With attention increasing regarding the level of air pollution in different metropolitan and industrial areas worldwide, interest in expanding the monitoring networks by low-cost air quality sensors is also increasing. Although the role of these small and affordable sensors is rather supplementary, determination of the measurement uncertainty is one of the main questions of their applicability because there is no certificate for quality assurance of these non-reference technologies. This paper presents the results of almost one-year field testing measurements, when the data from different low-cost sensors (for SO2, NO2, O3, and CO: Cairclip, Envea, FR; for PM1, PM2.5, and PM10: PMS7003, Plantower, CHN, and OPC-N2, Alphasense, UK) were compared with co-located reference monitors used within the Czech national ambient air quality monitoring network. The results showed that in addition to the given reduced measurement accuracy of the sensors, the data quality depends on the early detection of defective units and changes caused by the effect of meteorological conditions (effect of air temperature and humidity on gas sensors and effect of air humidity with condensation conditions on particle counters), or by the interference of different pollutants (especially in gas sensors). Comparative measurement is necessary prior to each sensor’s field applications.
Urban air quality is an important part of human well-being, and its detailed and precise modeling is important for efficient urban planning. In this study the potential sources of errors in large eddy simulation (LES) runs of the PALM model in stable conditions for a high-traffic residential area in Prague, Czech Republic, with a focus on street canyon ventilation, are investigated. The evaluation of the PALM model simulations against observations obtained during a dedicated campaign revealed unrealistically high concentrations of modeled air pollutants for a short period during a winter inversion episode. To identify potential reasons, the sensitivities of the model to changes in meteorological boundary conditions and adjustments of model parameters were tested. The model adaptations included adding the anthropogenic heat from cars, setting a bottom limit of the subgrid-scale turbulent kinetic energy (TKE), adjusting the profiles of parameters of the synthetic turbulence generator in PALM, and limiting the model time step. The study confirmed the crucial role of the correct meteorological boundary conditions for realistic air quality modeling during stable conditions. Besides this, the studied adjustments of the model parameters proved to have a significant impact in these stable conditions, resulting in a decrease in concentration overestimation in the range 30 %–66 % while exhibiting a negligible influence on model results during the rest of the episode. This suggested that the inclusion or improvement of these processes in PALM is desirable despite their negligible impact in most other conditions. Moreover, the time step limitation test revealed numerical inaccuracies caused by discretization errors which occurred during such extremely stable conditions.
As part of the TURBAN project, the “Legerova campaign” investigated air quality and meteorology in a traffic-dense area of Prague, Czech Republic, from 30 May 2022 to 28 March 2023. The study deployed a network of 20 low-cost sensor (LCS) stations to measure NO2, O3, PM10 and PM2.5 concentrations, complemented by advanced meteorological instruments such as a microwave radiometer and Doppler lidar. Ensuring data quality from LCS measurements presented significant challenges. Initial field tests at a reference monitoring station revealed strong correlations between raw LCS and reference data (r > 0.90 for NO2 and PM2.5, r > 0.80 for O3 and PM10). However, individual biases were observed. Applying the multivariate adaptive regression splines (MARS) method effectively reduced biases and enhanced alignment with reference measurements for all pollutants (R2 0.88–0.97). During the campaign, sensor ageing and technical issues were identified through double mass curve analysis and final field testing. The highest NO2 concentrations were recorded in streets with dense building blocks and traffic lights, corresponding to peak traffic patterns (with medians of concentrations 20–34 ppb). Aerosol concentrations were generally low (medians of PM10 < 25 µg m−3 at all sites), with less temporal and spatial variability than NO2. Elevated PM10 and PM2.5 levels occurred primarily during temperature inversions, often linked to local sources, and during a short, non-local episode. This study highlights the MARS method as a reliable tool for field calibration of LCS networks and provides valuable data on urban air quality and its dynamics with high spatiotemporal resolution.