Kuo-Chih Su

Dr. Kuo-Chih Su

Department of Medical Research, Taichung Veterans General Hospital
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 May 2019 in Applied Bionics and Biomechanics
Verified
Journal Article
Open access
PDF file
WHWeien Hsu
Weien Hsu
Kuo-Chih SuKuo-Chih Su
Kuo-Chih Su
KCKun-Hui Chen
Kun-Hui Chen
CPChien-Chou Pan
Chien-Chou Pan
WLWen-Hsien Lu
Wen-Hsien Lu
CLCheng-Hung Lee
Cheng-Hung Lee
For compression fracture, vertebral body height loss (VBHL) and kyphotic angle (KA) are two important imaging parameters for determining the prognosis and appropriate treatment. This study used previous measurement methods to assess the degree of VBHL and KA, compare and examine differences between various measurement methods, and examine the correlation between relevant measurement parameters and intravertebral cleft (IVC) in the vertebral body. The radiographic images (lateral view of the T-L spine) of 18 patients with a single-level vertebral compression fracture were reviewed. We measured 9 characteristic lengths and angles on plain radiographs, including anterior vertebral height (AVH) and AVH of the adjacent upper and lower levels, middle vertebral height (MVH) and MVH of the adjacent upper and lower levels, posterior vertebral height (PVH), and vertebral body width, and assessed 6 parameters, including vertebral compression ratio (VBCR), percentage of anterior height compression (PAHC), percentage of middle height compression (PMHC), kyphotic angle (KA), calculated kyphotic angle (CKA), and IVC. The results showed that VBCR is a simple and rapid method of VBHL assessment, but it may result in an underestimation of the degree of VBHL compared to PAHC. WhenPMHC<40%orkyphotic angle>15°, the probability of IVC occurring on the vertebral body was higher which means the higher risk of vertebral body instability. The results of this study could provide a reference for surgeons when using imaging modalities to assess the degree of vertebral body collapse.

27 January 2016 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
CLCheng‐Hung Lee
Cheng‐Hung Lee
CSCheng‐Min Shih
Cheng‐Min Shih
KHKui-chou Huang
Kui-chou Huang
KCKun‐Hui Chen
Kun‐Hui Chen
LHLi‐Kun Hung
Li‐Kun Hung
Kuo-Chih SuKuo-Chih Su
Kuo-Chih Su

17 July 2015 in International Orthopaedics
Verified
Journal Article
Closed access
PDF file
CSCheng-Min Shih
Cheng-Min Shih
KHKui-Chou Huang
Kui-Chou Huang
CPChien-Chou Pan
Chien-Chou Pan
CLCheng-Hung Lee
Cheng-Hung Lee
Kuo-Chih SuKuo-Chih Su
Kuo-Chih Su

23 August 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PLPei-Ju Lin
Pei-Ju Lin
Kuo-Chih SuKuo-Chih Su
Kuo-Chih Su
A dental implant is currently the most commonly used treatment for patients with lost teeth. There is no biomechanical reference available to study the effect of different occlusion conditions on dental implants with different positions. Therefore, the aim of this study was to conduct a biomechanical analysis of the impact of four common occlusion conditions on the different positions of dental implants using the finite element method. We built a finite element model that included the entire mandible and implanted seven dental implant fixtures. We also applied external force to the position of muscles on the mandible of the superficial masseter, deep masseter, medial pterygoid, anterior temporalis, middle temporalis, and posterior temporalis to simulate the four clenching tasks, namely the incisal clench (INC), intercuspal position (ICP), right unilateral molar clench (RMOL), and right group function (RGF). The main indicators measured in this study were the reaction force on the temporomandibular joint (TMJ) and the fixed top end of the abutment in the dental implant system, and the stress on the mandible and dental implant systems. The results of the study showed that under the occlusion conditions of RMOL, the dental implant system (113.99 MPa) and the entire mandible (46.036 MPa) experienced significantly higher stress, and the reaction force on the fixed-top end of the abutment in the dental implant system (261.09 N) were also stronger. Under the occlusion of ICP, there was a greater reaction force (365.8 N) on the temporomandibular joint. In addition, it was found that the reaction force on the posterior region (26.968 N to 261.09 N) was not necessarily greater than that on the anterior region (28.819 N to 70.431 N). This information can help clinicians and dental implant researchers understand the impact of different chewing forces on the dental implant system at different positions after the implantation.

