Selenium (Se) contamination of public lands and water is a result of irrigated agriculture and mining activities in areas rich in Se geologic deposits. Pariette Draw is part of the northern Colorado Plateau and is an area of concern for Se contamination in the Pariette Wetlands. Pariette Wetlands, a wetland built in the 1970s to provide wildlife habitat, is distinguished by its arid climate and a short growing season of hot dry summers followed by cold winters with several months below freezing. An understanding of how Se is mobilized and removed within the wetland will provide management strategies that minimize and mitigate Se contamination and promote sustainable ecosystem services. The data collected in 2012 and 2014 was the first comprehensive spatial and temporal analysis of Se in all environmental compartments (bird eggs, macroinvertebrates, plants, sediments, and water) of an arid wetland ecosystem in the Colorado Plateau. Water, sediment, and plant tissue samples were collected and analyzed to determine Se’s spatial and temporal variation in Pariette Wetlands. Se concentrations in water, sediment, and plants were evenly distributed throughout wetlands. No significant differences were found in plant Se concentrations between samples collected in 2012 (447 ± 44 ug kg−1) or 2014 (541 ± 42 μg kg−1), indicating that plant Se did not vary temporally during sampling. Aquatic plant species (e.g., pondweed (Potamogeton filiformis), 743 ± 66 μg kg−1 and watermilfoil (Myriophyllum spicatum), 874 ± 122 μg kg−1) accumulated more Se than plant species growing at the edges of the ponds (e.g., hardstem bulrush (Schoenoplectus acutus), 368 ± 37 μg kg−1 and cattail (Typha), 420 ± 43 μg kg−1). Plant roots (1045 ± 110 μg kg−1) accumulated more Se than aboveground vegetation (flowers, 228 ± 17 μg kg−1 or stems, 224 ± 19 μg kg−1). Relative to Se retained by sediments (75%), plants were not an extensive reservoir of wetland Se (<5%) but still may pose a risk to animals feeding on plant tissue. Thus, phytoremediation of Se does not appear to be a viable tool for Se mitigation in wetlands of arid climates with a short growing season, such as those located in the Colorado Plateau.
During wintertime temperature inversion episodes, ozone in the Uinta Basin sometimes exceeds the standard of 70 ppb set by the US Environmental Protection Agency. Since ozone formation depends on sunlight, and less sunlight is available during winter, wintertime ozone can only form if snow cover and albedo are high. Researchers have encountered difficulties replicating high albedo values in 3-D weather and photochemical transport model simulations for winter episodes. In this study, a process to assimilate MODIS satellite data into WRF and CAMx models was developed, streamlined, and tested to demonstrate the impacts of data assimilation on the models’ performance. Improvements to the WRF simulation of surface albedo and snow cover were substantial. However, the impact of MODIS data assimilation on WRF performance for other meteorological quantities was minimal, and it had little impact on ozone concentrations in the CAMx photochemical transport model. The contrast between the data assimilation and reference cases was greater for a period with no new snow since albedo appears to decrease too rapidly in default WRF and CAMx configurations. Overall, the improvement from MODIS data assimilation had an observed enhancement in the spatial distribution and temporal evolution of surface characteristics on meteorological quantities and ozone production.
7 March 2025 in Journal of the Air & Waste Management Association
We measured organic compound emissions from a produced-water, evaporative disposal facility's oil-water separation vault in May 2022 and March-May 2023. Produced water is water pulled from the subsurface of a well along with the oil and natural gas; some produced water is disposed of by allowing it to evaporate from surface impoundments. The vault measured in this study separated residual oil from produced water before evaporative disposal. Because the vault's surface contained many potential small emission sources, we used a large plastic chamber to cover the entire vault and simultaneously capture all emissions. We also measured organic compounds in ambient air upwind and downwind of the vault and estimated emissions via a backward Lagrangian stochastic model (Windtrax). The total non-methane organic compound (TNMOC) emission rate from the vault ranged from 0.27 to 3.05 kg/h, averaging 1.99 kg/h in 2022 and 0.49 kg/h in 2023. The average TNMOC emission rate determined by the bLS method was 48% higher than the emission rate determined by the chamber method in 2023 (average of 0.73 kg/h). Still, the range of the chamber results fell within the range of TNMOC emissions from the model. Methanol emissions were much higher than the bLS method, averaging 85.3 g/hr, but were highly variable. We surmise that the water condensation on the chamber retained methanol and biased the results low. The extrapolated annual average emissions of methane, TNMOC, and methanol from the vault were 0.1, 15.5, and 1.4 U.S. tons/yr, respectively, within the range of emissions from uncontrolled oil storage tanks. The extrapolation considers bias in the chamber method and differences across the two years of measurements.Implications Statement The findings from our study indicate that emissions of non-methane organic compounds (TNMOC) from the oil-water separation vault at the produced-water evaporative disposal facility exhibit significant variability between years, with a notable decline in average emissiosns from 2022 to 2023. The higher emission rates recorded using the backward Lagrangian stochastic (bLS) model compared to the chamber method suggest that further investigation into measurement techniques is warranted to ensure accurate assessments of emissions. Additionally, the substantial variability in methanol emissions highlights the need for more controlled conditions during sampling to avoid potential biases. Overall, these results imply that while emissions from the vault are within the range of those from uncontrolled oil storage tanks, there is an ongoing necessity for improved monitoring and regulatory practices to mitigate environmental impacts associated with produced water disposal.
This study investigates emissions total organic compound (TOC) of methane and speciated total non-methane organic compounds (TNMOC) from key components at oil well pads in Duchesne County, Utah, focusing on liquid storage tanks, separator equipment, and wellhead systems. Using a custom-built high-flow sampling system, we quantified emissions from these components and compared them to regulatory data. Measured TOC emissions from oil tanks ranged from 10 to 1,480 g h−1 (median 150 g h−1), exceeding emissions from wellheads (15–500 g h−1; median 120 g h−1) and water tanks (3.9–50 g h−1; median 30 g h−1). Thief hatches and pressure relief valves were the primary emission points on tanks, even those routed to combustors. Methane emissions from oil tanks were higher than regulatory tank emission estimates, and oil tank emissions were also the most reactive (i.e., highest ozone-forming potential). Water tank emissions were less reactive, while wellhead emissions were richer in NMOCs relative to other non-tank sources. These results provide critical quantitative data to improve air quality assessments of oil and gas infrastructure.