Antonio Brunetti

Prof. Antonio Brunetti

Department of Electrical and Information Engineering, Polytechnic University of Bari, Bari, Puglia, Italy
orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2018 in Neurocomputing
Verified
Journal Article
Closed access
Antonio BrunettiAntonio Brunetti
Antonio Brunetti
Domenico BuongiornoDomenico Buongiorno
Domenico Buongiorno
GTGianpaolo Francesco Trotta
Gianpaolo Francesco Trotta
Vitoantonio BevilacquaVitoantonio Bevilacqua
Vitoantonio Bevilacqua

1 January 2023 in IEEE Access
Verified
Journal Article
Open access
Michela PrunellaMichela Prunella
Michela Prunella
RSRoberto Maria Scardigno
Roberto Maria Scardigno
Domenico BuongiornoDomenico Buongiorno
Domenico Buongiorno
Antonio BrunettiAntonio Brunetti
Antonio Brunetti
NLNicola Longo
Nicola Longo
Vitoantonio BevilacquaVitoantonio Bevilacqua
Vitoantonio Bevilacqua
Automatic vision-based inspection systems have played a key role in product quality assessment for decades through the segmentation, detection, and classification of defects. Historically, machine learning frameworks, based on hand-crafted feature extraction, selection, and validation, counted on a combined approach of parameterized image processing algorithms and explicated human knowledge. The outstanding performance of deep learning (DL) for vision systems, in automatically discovering a feature representation suitable for the corresponding task, has exponentially increased the number of scientific articles and commercial products aiming at industrial quality assessment. In such a context, this article reviews more than 220 relevant articles from the related literature published until February 2023, covering the recent consolidation and advances in the field of fully-automatic DL-based surface defects inspection systems, deployed in various industrial applications. The analyzed papers have been classified according to a bi-dimensional taxonomy, that considers both the specific defect recognition task and the employed learning paradigm. The dependency on large and high-quality labeled datasets and the different neural architectures employed to achieve an overall perception of both well-visible and subtle defects, through the supervision of fine or/and coarse data annotations have been assessed. The results of our analysis highlight a growing research interest in defect representation power enrichment, especially by transferring pre-trained layers to an optimized network and by explaining the network decisions to suggest trustworthy retention or rejection of the products being evaluated.

12 December 2019 in BMC Medical Informatics and Decision Making
Verified
Journal Article
Open access
PDF file
Domenico BuongiornoDomenico Buongiorno
Domenico Buongiorno
Ilaria BortoneIlaria Bortone
Ilaria Bortone
GCGiacomo Donato Cascarano
Giacomo Donato Cascarano
GTGianpaolo Francesco Trotta
Gianpaolo Francesco Trotta
Antonio BrunettiAntonio Brunetti
Antonio Brunetti
Vitoantonio BevilacquaVitoantonio Bevilacqua
Vitoantonio Bevilacqua
Background: Assessment and rating of Parkinson’s Disease (PD) are commonly based on the medical observation of several clinical manifestations, including the analysis of motor activities. In particular, medical specialists refer to the MDS-UPDRS (Movement Disorder Society – sponsored revision of Unified Parkinson’s Disease Rating Scale) that is the most widely used clinical scale for PD rating. However, clinical scales rely on the observation of some subtle motor phenomena that are either difficult to capture with human eyes or could be misclassified. This limitation motivated several researchers to develop intelligent systems based on machine learning algorithms able to automatically recognize the PD. Nevertheless, most of the previous studies investigated the classification between healthy subjects and PD patients without considering the automatic rating of different levels of severity. Methods: In this context, we implemented a simple and low-cost clinical tool that can extract postural and kinematic features with the Microsoft Kinect v2 sensor in order to classify and rate PD. Thirty participants were enrolled for the purpose of the present study: sixteen PD patients rated according to MDS-UPDRS and fourteen healthy paired subjects. In order to investigate the motor abilities of the upper and lower body, we acquired and analyzed three main motor tasks: (1) gait, (2) finger tapping, and (3) foot tapping. After preliminary feature selection, different classifiers based on Support Vector Machine (SVM) and Artificial Neural Networks (ANN) were trained and evaluated for the best solution. Results: Concerning the gait analysis, results showed that the ANN classifier performed the best by reaching 89.4% of accuracy with only nine features in diagnosis PD and 95.0% of accuracy with only six features in rating PD severity. Regarding the finger and foot tapping analysis, results showed that an SVM using the extracted features was able to classify healthy subjects versus PD patients with great performances by reaching 87.1% of accuracy. The results of the classification between mild and moderate PD patients indicated that the foot tapping features were the most representative ones to discriminate (81.0% of accuracy). Conclusions: The results of this study have shown how a low-cost vision-based system can automatically detect subtle phenomena featuring the PD. Our findings suggest that the proposed tool can support medical specialists in the assessment and rating of PD patients in a real clinical scenario.

