Michael James Gatari Gichuru

Prof. Michael James Gatari Gichuru

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2011 in Environmental Science & Policy
Verified
Journal Article
Closed access
PKPatrick Kinney
Patrick Kinney
MGMichael James Gatari Gichuru
Michael James Gatari Gichuru
NVNicole Volavka-Close
Nicole Volavka-Close
NNNicole Ngo
Nicole Ngo
PNPeter K. Ndiba
Peter K. Ndiba
ESElliott Sclar
Elliott Sclar

10 March 2020 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
LCLeigh R. Crilley
Leigh R. Crilley
Ajit SinghAjit Singh
Ajit Singh
LKLouisa Kramer
Louisa Kramer
MSMarvin D. Shaw
Marvin D. Shaw
MAMohammed S. Alam
Mohammed S. Alam
Francis PopeFrancis Pope
Francis Pope
There is considerable interest in using low-cost optical particle counters (OPCs) to supplement existing routine air quality networks that monitor particle mass concentrations. In order to do this, low-cost OPC data need to be comparable with particle mass reference instrumentation; however, there is currently no widely agreed upon methodology to accomplish this. Aerosol hygroscopicity is known to be a key parameter to consider when correcting particle mass concentrations derived from low-cost OPCs, particularly at high ambient relative humidity (RH). Correction factors have been developed that apply κ-Köhler theory to correct for the influence of water uptake by hygroscopic aerosols. We have used datasets of co-located reference particle measurements and low-cost OPC (OPC-N2, Alphasense) measurements, collected in four cities on three continents, to explore the performance of this correction factor. We provide evidence that the elevated particle mass concentrations, reported by the low-cost OPC relative to reference instrumentation, are due to bulk aerosol hygroscopicity under different RH conditions, which is determined by aerosol composition and, in particular, the levels of hygroscopic aerosols (sulfate and nitrate). We exploit measurements made in volcanic plumes in Nicaragua, which are predominantly composed of sulfate aerosol, as a natural experiment to demonstrate this behaviour in the ambient atmosphere; the observed humidogram from these measurements closely resembles the calculated pure sulfuric acid humidogram. The results indicate that the particle mass concentrations derived from low-cost OPCs during periods of high RH (>60 %) need to be corrected for aerosol hygroscopic growth. We employed a correction factor based on κ-Köhler theory and observed that the corrected OPC-N2 PM2.5 mass concentrations were within 33 % of reference measurements at all sites. The results indicated that a κ value derived in situ (using suitable reference instrumentation) would lead to the most accurate correction relative to co-located reference instruments. Applying a κ values from the literature in the correction factor also resulted in improved OPC-N2 performance, with the measurements being within 50 % of the reference values. Therefore, for areas where suitable reference instrumentation for developing a local correction factor is lacking, using a literature κ value can result in a reasonable correction. For locations with low levels of hygroscopic aerosols and low RH values, a simple calibration against gravimetric measurements (using suitable reference instrumentation) would likely be sufficient. Whilst this study generated correction factors specific for the Alphasense OPC-N2 sensor, the calibration methodology developed is likely amenable to other low-cost PM sensors.

26 October 2018 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
Francis PopeFrancis Pope
Francis Pope
MGMichael James Gatari Gichuru
Michael James Gatari Gichuru
DNDavid Ng'ANg'A
David Ng'ANg'A
APAlexander Poynter
Alexander Poynter
RBRhiannon Blake
Rhiannon Blake
East African countries face an increasing threat from poor air quality stemming from rapid urbanization, population growth, and a steep rise in fuel use and motorization rates. With few air quality monitoring systems available, this study provides much needed high temporal resolution data to investigate the concentrations of particulate matter (PM) air pollution in Kenya. Calibrated low-cost optical particle counters (OPCs) were deployed in Kenya in three locations: two in the capital Nairobi and one in a rural location in the outskirts of Nanyuki, which is upwind of Nairobi. The two Nairobi sites consist of an urban background site and a roadside site. The instruments were composed of an AlphaSense OPC-N2 ran with a Raspberry Pi low-cost microcomputer, packaged in a weather-proof box. Measurements were conducted over a 2-month period (February–March 2017) with an intensive study period when all measurements were active at all sites lasting 2 weeks. When collocated, the three OPC-N2 instruments demonstrated good inter-instrument precision with a coefficient of variance of 8.8±2.0 % in the fine particle fraction (PM2.5). The low-cost sensors had an absolute PM mass concentration calibration using a collocated gravimetric measurement at the urban background site in Nairobi. The mean daily PM1 mass concentration measured at the urban roadside, urban background and rural background sites were 23.9, 16.1 and 8.8 µg m−3, respectively. The mean daily PM2.5 mass concentration measured at the urban roadside, urban background and rural background sites were 36.6, 24.8 and 13.0 µg m−3, respectively. The mean daily PM10 mass concentration measured at the urban roadside, urban background and rural background sites were 93.7, 53.0 and 19.5 µg m−3, respectively. The urban measurements in Nairobi showed that PM concentrations regularly exceed WHO guidelines in both the PM10 and PM2.5 size ranges. Following a Lenschow-type approach we can estimate the urban and roadside increments that are applicable to Nairobi (Lenschow et al., 2001). The median urban increment is 33.1 µg m−3 and the median roadside increment is 43.3 µg m−3 for PM2.5. For PM1, the median urban increment is 4.7 µg m−3 and the median roadside increment is 12.6 µg m−3. These increments highlight the importance of both the urban and roadside increments to urban air pollution in Nairobi. A clear diurnal behaviour in PM mass concentration was observed at both urban sites, which peaks during the morning and evening Nairobi rush hours; this was consistent with the high roadside increment indicating that vehicular traffic is a dominant source of PM in the city, accounting for approximately 48.1 %, 47.5 % and 57.2 % of the total PM loading in the PM10, PM2.5 and PM1 size ranges, respectively. Collocated meteorological measurements at the urban sites were collected, allowing for an understanding of the location of major sources of particulate matter at the two sites. The potential problems of using low-cost sensors for PM measurement without gravimetric calibration available at all sites are discussed. This study shows that calibrated low-cost sensors can be successfully used to measure air pollution in cities like Nairobi. It demonstrates that low-cost sensors could be used to create an affordable and reliable network to monitor air quality in cities.

