Mohd Danish

Dr. Mohd Danish

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2017 in The International Journal of Advanced Manufacturing Technology
Verified
Journal Article
Closed access
PDF file
MDMohd Danish
Mohd Danish
TGTURNAD GINTA
TURNAD GINTA
KHKhairul Habib
Khairul Habib
DIEGO CAROUDIEGO CAROU
DIEGO CAROU
ARAhmad Majdi Abdul Rani
Ahmad Majdi Abdul Rani
BSBidyut Baran Saha
Bidyut Baran Saha

28 March 2024 in Results in Engineering
Verified
Journal Article
Open access
MDMohd Danish
Mohd Danish
MGMunish Kumar Gupta
Munish Kumar Gupta
SISayed Ameenuddin Irfan
Sayed Ameenuddin Irfan
SGSami Mansour Ghazali
Sami Mansour Ghazali
MRMuhammad Faisal Rathore
Muhammad Faisal Rathore
AAAhmad Alsaady
Ahmad Alsaady

6 July 2020 in Materials
Verified
Journal Article
Open access
PDF file
Kubilay AslantasKubilay Aslantas
Kubilay Aslantas
MDMohd Danish
Mohd Danish
AHAhmet Hasçelik
Ahmet Hasçelik
Mozammel MiaMozammel Mia
Mozammel Mia
MGMunish Gupta
Munish Gupta
HIHassan Ijaz
Hassan Ijaz
Micro-turning is a micro-mechanical cutting method used to produce small diameter cylindrical parts. Since the diameter of the part is usually small, it may be a little difficult to improve the surface quality by a second operation, such as grinding. Therefore, it is important to obtain the good surface finish in micro turning process using the ideal cutting parameters. Here, the multi-objective optimization of micro-turning process parameters such as cutting speed, feed rate and depth of cut were performed by response surface method (RSM). Two important machining indices, such as surface roughness and material removal rate, were simultaneously optimized in the micro-turning of a Ti6Al4V alloy. Further, the scanning electron microscope (SEM) analysis was done on the cutting tools. The overall results depict that the feed rate is the prominent factor that significantly affects the responses in micro-turning operation. Moreover, the SEM results confirmed that abrasion and crater wear mechanism were observed during the micro-turning of a Ti6Al4V alloy.

28 June 2021 in Materials
Verified
Journal Article
Open access
PDF file
MAMd Al-Amin
Md Al-Amin
ARAhmad Majdi Abdul Rani
Ahmad Majdi Abdul Rani
MDMohd Danish
Mohd Danish
SRSaeed Rubaiee
Saeed Rubaiee
AAbdullah Bin Mahfouz
Abdullah Bin Mahfouz
MSMohd Hafis Sulaiman
Mohd Hafis Sulaiman
Together, 316L steel, magnesium-alloy, Ni-Ti, titanium-alloy, and cobalt-alloy are commonly employed biomaterials for biomedical applications due to their excellent mechanical characteristics and resistance to corrosion, even though at times they can be incompatible with the body. This is attributed to their poor biofunction, whereby they tend to release contaminants from their attenuated surfaces. Coating of the surface is therefore required to mitigate the release of contaminants. The coating of biomaterials can be achieved through either physical or chemical deposition techniques. However, a newly developed manufacturing process, known as powder mixed-electro discharge machining (PM-EDM), is enabling these biomaterials to be concurrently machined and coated. Thermoelectrical processes allow the migration and removal of the materials from the machined surface caused by melting and chemical reactions during the machining. Hydroxyapatite powder (HAp), yielding Ca, P, and O, is widely used to form biocompatible coatings. The HAp added-EDM process has been reported to significantly improve the coating properties, corrosion, and wear resistance, and biofunctions of biomaterials. This article extensively explores the current development of bio-coatings and the wear and corrosion characteristics of biomaterials through the HAp mixed-EDM process, including the importance of these for biomaterial performance. This review presents a comparative analysis of machined surface properties using the existing deposition methods and the EDM technique employing HAp. The dominance of the process factors over the performance is discussed thoroughly. This study also discusses challenges and areas for future research.

23 August 2019 in Journal of Thermal Analysis and Calorimetry
Verified
Journal Article
Closed access
PDF file
MDMohd Danish
Mohd Danish
SYSyed Mohd Yahya
Syed Mohd Yahya
BSBidyut Baran Saha
Bidyut Baran Saha

30 March 2018 in Heat Transfer Engineering
Verified
Journal Article
Closed access
MDMohd Danish
Mohd Danish
TGTurnad Lenggo Ginta
Turnad Lenggo Ginta
KHKhairul Habib
Khairul Habib
ARAhmad Majdi Abdul Rani
Ahmad Majdi Abdul Rani
BSBidyut Baran Saha
Bidyut Baran Saha
A combined analytical and experimental study was carried out to analyze the effects of cryogenic cooling on temperature during turning of AZ31C magnesium alloy. Finite element method was employed to model and simulating the cryogenic and dry turning. Results obtained from the model were found to be in good agreement with the experimental observations. For the maximum temperature at the turned surface, the difference in the experimental and predicted value observed during dry and cryogenic turning was only 4 and 8% respectively. A significant reduction in the maximum temperature on the chip surface (around 35%) and tool surface (around 29%) was observed during the cryogenic turning compared to dry turning. This reduction in temperature was an attribute of liquid nitrogen, which produces intense cooling effect around the vicinity cutting zone where heat generation takes place hence enhancing the heat transfer. The isothermal region belonging to the highest temperature on the tool surface was also reduced by about 42%. The reduction in temperature during cryogenic conditions were found to be beneficial for the machining of magnesium alloys under safe conditions, reducing the risk of ignition and explosions, and also increases the sustainability of the process.