This work addresses the design and numerical characterization of a new exoskeleton solution for human leg motion assistance and rehabilitation. The exoskeleton solution is anthropomorphic, simple, low cost and easy to adapt on the human subject. The design aspect concerns the exoskeleton mechatronic structure, achieved in SolidWorks virtual environment. Numerical simulation is performed in MSC.ADAMS simulation environment. Obtained results for the exoskeleton computed motion are compared with those obtained from experimental walking of healthy subject. The prototype feasibility is studied both for design and operation aspect.

24 October 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Doina PislaDoina Pisla
Doina Pisla
Daniela TarnitaDaniela Tarnita
Daniela Tarnita
PTPaul Tucan
Paul Tucan
NTNicoleta Tohanean
Nicoleta Tohanean
Calin VaidaCalin Vaida
Calin Vaida
NPNicolae Plitea
Nicolae Plitea
Robots for rehabilitation tasks require a high degree of safety for the interaction with both the patients and for the operators. In particular, high safety is a stable and intuitive control of the moving elements of the system combined with an external system of sensors able to monitor the position of every aspect of the rehabilitation system (operator, robot, and patient) and overcome in a certain measure all the events that may occur during the robotic rehabilitation procedure. This paper presents the development of an internal torque monitoring system for ASPIRE. This is a parallel robot designed for shoulder rehabilitation, which enables the use of strategies towards developing a HRI (human–robot interaction) system for the therapy. A complete analysis regarding the components of the robotic system is carried out with the purpose of determining the dynamic behavior of the system. Next, the proposed torque monitoring system is developed with respect to the previously obtained data. Several experimental tests are performed using healthy subjects being equipped with a series of biomedical sensors with the purpose of validating the proposed torque monitoring strategy and, at the same time, to satisfy the degree of safety that is requested by the medical procedure.


13 December 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Ionut Daniel GeoneaIonut Daniel Geonea
Ionut Daniel Geonea
Daniela TarnitaDaniela Tarnita
Daniela Tarnita
Doina PislaDoina Pisla
Doina Pisla
Giuseppe CarboneGiuseppe Carbone
Giuseppe Carbone
BABolcu Alexandru
Bolcu Alexandru
Daniela TarnitaDaniela Tarnita
Daniela Tarnita
This paper presents studies on the dynamic analysis of the ASPIRE robot, which was designed for the medical recovery of brachial monoparesis. It starts from the virtual model of the existing version of the ASPIRE robot, which is analysed kinematically and dynamically by numerical simulations using the MSC.ADAMS software. For this purpose, this paper presents theoretical aspects regarding the kinematics and dynamics of the markers attached to the flexible bodies built in a specifically developed MSC.ADAMS model. Three simulation hypotheses are considered: (a) rigid kinematic elements without friction in couplings, (b) rigid kinematic elements with friction in couplings, and (c) kinematic elements as deformable solids with friction in couplings. Experimental results obtained by using the physical prototype of ASPIRE are presented. Results such as the connecting forces in the kinematic joints and the torques necessary to operate the ASPIRE robot modules have been obtained by dynamic simulation in MSC.ADAMS and compared with those determined experimentally. The comparison shows that the allure of the variation curve of the moment obtained by simulation is similar to that obtained experimentally. The difference between the maximum experimental value and that obtained by simulation is less than 1%. A finite element analysis (FEA) of the structurally optimized flexion/extension robot module is performed. The results demonstrate the operational safety of the ASPIRE robot, which is structurally capable of supporting the stresses to which it is subjected.

22 May 2019 in Journal of Bionic Engineering
Verified
Journal Article
Closed access
PDF file
Daniela TarnitaDaniela Tarnita
Daniela Tarnita
DPDoina Pisla
Doina Pisla
Ionut Daniel GeoneaIonut Daniel Geonea
Ionut Daniel Geonea
CVCalin Vaida
Calin Vaida
MCMarius Catana
Marius Catana
DTDanut Nicolae Tarnita
Danut Nicolae Tarnita

29 November 2016
Verified
Book Chapter
Closed access
PDF file
Ionut Daniel GeoneaIonut Daniel Geonea
Ionut Daniel Geonea
APAlin Petcu
Alin Petcu
Daniela TarnitaDaniela Tarnita
Daniela Tarnita