Mohamad Faizal Abd Rahman

Mohamad Faizal Abd Rahman


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
NHNor Shahanim Mohamad Hadis
Nor Shahanim Mohamad Hadis
AAAbd Manaf Asrulnizam
Abd Manaf Asrulnizam
MRMohamad Faizal Abd Rahman
Mohamad Faizal Abd Rahman
SNSiti Hawa Ngalim
Siti Hawa Ngalim
TTTang TH
Tang TH
SHSukreen Hana Herman
Sukreen Hana Herman
Non-structural protein 1 (NS1 protein) is becoming a commonplace biomarker for the diagnostic of early detection of dengue. In this study, we sought to use a label-free approach of detecting NS1 protein by harnessing fluidic-based memristor sensor. The sensor was fabricated using sol-gel spin coating technique, by which TiO2 thin film is coated on the surface of Indium tin oxide (ITO) and a glass substrate. The sensor was then functionalized with glycidoxypropyl-trimethoxysilane (GPTS), acting as antibody for NS1. The addition of the target NS1 formed an antibody-antigen complex which altered the physical and electrical properties in sensing region. Sensing of the sensor is incumbent upon the measurement of Off-On resistance ratio. Imaging with Field Emission Scanning Electron Microscope (FESEM) evinced the successful immobilization of the antibody and the subsequent capture of the NS1 protein by the immobilized antibody. The detection limit actualized by the developed sensor was 52 nM and the diameter of 2 mm gives the most optimal measurement. The developed sensor demonstrated an immense potential towards the development of label-free diagnostic of early dengue infection.

29 May 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
IHIntan Sue Liana Abdul Hamid
Intan Sue Liana Abdul Hamid
BKBeh Khi Khim
Beh Khi Khim
SHSofiyah Sal Hamid
Sofiyah Sal Hamid
MRMohamad Faizal Abd Rahman
Mohamad Faizal Abd Rahman
AAAbd Manaf Asrulnizam
Abd Manaf Asrulnizam
Three-dimensional (3D) microstructures have been exploited in various applications of microfluidic devices. Multilevel structures in micromixers are among the essential structures in microfluidic devices that exploit 3D microstructures for different tasks. The efficiency of the micromixing process is thus crucial, as it affects the overall performance of a microfluidic device. Microstructures are currently fabricated by less effective techniques due to a slow point-to-point and layer-by-layer pattern exposure by using sophisticated and expensive equipment. In this work, a grayscale photolithography technique is proposed with the capability of simultaneous control on lateral and vertical dimensions of microstructures in a single mask implementation. Negative photoresist SU8 is used for mould realisation with structural height ranging from 163.8 to 1108.7 µm at grayscale concentration between 60% to 98%, depending on the UV exposure time. This technique is exploited in passive micromixers fabrication with multilevel structures to study the mixing performance. Based on optical absorbance analysis, it is observed that 3D serpentine structure gives the best mixing performance among other types of micromixers.

19 August 2021 in Sensors
Verified
Journal Article
Open access
PDF file
KAKhairul Azman Ahmad
Khairul Azman Ahmad
MRMohamad Faizal Abd Rahman
Mohamad Faizal Abd Rahman
KZKhairu Anuar Mohamed Zain
Khairu Anuar Mohamed Zain
MHMuhammad Naim Haron
Muhammad Naim Haron
AAAbd Manaf Asrulnizam
Abd Manaf Asrulnizam
In acoustic receiver design, the receiving sensitivity and bandwidth are two primary parameters that determine the performance of a device. The trade-off between sensitivity and bandwidth makes the design very challenging, meaning it needs to be fine-tuned to suit specific applications. The ability to design a PMUT with high receiving sensitivity and a wide bandwidth is crucial to allow a wide spectrum of transmitted frequencies to be efficiently received. This paper presents a novel structure involving a double flexural membrane with a fluidic backing layer based on an in-plane polarization mode to optimize both the receiving sensitivity and frequency bandwidth for medium-range underwater acoustic applications. In this structure, the membrane material and electrode configuration are optimized to produce good receiving sensitivity. Simultaneously, a fluidic backing layer is introduced into the double flexural membrane to increase the bandwidth. Several piezoelectric membrane materials and various electrode dimensions were simulated using finite element analysis (FEA) techniques to study the receiving performance of the proposed structure. The final structure was then fabricated based on the findings from the simulation work. The pulse–echo experimental method was used to characterize and verify the performance of the proposed device. The proposed structure was found to have an improved bandwidth of 56.6% with a receiving sensitivity of −1.8864 dB rel 1 V µPa. For the proposed device, the resonance frequency and center frequency were 600 and 662.5 kHz, respectively, indicating its suitability for the targeted frequency range.