Pio Fina

Mr. Pio Fina


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 February 2021 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
Antonella NannavecchiaAntonella Nannavecchia
Antonella Nannavecchia
FGFrancesco Girardi
Francesco Girardi
PFPio Fina
Pio Fina
MSMichele Scalera
Michele Scalera
Giovanni DimauroGiovanni Dimauro
Giovanni Dimauro
The automated detection of suspicious anomalies in electrocardiogram (ECG) recordings allows frequent personal heart health monitoring and can drastically reduce the number of ECGs that need to be manually examined by the cardiologists, excluding those classified as normal, facilitating healthcare decision-making and reducing a considerable amount of time and money. In this paper, we present a system able to automatically detect the suspect of cardiac pathologies in ECG signals from personal monitoring devices, with the aim to alert the patient to send the ECG to the medical specialist for a correct diagnosis and a proper therapy. The main contributes of this work are: (a) the implementation of a binary classifier based on a 1D-CNN architecture for detecting the suspect of anomalies in ECGs, regardless of the kind of cardiac pathology; (b) the analysis was carried out on 21 classes of different cardiac pathologies classified as anomalous; and (c) the possibility to classify anomalies even in ECG segments containing, at the same time, more than one class of cardiac pathologies. Moreover, 1D-CNN based architectures can allow an implementation of the system on cheap smart devices with low computational complexity. The system was tested on the ECG signals from the MIT-BIH ECG Arrhythmia Database for the MLII derivation. Two different experiments were carried out, showing remarkable performance compared to other similar systems. The best result showed high accuracy and recall, computed in terms of ECG segments and even higher accuracy and recall in terms of patients alerted, therefore considering the detection of anomalies with respect to entire ECG recordings.

8 June 2020 in Electronics
Verified
Journal Article
Open access
PDF file
Giovanni DimauroGiovanni Dimauro
Giovanni Dimauro
Vitoantonio BevilacquaVitoantonio Bevilacqua
Vitoantonio Bevilacqua
PFPio Fina
Pio Fina
Domenico BuongiornoDomenico Buongiorno
Domenico Buongiorno
Antonio BrunettiAntonio Brunetti
Antonio Brunetti
MGMatteo Gelardi
Matteo Gelardi
Cytological study of the nasal mucosa (also known as rhino-cytology) represents an important diagnostic aid that allows highlighting of the presence of some types of rhinitis through the analysis of cellular features visible under a microscope. Nowadays, the automated detection and classification of cells benefit from the capacity of deep learning techniques in processing digital images of the cytological preparation. Even though the results of such automatic systems need to be validated by a specialized rhino-cytologist, this technology represents a valid support that aims at increasing the accuracy of the analysis while reducing the required time and effort. The quality of the rhino-cytological preparation, which is clearly important for the microscope observation phase, is also fundamental for the automatic classification process. In fact, the slide-preparing technique turns out to be a crucial factor among the multiple ones that may modify the morphological and chromatic characteristics of the cells. This paper aims to investigate the possible differences between direct smear (SM) and cytological centrifugation (CYT) slide-preparation techniques, in order to preserve image quality during the observation and cell classification phases in rhino-cytology. Firstly, a comparative study based on image analysis techniques has been put forward. The extraction of densitometric and morphometric features has made it possible to quantify and describe the spatial distribution of the cells in the field images observed under the microscope. Statistical analysis of the distribution of these features has been used to evaluate the degree of similarity between images acquired from SM and CYT slides. The results prove an important difference in the observation process of the cells prepared with the above-mentioned techniques, with reference to cell density and spatial distribution: the analysis of CYT slides has been more difficult than of the SM ones due to the spatial distribution of the cells, which results in a lower cell density than the SM slides. As a marginal part of this study, a performance assessment of the computer-aided diagnosis (CAD) system called Rhino-cyt has also been carried out on both groups of image slide types.

30 June 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Giovanni DimauroGiovanni Dimauro
Giovanni Dimauro
DPDavide Di Pierro
Davide Di Pierro
FDFrancesca Deperte
Francesca Deperte
Lorenzo SimoneLorenzo Simone
Lorenzo Simone
PFPio Fina
Pio Fina
Rhinology studies the anatomy, physiology, and diseases affecting the nasal region—one of the most modern techniques to diagnose these diseases is nasal cytology, which involves microscopic analysis of the cells contained in the nasal mucosa. The standard clinical protocol regulates the compilation of the rhino-cytogram by observing, for each slide, at least 50 fields under an optical microscope to evaluate the cell population and search for cells important for diagnosis. The time and effort required for the specialist to analyze a slide are significant. In this paper, we present a smartphones-based system to support cell segmentation on images acquired directly from the microscope. Then, the specialist can analyze the cells and the other elements extracted directly or, alternatively, he can send them to Rhino-cyt, a server system recently presented in the literature, that also performs the automatic cell classification, giving back the final rhinocytogram. This way he significantly reduces the time for diagnosing. The system crops cells with sensitivity = 0.96, which is satisfactory because it shows that cells are not overlooked as false negatives are few, and therefore largely sufficient to support the specialist effectively. The use of traditional image processing techniques to preprocess the images also makes the process sustainable from the computational point of view for medium–low end architectures and is battery-efficient on a mobile phone.