Anggito P. Tetuko

Dr. Anggito P. Tetuko


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2016 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
ATAnggito P. Tetuko
Anggito P. Tetuko
Bahman ShabaniBahman Shabani
Bahman Shabani
JAJohn Andrews
John Andrews

1 September 2018 in Journal of Power Sources
Verified
Journal Article
Closed access
ATAnggito P. Tetuko
Anggito P. Tetuko
Bahman ShabaniBahman Shabani
Bahman Shabani
ROReza Omrani
Reza Omrani
BPBiddyut Paul
Biddyut Paul
JAJohn Andrews
John Andrews

1 December 2019 in Materials Letters
Verified
Journal Article
Closed access
MRMartha Rianna
Martha Rianna
MSMarhaposan Situmorang
Marhaposan Situmorang
CKCandra Kurniawan
Candra Kurniawan
ATAnggito P. Tetuko
Anggito P. Tetuko
ESEko Arief Setiadi
Eko Arief Setiadi
PSPerdamean Sebayang
Perdamean Sebayang

1 November 2019 in Journal of Molecular Liquids
Verified
Journal Article
Closed access
IDIndri Dayana
Indri Dayana
TSTimbangen Sembiring
Timbangen Sembiring
ATAnggito P. Tetuko
Anggito P. Tetuko
KSKurnia Sembiring
Kurnia Sembiring
NMNurul Maulida
Nurul Maulida
PSPerdamean Sebayang
Perdamean Sebayang

13 April 2018 in Energies
Verified
Journal Article
Open access
PDF file
ATAnggito P. Tetuko
Anggito P. Tetuko
Bahman ShabaniBahman Shabani
Bahman Shabani
JAJohn Andrews
John Andrews
This paper reports on an experimental investigation of a passive thermal coupling arrangement between a Proton Exchange Membrane (PEM) fuel cell and a Metal Hydride (MH) hydrogen storage canister using heat pipes for enhancing the release rate of hydrogen. The performance of this arrangement was measured by inserting the evaporator sections of the heat pipes into an aluminum plate mimicking one out of five cooling plates of a 500-W fuel cell (that is a 100 W section of the stack). Thermal pads were attached on both sides of the plate to represent the fuel cell heat to be supplied to a 660-sl MH canister. The results showed that the operating temperature of the fuel cell can be maintained in the desired range of 60–80 °C. A complementary experimental study was also conducted on an 800-sl MH canister supplying hydrogen to a 130-W fuel cell stack (a slightly scaled-up setup compared to the first experiment). The study confirmed the findings of an earlier theoretical study by the authors that by supplying about 20% of the total cooling load of the stack to a MH canister, its maximum sustainable hydrogen supply rate increased by 70%, allowing for continuous operation of the stack at its rated power.

1 March 2019 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
MRMartha Rianna
Martha Rianna
TSTimbangen Sembiring
Timbangen Sembiring
MSMarhaposan Situmorang
Marhaposan Situmorang
CKCandra Kurniawan
Candra Kurniawan
ATAnggito P. Tetuko
Anggito P. Tetuko
PSPerdamean Sebayang
Perdamean Sebayang