24 April 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HHHeng-Li Huang
Heng-Li Huang
MTMing-Tzu Tsai
Ming-Tzu Tsai
SYShih-Guang Yang
Shih-Guang Yang
Kuo-Chih SuKuo-Chih Su
Kuo-Chih Su
YSYen-Wen Shen
Yen-Wen Shen
JHJui-Ting Hsu
Jui-Ting Hsu
We used the finite-element method (FEM) to investigate the effects of jawbone model integrity and the material properties of the periodontal ligament (PDL) on orthodontic tooth movement. Medical imaging software and computer-aided design software were used to create finite-element models of a partial and complete mandibles based on dental cone beam computed tomography images of the human skull. Additionally, we exerted an orthodontic force on the canine crown in the direction of an orthodontic miniscrew under a lower molar root to compare the von Mises strain on the canine PDL in three models: a partial mandible model under orthodontic force (Model 1), a complete mandible model under orthodontic force (Model 2), and a complete mandible model under orthodontic force with clench occlusion in the intercuspal position (ICP; Model 3). Additionally, in the complete mandible model under orthodontic force with ICP occlusion, we analyzed the effects of a PDL with a low (Model 4), moderate (Model 5), and high (Model 6) linear elastic modulus and a PDL a bilinear elastic modulus (Model 7). The simulation results for mandible integrity indicated that the maximum von Mises strains on the canine PDL for Models 1, 2, and 3 were 0.461, 0.394, and 1.811, respectively. Moreover, for the models with different PDL material properties, the maximum von Mises strains on the canine PDLs for Models 4, 5, 6, and 7 were 6.047, 2.594, 0.887, and 1.811, respectively. When the FEM was used to evaluate tooth movement caused by orthodontic force, the transformation of a complete mandible model into a partial mandible model or alteration of the elastic modulus of the PDL influenced the biomechanical responses of the PDL. Additionally, the incorporation of daily ICP occlusion resulted in a larger effect.

21 October 2021 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
CHChao-Min Huang
Chao-Min Huang
MCMan-Yee Chan
Man-Yee Chan
JHJui-Ting Hsu
Jui-Ting Hsu
Kuo-Chih SuKuo-Chih Su
Kuo-Chih Su
Background: Many types of titanium plates were used to treat subcondylar fracture clinically. However, the efficacy of fixation in different implant positions and lengths of the bone plate has not been thoroughly investigated. Therefore, the primary purpose of this study was to use finite element analysis (FEA) to analyze the biomechanical effects of subcondylar fracture fixation with miniplates at different positions and lengths so that clinicians were able to find a better strategy of fixation to improve the efficacy and outcome of treatment. Methods: The CAD software was used to combine the mandible, miniplate, and screw to create seven different FEA computer models. These models with subcondylar fracture were fixed with miniplates at different positions and of different lengths. The right unilateral molar clench occlusal mode was applied. The observational indicators were the reaction force at the temporomandibular joint, von Mises stress of the mandibular bone, miniplate and screw, and the sliding distance on the oblique surface of the fracture site at the mandibular condyle. Results: The results showed the efficacy of fixation was better when two miniplates were used comparing to only one miniplates. Moreover, using longer miniplates for fixation had better results than the short one. Furthermore, fixing miniplates at the posterior portion of subcondylar region would have a better fixation efficacy and less sliding distance (5.46–5.76 μm) than fixing at the anterolateral surface of subcondylar region (6.10–7.00 μm). Conclusion: Miniplate fixation, which was placed closer to the posterior margin, could effectively reduce the amount of sliding distance in the fracture site, thereby achieving greater stability. Furthermore, fixation efficiency was improved when an additional miniplate was placed at the anterior margin. Our study suggested that the placement of miniplates at the posterior surface and the additional plate could effectively improve stability.