Bone drilling is a common procedure in Medicine, mainly in traumatology and orthopedic procedure for fractures fixation and in reconstructive surgery. The success of this surgical procedure is dependent on many factors, namely, on heat generation control during the bone drilling. The main concern in bone drilling is the mechanical and thermal damage of the bone induced by inappropriate parameters such as drill speed and feed-rate during the drilling. This study focuses on the temperature generated during drilling of cortical bone tissue (bovine origin) and solid rigid polyurethane foams with similar mechanical properties to the human bone tissue. Different parameters such as drill speed, feed-rate and hole depth were tested. All results showed that improvement of the drilling parameters and the drill temperatures can be estimated. It was concluded that when the drill speed and feed-rate were higher, the bone temperature increase was lower. The obtained results of temperature in the drilling process of polyurethane foam blocks or bovine bone were compared with a good agreement in between both.
This study aims to comprehensively assess the accuracy and precision of five different devices and by incorporating a variety of analytical approaches for measuring countermovement jump height: Qualisys motion system; Force platform; Ergojump; an Accelerometer, and self-made Abalakow jump belt. Twenty-seven male and female physical education students (23.5 ± 3.8 years; height 170 ± 9.1 cm and body mass 69.1 ± 11.4 kg) performed three countermovement jumps simultaneously measured using five devices. The 3D measured displacement obtained through the Qualisys device was considered in this study as the reference value. The best accuracy (difference from 3D measured displacement) and precision (standard deviation of differences) for countermovement jump measurement was found using the Abalakow jump belt (0.8 ± 14.7 mm); followed by the Force platform when employing a double integration method (1.5 ± 13.9 mm) and a flight-time method employed using Qualisys motion system data (6.1 ± 17.1 mm). The least accuracy was obtained for the Ergojump (−72.9 mm) employing its analytical tools and then for the accelerometer and Force platform using flight time approximations (−52.8 mm and −45.3 mm, respectively). The worst precision (±122.7 mm) was obtained through double integration of accelerometer acceleration data. This study demonstrated that jump height measurement accuracy is both device and analytical-approach-dependent and that accuracy and precision in jump height measurement are achievable with simple, inexpensive equipment such as the Abalakow jump belt.
13 January 2017 in Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications
In bone drilling, the temperature and the level of stresses at the bone tissue are function of the drilling parameters. If certain thresholds are exceeded, irreversible damages may occur on the bone tissue. One of the main challenges in the drilling process is to control the associated parameters and even more important, to avoid the surrounding tissue damage. In this study, a dynamic numerical model is developed to determine the thermo-mechanical stresses generated during the bone drilling, using the finite element method. The numerical model incorporates the geometric and dynamic characteristics involved in the drilling processes, as well the developed temperature inside the material. The numerical analysis has been validated by experimental tests using polyurethane foam materials with similar mechanical properties to the human bone. Results suggest that a drill bit with lower drill speed and higher feed rate can reduce the strains and stresses in bone during the drilling process. The proposed numerical model reflected adequately the experimental results and could be useful in determination of optimal drilling conditions that minimise the bone injuries.
Individualized, serial production of innovative implants is a major area of application for additive manufacturing in the field of medicine. Individualized healthcare requires faster delivery of the implant to the clinic or hospital facility. The total manufacturing process, including data generation using 3D drawings, imaging techniques, 3D printing and post-processing, usually takes up to a week, especially implants from risk class III, which requires qualified equipment and a validated process. In this study, we describe how to develop a new biomechanical model for dental implants from its conception for the patent to the final product which is ready to be manufactured using additive manufacturing. The benefits and limitations of titanium metal printing for dental implant prototypes are presented by the authors.