In this review, the condensation HTCs (heat transfer coefficients) and pressure drop characteristics of some major low-global-warming-potential (GWP) refrigerants alternative to R-134a such as R-1234ze(E), R-1234ze(Z), R-1234yf, R-513A, and R-450A are reviewed. The thermofluids’ characteristics inside/outside a tube, minichannel, microfin tube, and plate heat exchanger are examined. In addition, several other refrigerants attributed to low GWP are also included in the present review. The experimental/numerical/simulation results’ analysis reveals that condensation HTCs and pressure drop characteristics depend on several parameters such as thermodynamics and transport properties of the working fluid, mass flux of the refrigerants, heat flux, saturation temperature, vapor quality, flow patterns, flow conditions, orientation of the condensing geometry, and condensation geometry (shape, size, and smooth/enhanced).
In the present experimental study, nucleate pool boiling heat transfer measurements of two high-flux tubes (sample A and sample B) were conducted at atmospheric pressure with HFE-7200 as the working fluid. Both high-flux tubes were made from a sintered Cu-Ni (high-flux) alloy powder. The porous high-flux surface was coated inside the test tube and it is tested within the heat flux ranging from 2.6 to 86 kW/m2. The major difference between sample A and sample B was the coating thickness, where sample B (0.6 mm) was much larger than that of sample A (0.07 mm). Both tubes showed about three times enhancement in heat transfer coefficient (HTC) when compared to plain tube. Even though sample B contained a higher HTC than sample A, it also revealed a faster level-off phenomenon regarding the HTC vs. wall superheat. The major parameter which characterizes the boiling performance of high-flux tube was the ratio of coating thickness to pore diameter which also yielded different trends upon HTC vs. wall superheat amid sample A and B. It was found that the porous based Nishikawa correlation can well predict the performance of sample A but not sample B. This is because the ratio of coating thickness to pore diameter is far outside the applicable range of the Nishikawa correlation. Hence, a modified Nishikawa correlation is proposed. The predicted capability of the proposed modified Nishikawa correlation against sample A and sample for HTC was within ±28% deviation. The standard mean deviation of the Nishikawa correlation with experimental data for sample A and sample B was 0.302 (12.48%) and 5.64 (73%), respectively.
9 October 2022 in International Journal of Refrigeration