28 November 2018 in IEEE Transactions on Antennas and Propagation
ERErik Saturnino Gamez Rodriguez
Erik Saturnino Gamez Rodriguez
5 March 2018 in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
ERErik Saturnino Gamez Rodriguez
Erik Saturnino Gamez Rodriguez
+6
A cortical visual prosthetic system bypasses the components of the visual pathway, which may be damaged due to injury or disease, by directly stimulating the visual cortex; therefore, cortical visual prostheses promise the capability of restoring a form of vision to patients who cannot benefit from other types of visual neural stimulators. A high data rate, multielectrode, implantable device, such as that utilized for a cortical visual prosthesis, requires continuous power provided by an external telemetry unit, which is nonnegligible, given the number of stimulating electrodes and the stimulation rate necessary to avoid flickering visual percepts. This aspect motivates the need to develop models and methods that aid the development of such devices by assessing their compliance with electromagnetic safety standards. In this paper, the electromagnetic safety assessment of a cortical visual prosthetic system is considered, and the solutions employed to numerically treat the computational complexities associated with it are discussed. The specifics of the implementation of an actual visual cortical implant are discussed, and the parameters of such an implant are used as a test case to determine whether IEEE and ICNIRP electromagnetic standards are met in what can be considered a typical embodiment of the prosthesis. Results show that, for the considered implant, such a system meets IEEE and ICNIRP safety standards, thus enabling further development of similar neurorehabilitative devices.
17 November 2020 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Although magnetic neural stimulation has many advantages over electrical neural stimulation, its main disadvantages are higher energy requirement and poor stimulation selectivity. The orientation and location of the coil with respect to the stimulation site play a critical role in determining the stimulation threshold and stimulation selectivity. Utilizing numerical simulations in this work, we optimized the design parameters, orientation, and positioning of magnetic coils with respect to the peripheral nerve for improved stimulation efficacy. Specifically, we investigated different orientations and positions of the figureof- eight coils for neural stimulation of the rat sciatic nerve. We also examined the effect of coil design parameters (number of layers and turns) and different coil electrical configurations (opposite vs. same direction of coil currents and series vs. parallel coil connections) on the stimulation threshold. We leveraged the multi-resolution impedance method and a heterogeneous multifascicular anatomical model of rat sciatic nerve to explore the possibility of selective stimulation as well. Neural excitation of a nerve fiber was implemented by an equivalent cable model and Frankenhaeuser-Huxley equations using NEURON software. Results suggest that inter-fascicular selectivity could be achieved by properly orienting and positioning the coil with respect to the nerve. Further, by orienting the figure-of-eight coil at an angle of 90° and 6 mm offset, we could switch between primarily activating one fascicle (and barely activating the other) and reversing those roles by merely switching the current direction in the two coils of the figure-of-eight coil.
12 April 2019 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Current truncating circuit designs used in some controllable pulse width transcranial magnetic stimulation systems can be adapted for use with the peripheral nervous system. Such a scaled-down stimulator produces neuromuscular activation using less stimulus energy than described in previous reports of sciatic nerve stimulation. To evaluate the energy reductions possible with current truncation, we performed six in vivo experiments in rats where the magnetic stimulating coil abutted the sciatic nerve. We used electromyographic data to quantify neuromuscular response, with a criterion level of 20%-of-maximum to indicate a useful level of neuromuscular activation. The energy required to evoke this criterion response from muscles innervated by the sciatic nerve was reduced by approximately 34% from 10.7J with a stimulus waveform lasting 300 ${\mu }\text{s}$ to 7.1J with a waveform lasting 50 ${\mu }\text{s}$ . In water, the 300 ${\mu }\text{s}$ pulse heated the coil by 0.30°C whereas the 50 ${\mu }\text{s}$ pulse heated the coil by 0.15°C. Truncated-waveform magnetic stimulation systems can be used in basic research and clinical applications not requiring rapidly pulsed stimuli. An example of such a clinical application is left vagus nerve stimulation, a treatment that is reported to reduce epileptic partial-onset seizures.
23 June 2020 in Healthcare Technology Letters
Retinal degenerative diseases, such as retinitis pigmentosa, begin with damage to the photoreceptor layer of the retina. In the absence of presynaptic input from photoreceptors, networks of electrically coupled AII amacrine and cone bipolar cells have been observed to exhibit oscillatory behaviour and result in spontaneous firing of ganglion cells. This ganglion cell activity could interfere with external stimuli provided by retinal prosthetic devices and potentially degrade their performance. In this work, the authors computationally investigate stimulus waveform designs, which can improve the performance of retinal prostheses by suppressing undesired spontaneous firing of ganglion cells and generating precise temporal spiking patterns. They utilise a multi‐scale computational model for electrical stimulation of degenerated retina based on the admittance method and NEURON simulation environments. They present a class of asymmetric biphasic pulses that can generate precise ganglion cell firing patterns with up to 55% lower current requirements compared to traditional symmetric biphasic pulses. This lower current results in activation of only proximal ganglion cells, provides more focused stimulation and lowers the risk of tissue damage.
30 March 2021 in Experimental Eye Research