Roman Romashko

Prof. Roman Romashko

Institute of Automation and Control Processes, Primorskiy, Russia
orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 May 2015 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Alexei KamshilinAlexei Kamshilin
Alexei Kamshilin
ENErvin Nippolainen
Ervin Nippolainen
ISIgor S. Sidorov
Igor S. Sidorov
PVPetr V. Vasilev
Petr V. Vasilev
NENikolai P. Erofeev
Nikolai P. Erofeev
Roman RomashkoRoman Romashko
Roman Romashko
Photoplethysmography (PPG) is a noninvasive optical method accepted in the clinical use for measurements of arterial oxygen saturation. It is widely believed that the light intensity after interaction with the biological tissue in vivo is modulated at the heartbeat frequency mainly due to pulsatile variations of the light absorption caused by arterial blood-volume pulsations. Here we report experimental observations, which are not consistent with this model and demonstrate the importance of elastic deformations of the capillary bed in the formation of the PPG waveform. These results provide new insight on light interaction with live tissue. To explain the observations we propose a new model of PPG in which pulse oscillations of the arterial transmural pressure deform the connective-tissue components of the dermis resulting in periodical changes of both the light scattering and absorption. These local changes of the light-interaction parameters are detected as variations of the light intensity returned to a photosensitive camera. Therefore, arterial pulsations can be indirectly monitored even by using the light, which slightly penetrates into the biological tissue.

12 February 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
BABoris Andryukov
Boris Andryukov
NBNatalya N. Besednova
Natalya N. Besednova
Roman RomashkoRoman Romashko
Roman Romashko
TZTatyana S. Zaporozhets
Tatyana S. Zaporozhets
TETimofey Efimov
Timofey Efimov
Infections pose a serious global public health problem and are a major cause of premature mortality worldwide. One of the most challenging objectives faced by modern medicine is timely and accurate laboratory-based diagnostics of infectious diseases. Being a key factor of timely initiation and success of treatment, it may potentially provide reduction in incidence of a disease, as well as prevent outbreak and spread of dangerous epidemics. The traditional methods of laboratory-based diagnostics of infectious diseases are quite time- and labor-consuming, require expensive equipment and qualified personnel, which restricts their use in case of limited resources. Over the past six decades, diagnostic technologies based on lateral flow immunoassay (LFIA) have been and remain true alternatives to modern laboratory analyzers and have been successfully used to quickly detect molecular ligands in biosubstrates to diagnose many infectious diseases and septic conditions. These devices are considered as simplified formats of modern biosensors. Recent advances in the development of label-free biosensor technologies have made them promising diagnostic tools that combine rapid pathogen indication, simplicity, user-friendliness, operational efficiency, accuracy, and cost effectiveness, with a trend towards creation of portable platforms. These qualities exceed the generally accepted standards of microbiological and immunological diagnostics and open up a broad range of applications of these analytical systems in clinical practice immediately at the site of medical care (point-of-care concept, POC). A great variety of modern nanoarchitectonics of biosensors are based on the use of a broad range of analytical and constructive strategies and identification of various regulatory and functional molecular markers associated with infectious bacterial pathogens. Resolution of the existing biosensing issues will provide rapid development of diagnostic biotechnologies.

1 February 2009 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
Alexei KamshilinAlexei Kamshilin
Alexei Kamshilin
Roman RomashkoRoman Romashko
Roman Romashko
YKYuri N. Kulchin
Yuri N. Kulchin
This work presents a review of progress and development in the field of adaptive laser interferometry. This method enables highly precise and reliable measurement of various physical parameters under unstable environmental conditions, which makes it very attractive for numerous industrial applications.

1 June 2016 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
OKOleg Kamenev
Oleg Kamenev
YKYuri N. Kulchin
Yuri N. Kulchin
YPYuri S. Petrov
Yuri S. Petrov
RKRuslan V. Khiznyak
Ruslan V. Khiznyak
Roman RomashkoRoman Romashko
Roman Romashko

21 October 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ISIgor S. Sidorov
Igor S. Sidorov
Roman RomashkoRoman Romashko
Roman Romashko
VKVasily T. Koval
Vasily T. Koval
RGRashid Giniatullin
Rashid Giniatullin
Alexei KamshilinAlexei Kamshilin
Alexei Kamshilin
We recently pointed out the important role of dermis deformation by pulsating arterial pressure in the formation of a photoplethysmographic signal at green light. The aim of this study was to explore the role of this novel finding in near-infrared (NIR) light. A light-emitting diode (LED)-based imaging photoplethysmography (IPPG) system was used to detect spatial distribution of blood pulsations under frame-to-frame switching green and NIR illumination in the palms of 34 healthy individuals. We observed a significant increase of light-intensity modulation at the heartbeat frequency for both illuminating wavelengths after a palm was contacted with a glass plate. Strong positive correlation between data measured at green and NIR light was found, suggesting that the same signal was read independently from the depth of penetration. Analysis of the data shows that an essential part of remitted NIR light is modulated in time as a result of elastic deformations of dermis caused by variable blood pressure in the arteries. Our observations suggest that in contrast with the classical model, photoplethysmographic waveform originates from the modulation of the density of capillaries caused by the variable pressure applied to the skin from large blood vessels. Particularly, beat-to-beat transmural pressure in arteries compresses/decompresses the dermis and deforms its connective-tissue components, thus affecting the distance between the capillaries, which results in the modulation of absorption and scattering coefficients of both green and NIR light. These findings are important for the correct interpretation of this widely used medical technique, which may have novel applications in diagnosis and treatment monitoring of aging and skin diseases.

1 June 2017 in Russian Journal of Nondestructive Testing
Verified
Journal Article
Closed access
PDF file
Oleg Viktorovich BashkovOleg Viktorovich Bashkov
Oleg Viktorovich Bashkov
Roman RomashkoRoman Romashko
Roman Romashko
VZV. I. Zaikov
V. I. Zaikov
Sergey V PaninSergey V Panin
Sergey V Panin
MBM. N. Bezruk
M. N. Bezruk
Oleg Viktorovich BashkovOleg Viktorovich Bashkov
Oleg Viktorovich Bashkov
Results of the analysis of acoustic-emission signals generated due to ultrasonic waves propagating in a polymer composite material and registered with piezoelectric and fiber-optic sensors are presented. The fiber-optic sensors were arranged into an adaptive interferometer based on using a dynamic hologram formed in a photorefractive crystal. Reducing the setpoint fading has made it possible to improve the noise immunity and sensitivity of the measurement system when using an adaptive interferometer on a photorefractive crystal. Optical fibers in the interferometer’s measurement system served as sensors of ultrasonic waves and were built into a polymer composite material when the sample was manufactured. The sample was a rectangular plate made of a multilayer fiberglass material. It has been discovered that the sensitivity of the adaptive interferometer makes it possible to detect acoustic- emission signals generated by a Hsu–Nielsen source. When determining the speed of sound in the polymer composite material, peculiarities of registering a group wave by fiber-optic sensors have been established that are due to the anisotropy of the medium the wave propagates in and the distributed character of sensor placement in the studied composite material. The wavelet transform has been used to separate the informative component of the wanted signal.