Niels Hammer

Dr. Niels Hammer

Institute of Macroscopic and Clinical Anatomy, Medical University of Graz, Austria
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 March 2012 in Anatomical Sciences Education
Verified
Journal Article
Closed access
PDF file
NHNiels Hammer
Niels Hammer
SLSabine Löffler
Sabine Löffler
CFChristine Feja
Christine Feja
MSMara Sandrock
Mara Sandrock
WSWolfgang Schmidt
Wolfgang Schmidt
HSHanno Steinke
Hanno Steinke

4 April 2014 in Anatomical Sciences Education
Verified
Journal Article
Closed access
PDF file
NHNiels Hammer
Niels Hammer
SLSabine Löffler
Sabine Löffler
IBIngo Bechmann
Ingo Bechmann
HSHanno Steinke
Hanno Steinke
CHCarsten Hädrich
Carsten Hädrich
CFChristine Feja
Christine Feja

13 November 2019 in Scientific Reports
Verified
Journal Article
Open access
JZJohann Zwirner
Johann Zwirner
MSMario Scholze
Mario Scholze
JWJohn Neil Waddell
John Neil Waddell
BOBenjamin Ondruschka
Benjamin Ondruschka
NHNiels Hammer
Niels Hammer
Realistic human head models are of great interest in traumatic brain injury research and in the forensic pathology courtroom and teaching. Due to a lack of biomechanical data, the human dura mater is underrepresented in head models. This study provides tensile data of 73 fresh human cranial dura mater samples retrieved from an area between the anterior middle and the posterior middle meningeal artery. Tissues were adapted to their native water content using the osmotic stress technique. Tensile tests were conducted under quasi-static uniaxial testing conditions with simultaneous digital image correlation. Human temporal dura mater is mechanically highly variable with regards to its elastic modulus of 70 ± 44 MPa, tensile strength of 7 ± 4 MPa, and maximum strain of 11 ± 3 percent. Mechanical properties of the dura mater did not vary significantly between side nor sex and decreased with the age of the cadaver. Both elastic modulus and tensile strength appear to have constant mechanical parameters within the first 139 hours post mortem. The mechanical properties provided by this study can help to improve computational and physical human head models. These properties under quasi-static conditions do not require adjustments for side nor sex, whereas adjustments of tensile properties accompanied with normal aging may be of interest.

2 July 2020 in Clinical and Experimental Dental Research
Verified
Journal Article
Open access
PDF file
JCJoanne Choi
Joanne Choi
JZJohann Zwirner
Johann Zwirner
RRRishi Sanjay Ramani
Rishi Sanjay Ramani
SMSunyoung Ma
Sunyoung Ma
HHHaizal Mohd Hussaini
Haizal Mohd Hussaini
NHNiels Hammer
Niels Hammer
Aim: To investigate load‐deformation properties of Thiel‐embalmed human oral mucosa tissues and to compare three different anatomical regions in terms of mechanical, histological and ultrastructural characteristic with focus on the extracellular matrix.Materials and Methods: Thirty specimens from three different regions of the oral cavity: attached gingiva, buccal mucosa and the hard palate were harvested from two Thiel‐embalmed cadavers. Mechanical properties were obtained, combining strain evaluation and digital image correlation in a standardised approach. Elastic modulus, tensile strength, strain at maximum load and strain to failure were computed and analysed statistically. Subsamples were also analysed using scanning electron microscopy (SEM) and histological analysis.Results: The highest elastic modulus of 37.36 ± 17.4 MPa was found in the attached gingiva group, followed by the hard palate and buccal mucosa. The elastic moduli of attached gingiva differed significantly to the buccal mucosa (p = .01) and hard palate (p = .021). However, there was no difference in the elastic moduli between the buccal mucosa and hard palate (p > .22). The tensile strength of the tissue samples ranged from 1.54 ± 0.5MPa to 3.81 ± 0.9 MPa, with a significant difference between gingiva group and buccal mucosa or hard palate (p = .001). No difference was found in the mean tensile strength between the buccal mucosa and hard palate (p = .92). Ultrastructural imaging yielded a morphological basis for the various mechanical properties found intraorally; the attached gingiva showed unidirectional collagen fibre network whereas the buccal mucosa and hard palate showed multi‐directional network, which was more prone to tension failure and less elasticity.Conclusion: This is the first study assessing the various morphological‐mechanical relationships of intraoral soft tissues, utilising Thiel‐embalmed tissues. The findings of this study suggest that the tissues from different intraoral regions showed various morphological‐mechanical behaviour which was also confirmed under the SEM and in the histological analysis.

