This paper presents the design of an innovative robotic system for lower limb post-stroke rehabilitation of bed confined patients during the acute stage of the treatment. To establish the particularities of each targeted joint motion, experimental measurements are performed on healthy subjects. The acquired data is used to determine the operational workspace, namely the limits of the anatomic joints motion for the lower limb. Based on the prescribed operational workspace, an innovative parallel robotic architecture is designed for achieving the rehabilitation of the lower limb. A detailed kinematic modelling and analysis is carried out to demonstrate the robot capability to safely achieve the required motions. The design of the robotic rehabilitation device is discussed in detail alongside with numerical simulations for validating its performance while performing medically relevant rehabilitation motions.
The aim of this work is to study the physical-chemical, mechanical, and biocompatible properties of hydroxyapatite obtained by hydrothermal synthesis, at relatively low temperatures and high pressures, starting from natural sources (Rapana whelk shells), knowing that these properties influence the behavior of nanostructured materials in cells or tissues. Thus, hydroxyapatite nanopowders were characterized by chemical analysis, Fourier-transform infrared spectroscopy (FT-IR), dynamic light scattering (DLS), scanning electron microscopy (SEM), and X-ray diffraction (XRD). In vitro studies on osteoblast cell lines (cytotoxicity and cell proliferation), as well as preliminary mechanical tests, have been performed. The results showed that the obtained powders have a crystallite size below 50 nm and particle size less than 100 nm, demonstrating that hydrothermal synthesis led to hydroxyapatite nanocrystalline powders, with a Ca:P ratio close to the stoichiometric ratio and a controlled morphology (spherical particle aggregates). The tensile strength of HAp samples sintered at 1100 °C/90 min varies between 37.6–39.1 N/mm2. HAp samples sintered at 1300 °C/120 min provide better results for the investigated mechanical properties. The coefficient of friction has an appropriate value for biomechanical applications. The results of cell viability showed that the cytotoxic effect is low for all tested samples. Better cell proliferation is observed for osteoblasts grown on square samples.
This work addresses the design and numerical characterization of a new exoskeleton solution for human leg motion assistance and rehabilitation. The exoskeleton solution is anthropomorphic, simple, low cost and easy to adapt on the human subject. The design aspect concerns the exoskeleton mechatronic structure, achieved in SolidWorks virtual environment. Numerical simulation is performed in MSC.ADAMS simulation environment. Obtained results for the exoskeleton computed motion are compared with those obtained from experimental walking of healthy subject. The prototype feasibility is studied both for design and operation aspect.
Robots for rehabilitation tasks require a high degree of safety for the interaction with both the patients and for the operators. In particular, high safety is a stable and intuitive control of the moving elements of the system combined with an external system of sensors able to monitor the position of every aspect of the rehabilitation system (operator, robot, and patient) and overcome in a certain measure all the events that may occur during the robotic rehabilitation procedure. This paper presents the development of an internal torque monitoring system for ASPIRE. This is a parallel robot designed for shoulder rehabilitation, which enables the use of strategies towards developing a HRI (human–robot interaction) system for the therapy. A complete analysis regarding the components of the robotic system is carried out with the purpose of determining the dynamic behavior of the system. Next, the proposed torque monitoring system is developed with respect to the previously obtained data. Several experimental tests are performed using healthy subjects being equipped with a series of biomedical sensors with the purpose of validating the proposed torque monitoring strategy and, at the same time, to satisfy the degree of safety that is requested by the medical procedure.