coils of the figure-of-eight coil.
12 April 2019 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Current truncating circuit designs used in some controllable pulse width transcranial magnetic stimulation systems can be adapted for use with the peripheral nervous system. Such a scaled-down stimulator produces neuromuscular activation using less stimulus energy than described in previous reports of sciatic nerve stimulation. To evaluate the energy reductions possible with current truncation, we performed six in vivo experiments in rats where the magnetic stimulating coil abutted the sciatic nerve. We used electromyographic data to quantify neuromuscular response, with a criterion level of 20%-of-maximum to indicate a useful level of neuromuscular activation. The energy required to evoke this criterion response from muscles innervated by the sciatic nerve was reduced by approximately 34% from 10.7J with a stimulus waveform lasting 300 ${\mu }\text{s}$ to 7.1J with a waveform lasting 50 ${\mu }\text{s}$ . In water, the 300 ${\mu }\text{s}$ pulse heated the coil by 0.30°C whereas the 50 ${\mu }\text{s}$ pulse heated the coil by 0.15°C. Truncated-waveform magnetic stimulation systems can be used in basic research and clinical applications not requiring rapidly pulsed stimuli. An example of such a clinical application is left vagus nerve stimulation, a treatment that is reported to reduce epileptic partial-onset seizures.
This paper describes the semester group project for the North Carolina State University Biomedical Instrumentation class, BME/ECE 522 from the spring semester of 2013. The topic of sleep, and more specifically Rapid Eye Movement (REM) during sleep, was selected by the group, and from that, the electrooculogram was chosen for its particular focus on nonintrusive eye movement detection. Knowledge of the theory behind electrooculography is widely available; however, the consumer market does not favor the electrooculogram, instead preferring electroencephalography or other approaches such as inferring sleep stages from motion. This paper presents the stages involved in our process of understanding the theory and applying it to create a prototype electrooculogram sleep mask. Our sleep mask obtains electrical recordings from the face and, following analog filtering, records this signal via an analog to digital converter. Later, a MATLAB algorithm uses Fourier analysis on this data to determine when REM sleep occurred. We observed that REM detection in the recordings from this prototype sleep mask correlate well with a commercial electroencephalogram device: the Zeo sleep monitor. The results show that the electrooculogram is a promising approach to REM sleep detection.
Microelectrode arrays are one of the most important tools for advancing our knowledge of biological neural systems. Thorough characterization of microelectrode arrays helps designers optimize neural interface circuits and systems as well as microelectrodes themselves, which in turn enables a better understanding of nervous systems. Noise and impedance of electrode arrays are important for determining specifications for neural interface electronics, but data are largely lacking in the literature. This work presents engineering-oriented characterizations of the commonly used SIROF Utah Electrode Array. The study demonstrates a strong correlation between noise and impedance, and finds a significant increase in both noise and impedance in vivo versus in vitro. We also observe an increase in low-frequency (<; 1 kHz) noise in vivo that is consistent with biological noise reported elsewhere.