Montserrat Rivas

Dr. Montserrat Rivas

University of Oviedo, Spain
orcid

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 January 2019 in Bioengineering
Verified
Journal Article
Open access
PDF file
ESEsther Serrano-Pertierra
Esther Serrano-Pertierra
MOMyriam Oliveira-Rodríguez
Myriam Oliveira-Rodríguez
MRMontserrat Rivas
Montserrat Rivas
POPedro Oliva
Pedro Oliva
JVJavier Villafani
Javier Villafani
ECEva Cernuda-Morollón
Eva Cernuda-Morollón
Extracellular vesicles (EV) are small membrane structures released by cells that act as potent mediators of intercellular communication. The study of EV biology is important, not only to strengthen our knowledge of their physiological roles, but also to better understand their involvement in several diseases. In the field of biomedicine they have been studied as a novel source of biomarkers and drug delivery vehicles. The most commonly used method for EV enrichment in crude pellet involves serial centrifugation and ultracentrifugation. Recently, different protocols and techniques have been developed to isolate EV that imply less time and greater purification. Here we carry out a comparative analysis of three methods to enrich EV from plasma of healthy controls: ultracentrifugation, ExoQuickTM precipitation solution (System Biosciences), and Total Exosome Isolation kit (Invitrogen). Our results show that commercial precipitation reagents are more efficient and enable higher EV enrichment factors compared with traditional ultracentrifugation, although subsequent imaging analysis is not possible with some of them. We hope that this work will contribute to the current research on isolation techniques to assist the progress of clinical applications with diagnostic or therapeutic objectives.

28 May 2020 in Biomolecules
Verified
Journal Article
Open access
PDF file
ESEsther Serrano-Pertierra
Esther Serrano-Pertierra
MOMyriam Oliveira-Rodríguez
Myriam Oliveira-Rodríguez
Maria MatosMaria Matos
Maria Matos
GGGemma Gutiérrez
Gemma Gutiérrez
AMAmanda Moyano
Amanda Moyano
Maria Carmen Blanco-LopezMaria Carmen Blanco-Lopez
Maria Carmen Blanco-Lopez
Since their first observation, understanding the biology of extracellular vesicles (EV) has been an important and challenging field of study. They play a key role in the intercellular communication and are involved in important physiological and pathological functions. Therefore, EV are considered as potential biomarkers for diagnosis, prognosis, and monitoring the response to treatment in some diseases. In addition, due to their properties, EV may be used for therapeutic purposes. In the study of EV, three major points have to be addressed: 1. How to isolate EV from cell culture supernatant/biological fluids, 2. how to detect them, and 3. how to characterize and quantify. In this review, we focus on the last two questions and provide the main analytical techniques up-to-date for detection and profiling of EV. We critically analyze the advantages and disadvantages of each one, aimed to be of relevance for all researchers working on EV biology and their potential applications.

8 May 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
AMAmanda Moyano
Amanda Moyano
ESEsther Serrano-Pertierra
Esther Serrano-Pertierra
María SalvadorMaría Salvador
María Salvador
JMJosé Carlos Martínez-García
José Carlos Martínez-García
MRMontserrat Rivas
Montserrat Rivas
Maria Carmen Blanco-LopezMaria Carmen Blanco-Lopez
Maria Carmen Blanco-Lopez
A new generation of magnetic lateral flow immunoassays is emerging as powerful tool for diagnostics. They rely on the use of magnetic nanoparticles (MNP) as detecting label, replacing conventional gold or latex beads. MNPs can be sensed and quantified by means of external devices, allowing the development of immunochromatographic tests with a quantitative capability. Moreover, they have an added advantage because they can be used for immunomagnetic separation (IMS), with improvements in selectivity and sensitivity. In this paper, we have reviewed the current knowledge on magnetic-lateral flow immunoassay (LFIA), coupled with both research and commercially available instruments. The work in the literature has been classified in two categories: optical and magnetic sensing. We have analysed the type of magnetic nanoparticles used in each case, their size, coating, crystal structure and the functional groups for their conjugation with biomolecules. We have also taken into account the analytical characteristics and the type of transduction. Magnetic LFIA have been used for the determination of biomarkers, pathogens, toxins, allergens and drugs. Nanocomposites have been developed as alternative to MNP with the purpose of sensitivity enhancement. Moreover, IMS in combination with other detection principles could also improve sensitivity and limit of detection. The critical analysis in this review could have an impact for the future development of magnetic LFIA in fields requiring both rapid separation and quantification.

