Paweł Artur Mazurek

Dr. Paweł Artur Mazurek

Lublin University of Technology, Faculty of Electrical Engineering and Computer Science
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2017 in Annals of Agricultural and Environmental Medicine
Verified
Journal Article
Open access
Artur WdowiakArtur Wdowiak
Artur Wdowiak
PMPaweł Artur Mazurek
Paweł Artur Mazurek
AWAnita Wdowiak
Anita Wdowiak
IBIwona Bojar
Iwona Bojar
Electromagnetic radiation (EMR) emitting from the natural environment, as well as from the use of industrial and everyday appliances, constantly influence the human body. The effect of this type of energy on living tissues may exert various effects on their functioning, although the mechanisms...

30 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
PMPaweł Artur Mazurek
Paweł Artur Mazurek
ACAleksander Chudy
Aleksander Chudy
The electric vehicles (EVs) could potentially have a significant impact on power quality parameters and distribution networks as they are non-linear loads and their charging might result in tremendous power demand. When connected to the utility grid, a large number of EV charging stations from different manufacturers might create significant harmonic current emissions, impact the voltage profile, and eventually affect the power quality. Nevertheless, practical examples of disturbances from charging stations have not been made public. This paper aims to clarify the characteristics of conductive disturbances and levels of current harmonics generated by charging station and their severity on the quality of electric energy. The analysis was based on tests of a prototype station of an EV charging station integrated with a LED street light. The tests concern the determination of current harmonics and the values of conductive electromagnetic disturbances in the 150 kHz–30 MHz range. The test results of the prototype charger with observed exceedances of current harmonics (25th–39th range) and conducted interference exceedances are comprehensively described. After applying filtering circuits to the final version of the station, retesting in an accredited laboratory showed qualitative compliance.

1 November 2019 in Journal of Ecological Engineering
Verified
Journal Article
Open access
ACAleksander Chudy
Aleksander Chudy
PMPaweł Artur Mazurek
Paweł Artur Mazurek
Electric vehicles (EVs) play a significant role in a gradual shift towards low-carbon society. However. the impact of electromobility on a power system includes different power quality problems that need to be mitigated. Power Quality Analyzer SONEL PQM-700 was used for the measurement and analysis of the power quality parameters during slow charging (at similar to 11A, similar to 8,3 A and similar to 5,5 A) of a BMW i3 electric vehicle. The read-out mode of the device was considered. The state of EV charge was 30%. The measurements focused on the values of supply voltage, drawn current, harmonics, values of active, reactive and apparent power. In this study, type 2 connector was used to charge the EV. The power quality parameters during the BMW i3 charging were within limits, not a single parameter was exceeded. Additionally. the current state of electric vehicle charging methods and EV charging infrastructure was described and power conditioning solutions were presented.

30 July 2022 in Energies
Verified
Journal Article
Open access
PDF file
ACAleksander Chudy
Aleksander Chudy
PHPiotr Hołyszko
Piotr Hołyszko
PMPaweł Artur Mazurek
Paweł Artur Mazurek
The subject of this study was a distribution substation that feeds 14 fast DC chargers (80 kW) located at the bus depot in Lublin, Poland. The voltage variations were determined to be within the PN-EN 50160 standard limit values (±10% Un). There were several events registered when 4th, 6th, 8th, and 10th voltage harmonics were above the PN-EN 50160 limit during the charging of the electric buses. The obtained maximum 10 min average values of the total voltage harmonic distortion (THD) were 3.36%, 2.27%, and 2.89% for the first, second, and third phase, respectively, i.e., below the limit value of 8% required by PN-EN 50160. Due to the exceedance of the 6th voltage harmonic, the PN-EN 50160 requirements were not met.

5 December 2018 in PRZEGLĄD ELEKTROTECHNICZNY
Verified
Journal Article
Closed access
PMPaweł Artur Mazurek
Paweł Artur Mazurek
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informuj

29 May 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PMPaweł Artur Mazurek
Paweł Artur Mazurek
This paper presents an analysis of electromagnetic disturbance interactions inside the three-phase gliding arc plasma generation installation. This is the main part of the electromagnetic compatibility analysis of the reactor installation. All elements of the nonthermal plasma installation are described from the point of view of disturbance generation and their influence on the power supply system. The analysis is based on the results of tests carried out in accordance with the guidelines of the electromagnetic compatibility (EMC) Directive and harmonised standards. The disturbances measured are large, over 20 dB above the limits. The disturbances measured allow valid conclusions to be reached in relation to this type of installation. The implication is the need for plasma reactors designed with elements that reduce radiated and conducted interference.