Mithun Kuniyil Ajith Singh

Dr. Mithun Kuniyil Ajith Singh

CYBERDYNE, INC.
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2018 in Sensors
Verified
Journal Article
Open access
PDF file
Wenfeng XiaWenfeng Xia
Wenfeng Xia
Mithun Kuniyil Ajith SinghMithun Kuniyil Ajith Singh
Mithun Kuniyil Ajith Singh
EMEfthymios Maneas
Efthymios Maneas
NSNaoto Sato
Naoto Sato
YSYusuke Shigeta
Yusuke Shigeta
ADAdrien Desjardins
Adrien Desjardins
Ultrasound imaging is widely used to guide minimally invasive procedures, but the visualization of the invasive medical device and the procedure’s target is often challenging. Photoacoustic imaging has shown great promise for guiding minimally invasive procedures, but clinical translation of this technology has often been limited by bulky and expensive excitation sources. In this work, we demonstrate the feasibility of guiding minimally invasive procedures using a dual-mode photoacoustic and ultrasound imaging system with excitation from compact arrays of light-emitting diodes (LEDs) at 850 nm. Three validation experiments were performed. First, clinical metal needles inserted into biological tissue were imaged. Second, the imaging depth of the system was characterized using a blood-vessel-mimicking phantom. Third, the superficial vasculature in human volunteers was imaged. It was found that photoacoustic imaging enabled needle visualization with signal-to-noise ratios that were 1.2 to 2.2 times higher than those obtained with ultrasound imaging, over insertion angles of 26 to 51 degrees. With the blood vessel mimicking phantom, the maximum imaging depth was 38 mm. The superficial vasculature of a human middle finger and a human wrist were clearly visualized in real-time. We conclude that the LED-based system is promising for guiding minimally invasive procedures with peripheral tissue targets.

27 April 2020 in Sensors
Verified
Journal Article
Open access
PDF file
YZYunhao Zhu
Yunhao Zhu
TFTing Feng
Ting Feng
QIAN CHENGQIAN CHENG
QIAN CHENG
Xueding WangXueding Wang
Xueding Wang
SDSidan Du
Sidan Du
Mithun Kuniyil Ajith SinghMithun Kuniyil Ajith Singh
Mithun Kuniyil Ajith Singh
Photoacoustic imaging, with the capability to provide simultaneous structural, functional, and molecular information, is one of the fastest growing biomedical imaging modalities of recent times. As a hybrid modality, it not only provides greater penetration depth than the purely optical imaging techniques, but also provides optical contrast of molecular components in the living tissue. Conventionally, photoacoustic imaging systems utilize bulky and expensive class IV lasers, which is one of the key factors hindering the clinical translation of this promising modality. Use of LEDs which are portable and affordable offers a unique opportunity to accelerate the clinical translation of photoacoustics. In this paper, we first review the development history of LED as an illumination source in biomedical photoacoustic imaging. Key developments in this area, from point-source measurements to development of high-power LED arrays, are briefly discussed. Finally, we thoroughly review multiple phantom, ex-vivo, animal in-vivo, human in-vivo, and clinical pilot studies and demonstrate the unprecedented preclinical and clinical potential of LED-based photoacoustic imaging.

4 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
RBRianne Bulsink
Rianne Bulsink
Mithun Kuniyil Ajith SinghMithun Kuniyil Ajith Singh
Mithun Kuniyil Ajith Singh
MXMarvin Xavierselvan
Marvin Xavierselvan
Srivalleesha MallidiSrivalleesha Mallidi
Srivalleesha Mallidi
WSWiendelt Steenbergen
Wiendelt Steenbergen
FJFrancis Kalloor Joseph
Francis Kalloor Joseph
Oxygen saturation imaging has potential in several preclinical and clinical applications. Dual-wavelength LED array-based photoacoustic oxygen saturation imaging can be an affordable solution in this case. For the translation of this technology, there is a need to improve its accuracy and validate it against ground truth methods. We propose a fluence compensated oxygen saturation imaging method, utilizing structural information from the ultrasound image, and prior knowledge of the optical properties of the tissue with a Monte-Carlo based light propagation model for the dual-wavelength LED array configuration. We then validate the proposed method with oximeter measurements in tissue-mimicking phantoms. Further, we demonstrate in vivo imaging on small animal and a human subject. We conclude that the proposed oxygen saturation imaging can be used to image tissue at a depth of 6–8 mm in both preclinical and clinical applications.

