Francis Kalloor Joseph

Dr. Francis Kalloor Joseph

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
RBRianne Bulsink
Rianne Bulsink
Mithun Kuniyil Ajith SinghMithun Kuniyil Ajith Singh
Mithun Kuniyil Ajith Singh
MXMarvin Xavierselvan
Marvin Xavierselvan
Srivalleesha MallidiSrivalleesha Mallidi
Srivalleesha Mallidi
WSWiendelt Steenbergen
Wiendelt Steenbergen
FJFrancis Kalloor Joseph
Francis Kalloor Joseph
Oxygen saturation imaging has potential in several preclinical and clinical applications. Dual-wavelength LED array-based photoacoustic oxygen saturation imaging can be an affordable solution in this case. For the translation of this technology, there is a need to improve its accuracy and validate it against ground truth methods. We propose a fluence compensated oxygen saturation imaging method, utilizing structural information from the ultrasound image, and prior knowledge of the optical properties of the tissue with a Monte-Carlo based light propagation model for the dual-wavelength LED array configuration. We then validate the proposed method with oximeter measurements in tissue-mimicking phantoms. Further, we demonstrate in vivo imaging on small animal and a human subject. We conclude that the proposed oxygen saturation imaging can be used to image tissue at a depth of 6–8 mm in both preclinical and clinical applications.

23 March 2020 in Biomedical Optics Express
Verified
Journal Article
Closed access
FJFrancis Kalloor Joseph
Francis Kalloor Joseph
YBYoeri E. Boink
Yoeri E. Boink
MDMaura Dantuma
Maura Dantuma
Mithun Kuniyil Ajith SinghMithun Kuniyil Ajith Singh
Mithun Kuniyil Ajith Singh
SMSrirang Manohar
Srirang Manohar
WSWiendelt Steenbergen
Wiendelt Steenbergen
Pulsed lasers in photoacoustic tomography systems are expensive, which limit their use to a few clinics and small animal labs. We present a method to realize tomographic ultrasound and photoacoustic imaging using a commercial LED-based photoacoustic and ultrasound system. We present two illumination configurations using LED array units and an optimal number of angular views for tomographic reconstruction. The proposed method can be a cost-effective solution for applications demanding tomographic imaging and can be easily integrated into conventional linear array-based ultrasound systems. We present a potential application for finger joint imaging in vivo, which can be used for point-of-care rheumatoid arthritis diagnosis and monitoring.

1 September 2019 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
FJFrancis Kalloor Joseph
Francis Kalloor Joseph
SMSrirang Manohar
Srirang Manohar
Percutaneous radiofrequency ablation (RFA) is gaining importance as a locoregional treatment for tumors in several organs including the liver, lung, kidney and bone. In RFA, the tumor is eradicated with the direct application of heat using alternating current through a needle electrode positioned under imaging guidance. Various imaging methods are used in the RFA ablation procedure but these have drawbacks. In this work, we introduce photoacoustic (PA) imaging as a new method with potential to visualize the targeting of RFA needle into a region of interest and to report on the extent of ablation achieved. We demonstrate the proof-of-concept in using PA imaging together with ultrasound imaging on ex vivo biological samples in the laboratory simulating relevant clinical scenarios in RFA. These include guidance of the RFA needle to target tissue, mapping of simulated blood vessels during needle insertion and differentiation between ablated and surrounding tissue. The results of this first investigation into the use of PA imaging to assist RFA procedures are encouraging. We discuss the challenges encountered, the scope for future work and envisaged clinical application.

