Conventionally, plastic anisotropy is calibrated by using standard uniaxial tensile and biaxial test results. Alternatively, heterogeneous strain field specimens in combination with full-field measurements can be used for this purpose. As reported by the literature, such an approach reduces the number of required tests enormously, but it is challenging to obtain reliable results. This paper presents an alternative methodology, which represents a compromise between the conventional and heterogeneous strain field calibration technique. The idea of the method is to use simple tests, which can be conducted on the uniaxial testing machine, and to avoid the use of advanced measuring equipment. The procedure is accomplished by conducting standard tensile tests, which are simple and reliable, and by a novel heterogeneous strain field tensile test, to calibrate the biaxial stress state. Moreover, only two of the parameters required for full characterisation need to be inversely identified from the test response; the other parameters are directly determined from the uniaxial tensile test results. This way, a dimension of optimization space is reduced substantially, which increases the robustness and effectiveness of the optimization algorithm.
1 August 2016 in Sensors and Actuators A: Physical
In designing high-performance, lightweight components, cellular structures are one of the approaches to be considered. The present study aimed to analyze the effect of the infill line distance of 3D printed circular samples on their compressive elastic behavior. Lightweight cellular poly-lactic acid (PLA) samples with a triangular infill pattern were exposed to cyclic compressive loading and their stiffness was investigated. PLA is one of the most commonly used thermoplastic materials in additive manufacturing using the fused filament fabrication (FFF) process. Cylindrical samples with a diameter of 11.42 mm and a height of 10 mm were printed using FFF technology with two different infill line distances (1.6 mm and 2.4 mm). Comparing the nominal compressive stress-nominal strain curves under cyclic loading showed that the first cycle response was significantly different with respect to the subsequent ones. Furthermore, an analysis of the dependence of the modulus of elasticity on the effects of cyclic loading was performed. It was found that through elastic deformation, and combined elastic and plastic deformation, the samples’ properties such as stiffness could be altered.
Quadruple glazing has become a high-end standard in the field of sealed insulating glass units. With more than three glass panes a set of internal heat-related technical problems emerges. Durability, being the most pressing problem, requires careful management of the primary sealant deformation, especially under summer environmental conditions. Namely, the role of the primary seal in insulating glass units is to protect their humidity-sensitive, low-emissivity coatings from moisture and the quality of such protection is a key factor in durability. In this paper, a new methodology is proposed for a feasibility assessment of a new multipane insulating glass unit design, where proper design enables avoidance of excessive strain on the primary seal. It focuses on the calculation of the primary sealant strains, which are nonhomogeneous and multiaxial according to different loading conditions. This approach leads to analytical expressions that enable convenient identification of the critical location on the primary sealant. Finally, feasibility is assessed with the proposed methodology for the newly developed highly insulative six-pane facade unit by means of a comparison of the calculated strain state with the anticipated allowable strains, based on technical practice.
23 February 2025 in International Journal of Solids and Structures
The accuracy of numerical predictions in sheet metal processes involving multiaxial stress–strain states (e.g., blanking, riveting, and incremental forming) heavily depends on the characterisation of plastic anisotropy under multiaxial loading conditions. A fully calibrated 3D plastic anisotropy model is essential for this purpose. While in-plane material behaviour can be conventionally characterised through uniaxial and equi-biaxial tensile tests, calibrating out-of-plane material behaviour remains a significant challenge. This behaviour, governed by out-of-plane shear stress and associated material parameters, is typically described by out-of-plane shear yielding. These parameters are notoriously difficult to determine, leading researchers to frequently assume isotropic behaviour or identical shear parameters for in-plane and out-of-plane responses. Although advanced calibrations may utilise crystal plasticity modelling, there remains a critical need for macro-mechanical characterisation methods. This paper presents an out-of-plane shear testing and material characterisation procedure based on full-field strain measurements using digital image correlation (DIC). Strains within the shear zone are measured via DIC and employed in the Finite Element Model Updating (FEMU) to identify out-of-plane shear parameters of a 2.42 mm thick, cold-rolled AW5754-H22 aluminium alloy sheet, using the Yld2004-18p yield criterion. Given that the characteristic strain response at this scale may be influenced by local crystal structure behaviour on the surface, this paper evaluates the feasibility of such measurements. Finally, to test the validity of the full-field-based approach, the FEMU-identified parameters are compared against results obtained through a classical optimisation procedure based on force-elongation measurements from the shear zone.