29 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Mithun Kuniyil Ajith SinghMithun Kuniyil Ajith Singh
Mithun Kuniyil Ajith Singh
Wenfeng XiaWenfeng Xia
Wenfeng Xia
Photoacoustic imaging is a hybrid imaging modality that offers the advantages of optical (spectroscopic contrast) and ultrasound imaging (scalable spatial resolution and imaging depth). This promising modality has shown excellent potential in a wide range of preclinical and clinical imaging and sensing applications. Even though photoacoustic imaging technology has matured in research settings, its clinical translation is not happening at the expected pace. One of the main reasons for this is the requirement of bulky and expensive pulsed lasers for excitation. To accelerate the clinical translation of photoacoustic imaging and explore its potential in resource-limited settings, it is of paramount importance to develop portable and affordable light sources that can be used as the excitation light source. In this review, we focus on the following aspects: (1) the basic theory of photoacoustic imaging; (2) inexpensive light sources and different implementations; and (3) important preclinical and clinical applications, demonstrated using affordable light source-based photoacoustics. The main focus will be on laser diodes and light-emitting diodes as they have demonstrated promise in photoacoustic tomography—the key technological developments in these areas will be thoroughly reviewed. We believe that this review will be a useful opus for both the beginners and experts in the field of biomedical photoacoustic imaging.

1 December 2015 in Photoacoustics
Verified
Journal Article
Open access
Mithun Kuniyil Ajith SinghMithun Kuniyil Ajith Singh
Mithun Kuniyil Ajith Singh
WSWiendelt Steenbergen
Wiendelt Steenbergen
Influence of acoustic inhomogeneities and resulting reflection artifacts is an important problem in reflection-mode photoacoustic imaging. Absorption of light by skin and superficial optical absorbers will generate photoacoustic transients, which traverse into the tissue and get reflected from structures having different acoustic impedance. These reflected photoacoustic signals, when reconstructed, may appear in the region of interest, which causes difficulties in image interpretation. We propose a novel method to identify and potentially eliminate reflection artifacts in photoacoustic images using photoacoustic-guided focused ultrasound [PAFUSion]. Our method uses focused ultrasound pulses to mimic the wave field produced by photoacoustic sources and thus provides a way to identify reflection artifacts in clinical combined photoacoustic and pulse-echo ultrasound. Simulation and phantom results are presented to demonstrate the validity and impact of this method. Results show that PAFUSion can identify reflections in photoacoustic images and thus envisages potential for improving photoacoustic imaging of acoustically inhomogeneous tissue.

23 March 2020 in Biomedical Optics Express
Verified
Journal Article
Closed access
FJFrancis Kalloor Joseph
Francis Kalloor Joseph
YBYoeri E. Boink
Yoeri E. Boink
MDMaura Dantuma
Maura Dantuma
Mithun Kuniyil Ajith SinghMithun Kuniyil Ajith Singh
Mithun Kuniyil Ajith Singh
SMSrirang Manohar
Srirang Manohar
WSWiendelt Steenbergen
Wiendelt Steenbergen
Pulsed lasers in photoacoustic tomography systems are expensive, which limit their use to a few clinics and small animal labs. We present a method to realize tomographic ultrasound and photoacoustic imaging using a commercial LED-based photoacoustic and ultrasound system. We present two illumination configurations using LED array units and an optimal number of angular views for tomographic reconstruction. The proposed method can be a cost-effective solution for applications demanding tomographic imaging and can be easily integrated into conventional linear array-based ultrasound systems. We present a potential application for finger joint imaging in vivo, which can be used for point-of-care rheumatoid arthritis diagnosis and monitoring.