1 November 2012 in Medical Engineering & Physics
Verified
Journal Article
Closed access
HSHanno Steinke
Hanno Steinke
ULUwe Lingslebe
Uwe Lingslebe
JBJörg Böhme
Jörg Böhme
VSVolker Slowik
Volker Slowik
VSVickie Shim
Vickie Shim
NHNiels Hammer
Niels Hammer
The iliotibial tract (tract) is an important structure for the biomechanics of both the hip and knee joint. While a detailed characterization of its mechanical properties might help to better understand its specific role in the load transfer from the pelvis to femur and tibia, determination of those properties is complicated by its particular structure of thin fibers in the fresh state. Moreover, although the tracts mechanical properties are often derived from cadaveric material chemically fixed with either ethanol or formaldehyde, the influence of such fixation methods remains to be elucidated. Aim of this study was to determine Young's modulus (tensile modulus, YM) of the tract. We hypothesized that either ethanol or formaldehyde fixation would significantly increase the YM compared to the tracts condition in a fresh state. 13 specimens of tract were gained from donators. The ends of the probes were plastinated with resin creating a sharp interface between the clamp and the probe to prevent material slippage. The specimens were measured in their fresh state, under ethanol- and formaldehyde-fixed conditions and re-measured after rinsing with tap water. The YM of the fresh probes averaged 397.3N/mm(2) with a standard deviation (SD) of 151.5N/mm(2). The YM of the ethanol-fixed specimens was significantly higher (673.2N/mm(2), SD 328.5N/mm(2), p<0.05). After rinsing with tap water, the YM decreased to 95% of the fresh condition value (377.4N/mm(2), SD 144.5N/mm(2), non-significant change from fresh). After formaldehyde fixation, the YM reached 490.3N/mm(2) (SD 143.0N/mm(2), p<0.05). When the formaldehyde-fixed specimens were rinsed, the YM was 114% of the value of the fresh condition (452.6N/mm(2), SD 115.1N/mm(2), non-significant change from fresh). This study found a significant influence of the chemical fixation method on the YM of the IT tract. If such fixation is required, our results suggest using a treatment with ethanol and subsequent rinsing that results in minimal changes to the tracts YM. Furthermore, plastination of the ends of the specimens could be crucial to allow in vitro determination of valid YM of ligaments data that can then be integrated with confidence in further finite element analyses.

22 May 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
NHNiels Hammer
Niels Hammer
SLSabine Löffler
Sabine Löffler
YCYusuf Ozgur Cakmak
Yusuf Ozgur Cakmak
BOBenjamin Ondruschka
Benjamin Ondruschka
UPUwe Planitzer
Uwe Planitzer
DWDavid Weise
David Weise
Vagus nerve stimulation (VNS) has become a well-established therapy for epilepsy and depression, and is emerging to treat inflammatory disease, with the cervical vagus nerve (CVN) as major stimulation site. CVN morphometries are missing for VNS, considering its variability. Morphometric data were obtained from CVNs in 27 cadavers, including branching patterns and histology. Cross-sectional area, greater and lesser diameters averaged 7.2 ± 3.1 mm2, 5.1 ± 1.5 and 4.1 ± 1.3 mm, and were ≤11.0 mm2, ≤7.0 and ≤5.8 mm in 90% of the specimens, respectively. Midline distance (position lateral to the laryngeal eminence) and skin distance (anterior-posterior from skin) averaged 34.5 ± 6.2 and 36.2 ± 9.4 mm, ≤49.0 and ≤41.0 mm in 90%, respectively. Nerve dimensions and surface topography correlated closely, but without gender-, side- or branching-dependent differences. The nerve fascicle number averaged 5.2 ± 3.5. Vagal arteries were observed in 49% of the cases. Negative correlations were found for age and cross-sectional area, as well as subperineural vessel count. Detailed anatomical data on the CVN and its vascularity are given, forming the morphometric basis for VNS refinement, filling an evident gap in light of the CVN being a structure with variable positions and branching. A 35 × 35-mm rule may apply for the CVN position, irrespective of branching or positional variation.