Elizabeth Hall

Ms. Elizabeth Hall


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
EHElizabeth Hall
Elizabeth Hall
SFSharon R. Flores
Sharon R. Flores
VJVictor De Jesus
Victor De Jesus
Dried blood spots (DBS) have been used in newborn screening (NBS) tests for over 50 years. The Newborn Screening Quality Assurance Program (NSQAP) at the Centers for Disease Control and Prevention (CDC) conducted studies to assess the individual impacts of hematocrit and total-spot volume on characteristics of DBS samples. Per-punch serum volumes decreased 27%, RBC volumes more than doubled, absorption times increased over 300%, and spot diameters decreased marginally between the hematocrits of 40% to 65%. Per-punch serum and RBC volumes decreased logarithmically with lowering total-spot volumes. Patient hematocrit is an uncontrollable variable and inevitably affects the resulting punch from a DBS sample. It may be possible, though, to identify samples that fall outside of an acceptable range by noting certain physical characteristics of the DBS.

Verified
Journal Article
Open access
PDF file
PDPaul Dantonio
Paul Dantonio
Norma TavakoliNorma Tavakoli
Norma Tavakoli
BMBrooke Migliore
Brooke Migliore
EHElizabeth Hall
Elizabeth Hall
TLTimothy Lim
Timothy Lim
RVRobert Vogt
Robert Vogt
Pilot studies to detect newborns with Duchenne Muscular Dystrophy (DMD) by newborn bloodspot screening (NBS) have been conducted under the New York State Newborn Screening Program (NYS) and are currently in progress as part of the Early Check Program at Research Triangle Institute (RTI) International. The Newborn Screening Quality Assurance Program (NSQAP) at the U.S. Centers for Disease Control and Prevention (CDC) produced a set of seven prototype dried blood spot (DBS) reference materials spiked with varying levels of creatine kinase MM isoform (CK-MM). These DBS were evaluated over a 3-week period by CDC, NYS, and RTI, all using the same CK-MM isoform-specific fluoroimmunoassay. Results from each laboratory were highly correlated with the relative proportion of CK-MM added to each of the six spiked pools. Based on reference ranges established by NYS and RTI for their pilot studies, these contrived DBS collectively spanned the CK-MM ranges found in typical newborns and the elevated ranges associated with DMD. This set allows quality assessment over the wide range of fluctuating CK-MM levels in typical and DMD-affected newborns.