Young-Sung Kim

Young-Sung Kim


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2010 in Journal of Periodontal & Implant Science
Verified
Journal Article
Open access
PDF file
HKHak-Sung Kim
Hak-Sung Kim
KKKyoung-Hwa Kim
Kyoung-Hwa Kim
SKSu-Hwan Kim
Su-Hwan Kim
YKYoung-Sung Kim
Young-Sung Kim
KKKi-Tae Koo
Ki-Tae Koo
YLYong-Moo Lee
Yong-Moo Lee
Kim HS, et al. J Periodontal Implant Sci. 2010 Dec;40(6):265-270. http://dx.doi.org/10.5051/jpis.2010.40.6.265

1 January 2011 in Journal of Periodontal & Implant Science
Verified
Journal Article
Open access
PDF file
SKSu-Hwan Kim
Su-Hwan Kim
YKYoung-Sung Kim
Young-Sung Kim
SLSu-Yeon Lee
Su-Yeon Lee
KKKyoung-Hwa Kim
Kyoung-Hwa Kim
YLYong-Moo Lee
Yong-Moo Lee
YLYoung-Kyoo Lee
Young-Kyoo Lee
Kim SH, et al. J Periodontal Implant Sci. 2011 Aug;41(4):192-200. http://dx.doi.org/10.5051/jpis.2011.41.4.192

3 September 2014 in Acta Odontologica Scandinavica
Verified
Journal Article
Closed access
PDF file
YKYoung-Sung Kim
Young-Sung Kim
SSSeung-Yun Shin
Seung-Yun Shin
SMSeung-Kyun Moon
Seung-Kyun Moon
SYSeung-Min Yang
Seung-Min Yang
Objectives. To reveal the suitable surface condition of an implant abutment for fibroblast attachment, the correlation between the surface characteristics of various materials and the human gingival fibroblast (HGF-1) attachment to the surfaces were analyzed. Methods. Six kinds of surfaces comprised of machined titanium alloy (SM), machined Co-Cr-Mo alloy (CCM), titanium nitride coated titanium alloy (TiN), anodized titanium alloy (AO), composite resin coating on titanium alloy (R) and zirconia (Zr) were used. The measured surface parameters were Sa, Sq, Sz, Sdr, Sdq, Sal, Str and water contact angle (WCA). The HGF-1 cell attachment was investigated and the correlations were analyzed using a multiple regression analysis. Results. The HGF-1 cell attachment was greater in the SM, TiN and Zr groups than the other groups and smallest in the CCM group (p = 0.0096). From the multiple regression analysis, the HGF-1 cell attachment was significantly correlated with Sdr, Sdq and WCA. When the R group was excluded, only WCA showed significant correlation with the fibroblast attachment. Conclusions. Within the limitations of this study, the cell attachment of human gingival fibroblasts was correlated with WCA, developed interfacial area ratio and surface slope. When the surfaces with Sa values of ∼ 0.2 μm or less were concerned, only WCA showed a correlation in a third order manner.

16 May 2013 in Journal of Oral Rehabilitation
Verified
Journal Article
Closed access
PDF file
HCH.‐S. Cha
H.‐S. Cha
YKYoung-Sung Kim
Young-Sung Kim
JJJ.‐H. Jeon
J.‐H. Jeon
JLJoo-Hee Lee
Joo-Hee Lee

1 July 2014 in The International Journal of Oral and Maxillofacial Implants
Verified
Journal Article
Closed access
YKYoung-Sung Kim
Young-Sung Kim
YKYoungkyung Ko
Youngkyung Ko
SKSeung-Beom Kye
Seung-Beom Kye
SYSeung-Min Yang
Seung-Min Yang
Young-Sung Kim, DDS, MSD, PhD/Youngkyung Ko, DDS, MSD, PhD/Seung-Beom Kye, DDS, MSD, PhD/Seung-Min Yang, DDS, MSD, PhD: Purpose: An implant abutment should be soft tissue?compatible and resistant to plaque accumulation, and it is preferable for an implant abutment to have color harmony with the surrounding tissues. This study aimed to compare the in vitro fibroblast cell attachment and proliferation on several abutment materials of different colors. Materials and Methods: A total of 240 specimens in 6 experimental groups were used: titanium alloy (SM [smooth machined]; gray), cobalt-chrome-molybdenum alloy (CCM; gray), titanium nitride?coated titanium (TiN; yellow), anodic-oxidized titanium (AO; dark pink), composite resin?coated titanium (R; white), and zirconia (Zr; white). The culture plate surface was employed as a control (C). The surface roughness (Sa), developed interfacial area ratio (Sdr), and water contact angle (WCA) were measured. The human gingival fibroblast (HGF-1) attachment and proliferation at the third and seventh days were observed. Results: Sa values of all experimental groups were < 0.5 μm. Sdr values were between 5% and 8%, except for the Zr group (0.06%). WCA of all groups was greater than 40 degrees. More HGF-1 cells attached on the surfaces of the SM, TiN, and Zr groups than the C group, and the least number of cells were observed on the CCM group (P < .001). On the third day of proliferation, the C group showed significantly greater proliferation than all experimental groups (P < .001). On the seventh day of proliferation, the TiN, AO, Zr, and C groups exhibited twice the number of cells compared to the rest of the groups (P < .001). Conclusion: Within the limitations of this study, zirconia abutments would be the best choice in the anterior region. Titanium nitride?coated titanium alloy abutments or anodic-oxidized titanium alloy abutments might also be good choices in areas of esthetic challenge or under high occlusal loads.

1 January 2012 in Journal of Periodontal & Implant Science
Verified
Journal Article
Open access
PDF file
YKYoung-Sung Kim
Young-Sung Kim
SKSu-Hwan Kim
Su-Hwan Kim
KKKyoung-Hwa Kim
Kyoung-Hwa Kim
MJMin-Ju Jhin
Min-Ju Jhin
WKWon-Kyung Kim
Won-Kyung Kim
YLYong-Moo Lee
Yong-Moo Lee
Kim YS, et al. J Periodontal Implant Sci. 2012 Dec;42(6):204-211. http://dx.doi.org/10.5051/jpis.2012.42.6.204