23 September 2017 in Photoacoustics
Verified
Journal Article
Open access
FJFrancis Kalloor Joseph
Francis Kalloor Joseph
BCBhargava Chinni
Bhargava Chinni
SCSumohana S. Channappayya
Sumohana S. Channappayya
RPRajalakshmi Pachamuthu
Rajalakshmi Pachamuthu
VDVikram S. Dogra
Vikram S. Dogra
NRNavalgund Rao
Navalgund Rao
Some of the challenges in translating photoacoustic (PA) imaging to clinical applications includes limited view of the target tissue, low signal to noise ratio and the high cost of developing real-time systems. Acoustic lens based PA imaging systems, also known as PA cameras are a potential alternative to conventional imaging systems in these scenarios. The 3D focusing action of lens enables real-time C-scan imaging with a 2D transducer array. In this paper, we model the underlying physics in a PA camera in the mathematical framework of an imaging system and derive a closed form expression for the point spread function (PSF). Experimental verification follows including the details on how to design and fabricate the lens inexpensively. The system PSF is evaluated over a 3D volume that can be imaged by this PA camera. Its utility is demonstrated by imaging phantom and an ex vivo human prostate tissue sample.

29 June 2021 in Sensors
Verified
Journal Article
Open access
PDF file
HKHindrik Kruit
Hindrik Kruit
FJFrancis Kalloor Joseph
Francis Kalloor Joseph
ERElina Rascevska
Elina Rascevska
SMSrirang Manohar
Srirang Manohar
Unresectable liver tumors are commonly treated with percutaneous radiofrequency ablation (RFA). However, this technique is associated with high recurrence rates due to incomplete tumor ablation. Accurate image guidance of the RFA procedure contributes to successful ablation, but currently used imaging modalities have shortcomings in device guidance and treatment monitoring. We explore the potential of using photoacoustic (PA) imaging combined with conventional ultrasound (US) imaging for real-time RFA guidance. To overcome the low penetration depth of light in tissue, we have developed an annular fiber probe (AFP), which can be inserted into tissue enabling interstitial illumination of tissue. The AFP is a cannula with 72 optical fibers that allows an RFA device to slide through its lumen, thereby enabling PA imaging for RFA device guidance and ablation monitoring. We show that the PA signal from interstitial illumination is not affected by absorber-to-surface depth compared to extracorporeal illumination. We also demonstrate successful imaging of the RFA electrodes, a blood vessel mimic, a tumor-mimicking phantom, and ablated liver tissue boundaries in ex vivo chicken and bovine liver samples. PA-assisted needle guidance revealed clear needle tip visualization, a notable improvement to current US needle guidance. Our probe shows potential for RFA device guidance and ablation detection, which potentially aids in real-time monitoring.

1 March 2019 in Photoacoustics
Verified
Journal Article
Open access
FJFrancis Kalloor Joseph
Francis Kalloor Joseph
BCBhargava Chinni
Bhargava Chinni
SCSumohana S. Channappayya
Sumohana S. Channappayya
RPRajalakshmi Pachamuthu
Rajalakshmi Pachamuthu
VDVikram S. Dogra
Vikram S. Dogra
NRNavalgund Rao
Navalgund Rao
Recently, an acoustic lens has been proposed for volumetric focusing as an alternative to conventional reconstruction algorithms in Photoacoustic (PA) Imaging. Acoustic lens can significantly reduce computational complexity and facilitate the implementation of real-time and cost-effective systems. However, due to the fixed focal length of the lens, the Point Spread Function (PSF) of the imaging system varies spatially. Furthermore, the PSF is asymmetric, with the lateral resolution being lower than the axial resolution. For many medical applications, such as in vivo thyroid, breast and small animal imaging, multiple views of the target tissue at varying angles are possible. This can be exploited to reduce the asymmetry and spatial variation of system the PSF with simple spatial compounding. In this article, we present a formulation and experimental evaluation of this technique. PSF improvement in terms of resolution and Signal to Noise Ratio (SNR) with the proposed spatial compounding is evaluated through simulation. Overall image quality improvement is demonstrated with experiments on phantom and ex vivo tissue. When multiple views are not possible, an alternative residual refocusing algorithm is proposed. The performances of these two methods, both separately and in conjunction, are compared and their practical implications are discussed.