19 September 2014 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
SGS. M. Gaita
S. M. Gaita
JBJohan Boman
Johan Boman
MGMichael James Gatari Gichuru
Michael James Gatari Gichuru
JPJ. B. C. Pettersson
J. B. C. Pettersson
SJSara Janhäll
Sara Janhäll
Sources of airborne particulate matter and their seasonal variation in urban areas in Sub-Saharan Africa are poorly understood due to lack of long-term measurement data. In view of this, filter samples of airborne particulate matter (particle diameter ≤2.5 μm, PM2.5) were collected between May 2008 and April 2010 at two sites (urban background site and suburban site) within the Nairobi metropolitan area. A total of 780 samples were collected and analyzed for particulate mass, black carbon (BC) and 13 trace elements. The average PM2.5 concentration at the urban background site was 21±9.5 μg m−3, whereas the concentration at the suburban site was 13±7.3 μg m−3. The daily PM2.5 concentrations exceeded 25 μg m−3 (the World Health Organization 24 h guideline value) on 29% of the days at the urban background site and 7% of the days at the suburban site. At both sites, BC, Fe, S and Cl accounted for approximately 80% of all detected elements. Positive matrix factorization analysis identified five source factors that contribute to PM2.5 in Nairobi, namely traffic, mineral dust, industry, combustion and a mixed factor (composed of biomass burning, secondary aerosol and aged sea salt). Mineral dust and traffic factors were related to approximately 74% of PM2.5. The identified source factors exhibited seasonal variation, apart from the traffic factor, which was prominently consistent throughout the sampling period. Weekly variations were observed in all factors, with weekdays having higher concentrations than weekends. The results provide information that can be exploited for policy formulation and mitigation strategies to control air pollution in Sub-Saharan African cities.

1 June 2015 in Atmospheric Environment
Verified
Journal Article
Closed access
NNNicole S. Ngo
Nicole S. Ngo
MGMichael James Gatari Gichuru
Michael James Gatari Gichuru
BYBeizhan Yan
Beizhan Yan
SCSteven N. Chillrud
Steven N. Chillrud
KBKheira Bouhamam
Kheira Bouhamam
PKPatrick Kinney
Patrick Kinney

1 April 2022 in Communications Earth & Environment
Verified
Journal Article
Open access
PDF file
LKLeonard Kirago
Leonard Kirago
MGMichael James Gatari Gichuru
Michael James Gatari Gichuru
ÖGÖrjan Gustafsson
Örjan Gustafsson
AAAugust Andersson
August Andersson
Rapid urbanization and population growth drives increased air pollution across Sub-Saharan Africa with serious implications for human health, yet pollutant sources are poorly constrained. Here, we analyse fine particulate aerosol concentrations and radiocarbon composition of black carbon over a full annual cycle in Nairobi, Kenya. We find that particle concentrations exceed the World Health Organisation’s recommended safe limit throughout the year, with little seasonal variability in particle concentration or composition. Organics (49 ± 7%) and water-soluble inorganic ions, dominated by sulfates (13 ± 5%), constitute the largest contributors to the particle loadings. Unlike large cities on other continents, the fraction of black carbon in particles is high (15 ± 4%) suggesting black carbon is a prominent air pollutant in Nairobi. Radiocarbon-based source quantification indicates that fossil fuel combustion emissions are a dominant source of black carbon throughout the year (85 ± 3%). Taken together, this indicates that black carbon emissions from traffic are a key stressor for air quality in Nairobi.