Andrea Pérez-Velasco

Ms. Andrea Pérez-Velasco


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2019 in Journal of Dentistry
Verified
Journal Article
Closed access
FAFrancisco Azcarate-Velázquez
Francisco Azcarate-Velázquez
RCRaquel Castillo-Oyagüe
Raquel Castillo-Oyagüe
LOLuis-Guillermo Oliveros-López
Luis-Guillermo Oliveros-López
Daniel Torres-LagaresDaniel Torres-Lagares
Daniel Torres-Lagares
ÁGÁlvaro José Martínez González
Álvaro José Martínez González
María-Angeles Serrera-FigalloMaría-Angeles Serrera-Figallo
María-Angeles Serrera-Figallo

18 May 2020 in Metals
Verified
Journal Article
Open access
PDF file
CHCristina Herráez
Cristina Herráez
Daniel Torres-LagaresDaniel Torres-Lagares
Daniel Torres-Lagares
ÁGÁlvaro José Martínez González
Álvaro José Martínez González
APAndrea Pérez-Velasco
Andrea Pérez-Velasco
ETEusebio Torres-Carranza
Eusebio Torres-Carranza
JGJose-Luis Gutiérrez-Perez
Jose-Luis Gutiérrez-Perez
This study is a contribution to our understanding of the mechanical behaviour of dental implants through the use of the finite element and the photoelastic methods. Two internal connection and bone level dental implants with different design have been analysed (M-12 by Oxtein S.L., Zaragoza, Spain, and ASTRA, from Dentsply Sirona, Charlotte, NC, USA), evaluating the stress distribution produced by axial stresses and a comparison has been established between them, as well as between the two methods used, in order to validate the adopted hypotheses and correlate the numerical modelling performed with experimental tests. To load the implant in laboratory testing, a column was placed, such that the loading point was about 9.3 mm from the upper free surface of the resin plate. This column connects the implant with the weights used to define the test load. In turn, support for both plates was achieved by two 6 mm bolts 130 mm apart and located on a parallel line with the resin (flush with the maximum level of the implant), at a depth of 90 mm. The results obtained with both methods used were similar enough. The comparison of results is fundamentally visual, but ensures that, at least in the range of forces used, both methods are similar. Therefore, the photoelastic method can be used to confirm in a real way the virtual conditions of the finite element models, with the implications in the investigation of dental implants that this entails.

22 August 2020 in Metals
Verified
Journal Article
Open access
PDF file
LOLuis-Guillermo Oliveros-López
Luis-Guillermo Oliveros-López
RCRaquel Castillo-De-Oyagüe
Raquel Castillo-De-Oyagüe
María-Angeles Serrera-FigalloMaría-Angeles Serrera-Figallo
María-Angeles Serrera-Figallo
ÁGÁlvaro José Martínez González
Álvaro José Martínez González
APAndrea Pérez-Velasco
Andrea Pérez-Velasco
JGJose-Luis Gutiérrez-Perez
Jose-Luis Gutiérrez-Perez
Bruxism is an unconscious, involuntary and sustained motor activity that results in excessive teeth grinding or jaw clenching that could affect patients’ implants and rehabilitations. The aetiology for bruxism remains unknown, but it is known to involve multiple factors. The literature lacks studies on the possible effect of implant morphology on the resistance of the bone-implant osseointegrated interface when bruxism is present. Our objective is to assess the mechanical response of the bone-implant interface in bruxist patients whose implant prostheses are subjected to parafunctional cyclic loading over a simulated period of 10 years. A comparison was carried out between two implant types (M-12 and Astra Tech), and a pattern of bone loss was established considering both the stress state and the cortical bone surface loss as the evaluation criteria. Numerical simulation techniques based on the finite element analysis method were applied in a dynamic analysis of the received forces, together with a constitutive model of bone remodelling that alters the physical properties of the bone. The simulated cortical bone surface loss at the implant neck area was 8.6% greater in the Astra implant than in the M-12 implant. Compared to the M-12 implant, the higher sustained stress observed over time in the Astra implant, together with the greater cortical bone surface loss that occurred at its neck area, may be related to the major probability of failure of the prostheses placed over Astra implants in bruxist patients.