Minjae Kim

Mr. Minjae Kim


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 July 2015 in Sensors
Verified
Journal Article
Open access
PDF file
MKMinjae Kim
Minjae Kim
TKTaewan Kim
Taewan Kim
DKDong Sung Kim
Dong Sung Kim
WCWan Kyun Chung
Wan Kyun Chung
Surface electromyography is widely used in many fields to infer human intention. However, conventional electrodes are not appropriate for long-term measurements and are easily influenced by the environment, so the range of applications of sEMG is limited. In this paper, we propose a flexible band-integrated, curved microneedle array electrode for robust long-term measurements, high selectivity, and easy applicability. Signal quality, in terms of long-term usability and sensitivity to perspiration, was investigated. Its motion-discriminating performance was also evaluated. The results show that the proposed electrode is robust to perspiration and can maintain a high-quality measuring ability for over 8 h. The proposed electrode also has high selectivity for motion compared with a commercial wet electrode and dry electrode.

30 December 2017 in Sensors
Verified
Journal Article
Open access
PDF file
MKMinjae Kim
Minjae Kim
GGGangyong Gu
Gangyong Gu
KCKyoung Je Cha
Kyoung Je Cha
DKDong Sung Kim
Dong Sung Kim
WCWan Kyun Chung
Wan Kyun Chung
Surface electromyography (sEMG) signals reflect muscle contraction and hence, can provide information regarding a user’s movement intention. High-density sEMG systems have been proposed to measure muscle activity in small areas and to estimate complex motion using spatial patterns. However, conventional systems based on wet electrodes have several limitations. For example, the electrolyte enclosed in wet electrodes restricts spatial resolution, and these conventional bulky systems limit natural movements. In this paper, a microneedle-based high-density electrode array on a circuit integrated flexible substrate for sEMG is proposed. Microneedles allow for high spatial resolution without requiring conductive substances, and flexible substrates guarantee stable skin–electrode contact. Moreover, a compact signal processing system is integrated with the electrode array. Therefore, sEMG measurements are comfortable to the user and do not interfere with the movement. The system performance was demonstrated by testing its operation and estimating motion using a Gaussian mixture model-based, simplified 2D spatial pattern.