The performance of intelligent electromyogram (EMG)-driven prostheses, functioning as artificial alternatives to missing limbs, is influenced by several dynamic factors including: electrode position shift, varying muscle contraction level, forearm orientation, and limb position. The impact of these factors on EMG pattern recognition has been previously studied in isolation, with the combined effect of these factors being understudied. However, it is likely that a combination of these factors influences the accuracy. We investigated the combined effect of two dynamic factors, namely, forearm orientation and muscle contraction levels, on the generalizability of the EMG pattern recognition. A number of recent time- and frequency-domain EMG features were utilized to study the EMG classification accuracy. Twelve intact-limbed and one bilateral transradial (below-elbow) amputee subject were recruited. They performed six classes of wrist and hand movements at three muscular contraction levels with three forearm orientations (nine conditions). Results indicate that a classifier trained by features that quantify the angle, rather than amplitude, of the muscle activation patterns perform better than other feature sets across different contraction levels and forearm orientations. In addition, a classifier trained with the EMG signals collected at multiple forearm orientations with medium muscular contractions can generalize well and achieve classification accuracies of up to 91%. Furthermore, inclusion of an accelerometer to monitor wrist movement further improved the EMG classification accuracy. The results indicate that the proposed methodology has the potential to improve robustness of myoelectric pattern recognition
Computer vision-based assistive technology solutions can revolutionise the quality of care for people with sensorimotor disorders. The goal of this work was to enable trans-radial amputees to use a simple, yet efficient, computer vision system to grasp and move common household objects with a two-channel myoelectric prosthetic hand. We developed a deep learning-based artificial vision system to augment the grasp functionality of a commercial prosthesis. Our main conceptual novelty is that we classify objects with regards to the grasp pattern without explicitly identifying them or measuring their dimensions. A convolutional neural network (CNN) structure was trained with images of over 500 graspable objects. For each object, 72 images, at [Formula: see text] intervals, were available. Objects were categorised into four grasp classes, namely: pinch, tripod, palmar wrist neutral and palmar wrist pronated. The CNN setting was first tuned and tested offline and then in realtime with objects or object views that were not included in the training set. The classification accuracy in the offline tests reached [Formula: see text] for the seen and [Formula: see text] for the novel objects; reflecting the generalisability of grasp classification. We then implemented the proposed framework in realtime on a standard laptop computer and achieved an overall score of [Formula: see text] in classifying a set of novel as well as seen but randomly-rotated objects. Finally, the system was tested with two trans-radial amputee volunteers controlling an i-limb UltraTM prosthetic hand and a motion controlTM prosthetic wrist; augmented with a webcam. After training, subjects successfully picked up and moved the target objects with an overall success of up to [Formula: see text]. In addition, we show that with training, subjects' performance improved in terms of time required to accomplish a block of 24 trials despite a decreasing level of visual feedback. The proposed design constitutes a substantial conceptual improvement for the control of multi-functional prosthetic hands. We show for the first time that deep-learning based computer vision systems can enhance the grip functionality of myoelectric hands considerably.
Correlation structure in the activity of muscles across movements is often interpreted as evidence for low-level, hardwired constraints on upper-limb function. However, muscle synergies may also emerge from optimal strategies to achieve high-level task goals within a redundant control space. To distinguish these contrasting interpretations, we examined the structure of muscle variability during operation of a myoelectric interface in which task constraints were dissociated from natural limb biomechanics. We found that, with practice, human subjects learned to shape patterns of covariation between arbitrary pairs of hand and forearm muscles appropriately for elliptical targets whose orientation varied on a trial-by-trial basis. Thus, despite arriving at the same average location in the effector space, performance was improved by buffering variability into those dimensions that least impacted task success. Task modulation of beta-frequency intermuscular coherence indicated that differential recruitment of divergent corticospinal pathways contributed to positive correlations among muscles. However, this feedforward mechanism could not account for negative correlations observed in the presence of visual feedback. A second experiment revealed the development of fast, target-dependent visual responses consistent with “minimum intervention” control correcting predominantly task-relevant errors. Together, these mechanisms contribute to the dynamic emergence of task-specific muscle synergies appropriate for a wide range of abstract task goals.
The probability density function (PDF) of the surface electromyogram (EMG) signals has been modelled with Gaussian and Laplacian distribution functions. However, a general consensus upon the PDF of the EMG signals is yet to be reached, because not only are there several biological factors that can influence this distribution function, but also different analysis techniques can lead to contradicting results. Here, we recorded the EMG signal at different isometric muscle contraction levels and characterised the probability distribution of the surface EMG signal with two statistical measures: bicoherence and kurtosis. Bicoherence analysis did not help to infer the PDF of measured EMG signals. In contrast, with kurtosis analysis we demonstrated that the EMG PDF at isometric, non-fatiguing, low contraction levels is super-Gaussian. Moreover, kurtosis analysis showed that as the contraction force increases the surface EMG PDF tends to a Gaussian distribution.
Magnetism‐based systems are widely utilized for sensing and imaging biological phenomena, for example, the activity of the brain and the heart. Magnetomyography (MMG) is the study of muscle function through the inquiry of the magnetic signal that a muscle generates when contracted. Within the last few decades, extensive effort has been invested to identify, characterize and quantify the magnetomyogram signals. However, it is still far from a miniaturized, sensitive, inexpensive and low‐power MMG sensor. Herein, the state‐of‐the‐art magnetic sensing technologies that have the potential to realize a low‐profile implantable MMG sensor are described. The technical challenges associated with the detection of the MMG signals, including the magnetic field of the Earth and movement artifacts are also discussed. Then, the development of efficient magnetic technologies, which enable sensing pico‐Tesla signals, is advocated to revitalize the MMG technique. To conclude, spintronic‐based magnetoresistive sensing can be an appropriate technology for miniaturized wearable and implantable MMG systems.
Powered hand prostheses with many degrees of freedom are moving from research into the market for prosthetics. In order to make use of the prostheses’ full functionality, it is essential to study efficient ways of high dimensional myoelectric control. Human subjects can rapidly learn to employ electromyographic (EMG) activity of several hand and arm muscles to control the position of a cursor on a computer screen, even if the muscle-cursor map contradicts directions in which the muscles would act naturally. But can a similar control scheme be translated into real-time operation of a dexterous robotic hand? We found that despite different degrees of freedom in the effector output, the learning process for controlling a robotic hand was surprisingly similar to that for a virtual two-dimensional cursor. Control signals were derived from the EMG in two different ways, with a linear and a Bayesian filter, to test how stable user intentions could be conveyed through them. Our analysis indicates that without visual feedback, control accuracy benefits from filters that reject high EMG amplitudes. In summary, we conclude that findings on myoelectric control principles, studied in abstract, virtual tasks can be transferred to real-life prosthetic applications.