Background: Lysosomal storage disorders (LSDs) comprise more than 40 genetic diseases that result in the accumulation of products that would normally be degraded by lysosomal enzymes. A tandem mass spectrometry (MS/MS)-based method is available for newborn screening for 5 LSDs, and many laboratories are initiating pilot studies to evaluate the incorporation of this method into their screening panels. We developed and evaluated dried blood spot (DBS) QC materials for LSDs and used the MS/MS method to investigate their suitability for LSD QC monitoring. Methods: We incubated 3.2-mm punches from DBS controls for 20–24 h with assay cocktails containing substrate and internal standard. Using MS/MS, we quantified the resulting product and internal standard. Samples were run in triplicate for 3 consecutive days, and results were reported as product-to-internal standard ratios and enzyme activity units (μmol/L/h). Results: Enzyme activity interday imprecision (CV) for the high, medium, and low series were 3.4%–14.3% for galactocerebroside α-galactosidase, 6.8%–24.6% for acid α-galactosidase A, 7.36%–22.1% for acid sphingomyelinase, 6.2%–26.2% for acid α-glucocerebrosidase, and 7.0%–24.8% for lysosomal acid α-glucosidase (n = 9). In addition, DBS stored at −20° and 4 °C showed minimal enzyme activity loss over a 187-d period. DBS stored at 37° and 45 °C had lower activity values over the 187-day evaluation time. Conclusions: Suitable QC materials for newborn screening of LSDs were developed for laboratories performing DBS LSD screening. Good material linearity was observed, with goodness-of-fit values of 0.953 and higher. The QC materials may be used by screening laboratories that perform LSD analysis by MS and/or more conventional fluorescence-based screening methods.
Dried blood spots (DBS) have been used in newborn screening (NBS) tests for over 50 years. The Newborn Screening Quality Assurance Program (NSQAP) at the Centers for Disease Control and Prevention (CDC) conducted studies to assess the individual impacts of hematocrit and total-spot volume on characteristics of DBS samples. Per-punch serum volumes decreased 27%, RBC volumes more than doubled, absorption times increased over 300%, and spot diameters decreased marginally between the hematocrits of 40% to 65%. Per-punch serum and RBC volumes decreased logarithmically with lowering total-spot volumes. Patient hematocrit is an uncontrollable variable and inevitably affects the resulting punch from a DBS sample. It may be possible, though, to identify samples that fall outside of an acceptable range by noting certain physical characteristics of the DBS.
Newborn screening is the largest population-based genetic screening effort in the United States. The detection of treatable, inherited congenital disorders is a major public health responsibility. The Centers for Disease Control and Prevention's (CDC's) Newborn Screening Quality Assurance Program helps newborn screening laboratories ensure that testing accurately detects these disorders, does not delay diagnosis, minimizes false-positive reports, and sustains high-quality performance. For over 30 years, the CDC's Newborn Screening Quality Assurance Program has performed this essential public health service, ensuring the quality and accuracy of screening tests for more than 4 million infants born each year in the United States and millions more worldwide. The Program has grown from 1 disorder in 1978 for 31 participants to more than 50 disorders for 459 participants in 2009. This report reviews the Program's milestones and services to the newborn screening community.