1 February 2023 in Journal of Neural Engineering
Verified
Journal Article
Open access
ESElena Sibilano
Elena Sibilano
Antonio BrunettiAntonio Brunetti
Antonio Brunetti
Domenico BuongiornoDomenico Buongiorno
Domenico Buongiorno
MLMichael Lassi
Michael Lassi
AGAntonello Grippo
Antonello Grippo
Vitoantonio BevilacquaVitoantonio Bevilacqua
Vitoantonio Bevilacqua
Objective. This study aims to design and implement the first deep learning (DL) model to classify subjects in the prodromic states of Alzheimer’s disease (AD) based on resting-state electroencephalographic (EEG) signals. Approach. EEG recordings of 17 healthy controls (HCs), 56 subjective cognitive decline (SCD) and 45 mild cognitive impairment (MCI) subjects were acquired at resting state. After preprocessing, we selected sections corresponding to eyes-closed condition. Five different datasets were created by extracting delta, theta, alpha, beta and delta-to-theta frequency bands using bandpass filters. To classify SCD vs MCI and HC vs SCD vs MCI, we propose a framework based on the transformer architecture, which uses multi-head attention to focus on the most relevant parts of the input signals. We trained and validated the model on each dataset with a leave-one-subject-out cross-validation approach, splitting the signals into 10 s epochs. Subjects were assigned to the same class as the majority of their epochs. Classification performances of the transformer were assessed for both epochs and subjects and compared with other DL models. Main results. Results showed that the delta dataset allowed our model to achieve the best performances for the discrimination of SCD and MCI, reaching an Area Under the ROC Curve (AUC) of 0.807, while the highest results for the HC vs SCD vs MCI classification were obtained on alpha and theta with a micro-AUC higher than 0.74. Significance. We demonstrated that DL approaches can support the adoption of non-invasive and economic techniques as EEG to stratify patients in the clinical population at risk for AD. This result was achieved since the attention mechanism was able to learn temporal dependencies of the signal, focusing on the most discriminative patterns, achieving state-of-the-art results by using a deep model of reduced complexity. Our results were consistent with clinical evidence that changes in brain activity are progressive when considering early stages of AD.

19 March 2020 in Electronics
Verified
Journal Article
Open access
PDF file
Nicola AltiniNicola Altini
Nicola Altini
GCGiacomo Donato Cascarano
Giacomo Donato Cascarano
Antonio BrunettiAntonio Brunetti
Antonio Brunetti
FMFrancescomaria Marino
Francescomaria Marino
MRMaria Teresa Rocchetti
Maria Teresa Rocchetti
Vitoantonio BevilacquaVitoantonio Bevilacqua
Vitoantonio Bevilacqua
The evaluation of kidney biopsies performed by expert pathologists is a crucial process for assessing if a kidney is eligible for transplantation. In this evaluation process, an important step consists of the quantification of global glomerulosclerosis, which is the ratio between sclerotic glomeruli and the overall number of glomeruli. Since there is a shortage of organs available for transplantation, a quick and accurate assessment of global glomerulosclerosis is essential for retaining the largest number of eligible kidneys. In the present paper, the authors introduce a Computer-Aided Diagnosis (CAD) system to assess global glomerulosclerosis. The proposed tool is based on Convolutional Neural Networks (CNNs). In particular, the authors considered approaches based on Semantic Segmentation networks, such as SegNet and DeepLab v3+. The dataset has been provided by the Department of Emergency and Organ Transplantations (DETO) of Bari University Hospital, and it is composed of 26 kidney biopsies coming from 19 donors. The dataset contains 2344 non-sclerotic glomeruli and 428 sclerotic glomeruli. The proposed model consents to achieve promising results in the task of automatically detecting and classifying glomeruli, thus easing the burden of pathologists. We get high performance both at pixel-level, achieving mean F-score higher than 0.81, and Weighted Intersection over Union (IoU) higher than 0.97 for both SegNet and Deeplab v3+ approaches, and at object detection level, achieving 0.924 as best F-score for non-sclerotic glomeruli and 0.730 as best F-score for sclerotic glomeruli.

26 January 2017 in Frontiers in Neuroscience
Verified
Journal Article
Open access
ATAntonio I. Triggiani
Antonio I. Triggiani
Vitoantonio BevilacquaVitoantonio Bevilacqua
Vitoantonio Bevilacqua
Antonio BrunettiAntonio Brunetti
Antonio Brunetti
RLRoberta Lizio
Roberta Lizio
GTGiacomo Tattoli
Giacomo Tattoli
Claudio BabiloniClaudio Babiloni
Claudio Babiloni
Previous evidence showed a 75.5% best accuracy in the classification of 120 Alzheimer’s disease (AD) patients with dementia and 100 matched normal elderly (Nold) subjects based on cortical source current density and linear lagged connectivity estimated by eLORETA freeware from resting state eyes-closed electroencephalographic (rsEEG) rhythms (Babiloni et al., 2016). Specifically, that accuracy was reached using the ratio between occipital delta and alpha1 current density for a linear univariate classifier (receiver operating characteristic curves). Here we tested an innovative approach based on an artificial neural network (ANN) classifier from the same database of rsEEG markers. Frequency bands of interest were delta (2-4 Hz), theta (4-8 Hz Hz), alpha1 (8-10.5 Hz), and alpha2 (10.5-13 Hz). ANN classification showed an accuracy of 77% using the most 4 discriminative rsEEG markers of source current density (delta/alpha1 and theta/alpha1 ratios in posterior cortical lobes). It also showed an accuracy of 72% using the most 4 discriminative rsEEG markers of source lagged linear connectivity (alphas between posterior cortical lobes). With these 8 markers combined, an accuracy of at least 76% was reached. Although these linear rsEEG markers of cortical activity and connectivity unveil different relevant neurophysiological mechanisms underpinning cortical arousal and vigilance in AD patients, they provide quite redundant information for classification purposes. Future AD studies should use ANNs combining the present markers with other linear (i.e. directed transfer function) and nonlinear rsEEG markers to improve the classification accuracy.