30 June 2020 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Alexander OmelyanchikAlexander Omelyanchik
Alexander Omelyanchik
María SalvadorMaría Salvador
María Salvador
FDFranco D'Orazio
Franco D'Orazio
Valentina MameliValentina Mameli
Valentina Mameli
Carla CannasCarla Cannas
Carla Cannas
Davide PeddisDavide Peddis
Davide Peddis
The effect of the annealing temperature Tann on the magnetic properties of cobalt ferrite nanoparticles embedded in an amorphous silica matrix (CoFe2O4/SiO2), synthesized by a sol-gel auto-combustion method, was investigated by magnetization and AC susceptibility measurements. For samples with 15% w/w nanoparticle concentration, the particle size increases from ~2.5 to ~7 nm, increasing Tann from 700 to 900 °C. The effective magnetic anisotropy constant (Keff) increases with decreasing Tann, due to the increase in the surface contribution. For a 5% w/w sample annealed at 900 °C, Keff is much larger (1.7 × 106 J/m3) than that of the 15% w/w sample (7.5 × 105 J/m3) annealed at 700 °C and showing comparable particle size. This indicates that the effect of the annealing temperature on the anisotropy is not only the control of the particle size but also on the core structure (i.e., cation distribution between the two spinel sublattices and degree of spin canting), strongly affecting the magnetocrystalline anisotropy. The results provide evidence that the magnetic anisotropy comes from a complex balance between core and surface contributions that can be controlled by thermal treatments.

30 July 2019 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
AMAmanda Moyano
Amanda Moyano
MSMaría Salvador
María Salvador
JMJosé C. Martínez-García
José C. Martínez-García
VSVlad Socoliuc
Vlad Socoliuc
LVLadislau Vékás
Ladislau Vékás
Maria Carmen Blanco-LopezMaria Carmen Blanco-Lopez
Maria Carmen Blanco-Lopez

22 July 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
AMAmanda Moyano
Amanda Moyano
ESEsther Serrano-Pertierra
Esther Serrano-Pertierra
María SalvadorMaría Salvador
María Salvador
JMJosé Carlos Martínez-García
José Carlos Martínez-García
YPYolanda Piñeiro
Yolanda Piñeiro
Maria Carmen Blanco-LopezMaria Carmen Blanco-Lopez
Maria Carmen Blanco-Lopez
Superparamagnetic iron oxide nanoflowers coated by a black carbon layer (Fe3O4@C) were studied as labels in lateral flow immunoassays. They were synthesized by a one-pot solvothermal route, and they were characterized (size, morphology, chemical composition, and magnetic properties). They consist of several superparamagnetic cores embedded in a carbon coating holding carboxylic groups adequate for bioconjugation. Their multi-core structure is especially efficient for magnetic separation while keeping suitable magnetic properties and appropriate size for immunoassay reporters. Their functionality was tested with a model system based on the biotin–neutravidin interaction. For this, the nanoparticles were conjugated to neutravidin using the carbodiimide chemistry, and the lateral flow immunoassay was carried out with a biotin test line. Quantification was achieved with both an inductive magnetic sensor and a reflectance reader. In order to further investigate the quantifying capacity of the Fe3O4@C nanoflowers, the magnetic lateral flow immunoassay was tested as a detection system for extracellular vesicles (EVs), a novel source of biomarkers with interest for liquid biopsy. A clear correlation between the extracellular vesicle concentration and the signal proved the potential of the nanoflowers as quantifying labels. The limit of detection in a rapid test for EVs was lower than the values reported before for other magnetic nanoparticle labels in the working range 0–3 × 107 EVs/μL. The method showed a reproducibility (RSD) of 3% (n = 3). The lateral flow immunoassay (LFIA) rapid test developed in this work yielded to satisfactory results for EVs quantification by using a precipitation kit and also directly in plasma samples. Besides, these Fe3O4@C nanoparticles are easy to concentrate by means of a magnet, and this feature makes them promising candidates to further reduce the limit of detection.