For compression fracture, vertebral body height loss (VBHL) and kyphotic angle (KA) are two important imaging parameters for determining the prognosis and appropriate treatment. This study used previous measurement methods to assess the degree of VBHL and KA, compare and examine differences between various measurement methods, and examine the correlation between relevant measurement parameters and intravertebral cleft (IVC) in the vertebral body. The radiographic images (lateral view of the T-L spine) of 18 patients with a single-level vertebral compression fracture were reviewed. We measured 9 characteristic lengths and angles on plain radiographs, including anterior vertebral height (AVH) and AVH of the adjacent upper and lower levels, middle vertebral height (MVH) and MVH of the adjacent upper and lower levels, posterior vertebral height (PVH), and vertebral body width, and assessed 6 parameters, including vertebral compression ratio (VBCR), percentage of anterior height compression (PAHC), percentage of middle height compression (PMHC), kyphotic angle (KA), calculated kyphotic angle (CKA), and IVC. The results showed that VBCR is a simple and rapid method of VBHL assessment, but it may result in an underestimation of the degree of VBHL compared to PAHC. Whenor, the probability of IVC occurring on the vertebral body was higher which means the higher risk of vertebral body instability. The results of this study could provide a reference for surgeons when using imaging modalities to assess the degree of vertebral body collapse.
Robot-assisted pedicle screw placement for spine surgery has become popular in recent years. This study compares clinical, radiographic outcomes and the screw loosening rate between robot-assisted and fluoroscopy-guided pedicle screw placement in patients who underwent transforaminal lumbar interbody fusion (TLIF). We retrospectively examined 108 patients with the degenerative lumbar disease who underwent TLIF. According to whether the robotic system was used, patients were assigned to either the robot-assisted (Ro TLIF, n = 29) or fluoroscopy-guided TLIF (FG TLIF, n = 79) group. Radiographic parameters and patient-reported outcomes, including leg and back pain visual analog scale (VAS) and Oswestry Disability Index (ODI), were assessed. Loosening signs were noted in 48 out of 552 pedicle screws. The screw loosening rate was higher in the FG TLIF (10.2%) than Ro TLIF group (4.3%). A significant correlation was found between screw loosening and age, the number of level(s) fused, and the ratio of the average distance from the pedicle screw to the upper endplate to vertebral body height. VAS-leg, VAS-back, and ODI showed significant improvements in both groups postoperatively (all p < 0.05). These results indicated that robot-assisted pedicle screw placement in TLIF had a lower screw loosening rate and similar patient-reported outcomes compared with the fluoroscopy-guided technique.
Oblique lumbar interbody fusion (OLIF) is a popular technique for the treatment of degenerative lumbar spinal disease. There are no clear guidelines on whether direct posterior decompression (PD) is necessary after OLIF. The purpose of this study was to analyze the effect of the indirect decompression obtained from OLIF in patients with lumbar foraminal stenosis. We retrospectively reviewed 33 patients who underwent OLIF surgery for degenerative lumbar spinal disease between 1 January 2018, and 30 June 2019. The inclusion criteria included patients who were diagnosed with lumbar foraminal stenosis by preoperative MRI. The exclusion criteria included the presence of central canal stenosis, spinal infection, vertebral fractures, and spinal malignancies. The clinical results, evaluated using the visual analogue scale of back pain (VAS-Back), VAS of leg pain (VAS-Leg), and Oswestry disability index (ODI), were recorded. The radiologic parameters were also measured. The VAS-Back, VAS-Leg, and ODI showed significant improvement in both the PD and non-posterior decompression (Non-PD) groups postoperatively (all, p < 0.05). Patients in the Non-PD group showed better results than those in the PD group in the VAS-Back at 12- and 24 months postoperatively (0.00 vs. 3.00 postoperatively at 12 months, p = 0.030; 0.00 vs. 4.00 postoperatively at 24 months, p = 0.009). In addition, the ODI at 24 months postoperatively showed better improvement in the Non-PD group (8.89 vs. 24.44, p = 0.038). The disc height in both the PD and the Non-PD groups increased significantly postoperatively (all, p < 0.05), but the restoration of foraminal height was significantly different only in the Non-PD group. There was no statistically significant difference in cage position, cage subsidence, fusion grade, or screw loosening between the PD and the Non-PD groups. Indirect decompression via OLIF for lumbar foraminal stenosis showed favorable outcomes. The use of interbody cages and posterior instrumentation was sufficient for relieving symptoms in patients with lumbar foraminal stenosis. Additional direct posterior decompression may deteriorate results in the follow-up period.
Cortical bone trajectory (CBT) is increasingly used in spinal surgery. Although there are many biomechanical studies, the biomechanical effect of CBT in combination with traditional pedicle screws is not detailed. Therefore, the purpose of this study was to investigate the effects of the traditional pedicle screw and CBT screw implantation on the lumbar spine using finite element methods. Based on the combination of the traditional pedicle screw and the CBT system implanted into the lumbar spine, four finite element spinal lumbar models were established. The models were given four different load conditions (flexion, extension, lateral bending, and axial rotation), and the deformation and stress distribution on the finite element model were observed. The results show that there was no significant difference in the structural stability of the lumbar spine model between the traditional pedicle screw system and the CBT system. In addition, CBT may reduce stress on the endplate. Different movements performed by the model may have significant biomechanical effects on the spine and screw system. Clinical spinal surgeons may also consider using the CBT system in revision spinal surgery, which may contribute to smaller wounds.
With advancing stages of degeneration, denaturation and degradation of proteoglycans in the nucleus pulposus (NP) lead to tissue dehydration and signal intensity loss on T2-weighted MR images. Pfirrmann grading is widely used for grading degeneration of intervertebral discs (IVDs). The criterion to differentiate IVDs of Pfirrmann Grade I from the other grades is NP homogeneity. Pfirrmann grading is qualitative and its assessment may be subjective. Therefore, assessment of quantitative objective measures correlating with early disc degeneration may complement the grading. This study aimed to evaluate the applicability of the distance between the center weighted by signal intensity (weighted center) and the geometric center as a parameter of NP homogeneity. Other phenomena related to advancing stages of degeneration were also investigated. MR images of 65 asymptomatic volunteers with a total of 288 lumbar IVDs with clearly identifiable nucleus pulposus boundary (Pfirrmann Grade I, II and III) were included in this study. A custom-written program was developed to determine the IVD longitudinal axis, define the NP boundary, and to locate the coordinates of geometric and weighted NP centers on the mid-sagittal image of each studied IVD. The distances between the weighted and geometric centers on the longitudinal axis and the perpendicular axis of each IVD were calculated. The weighted center located posterior to the geometric center, which indicated the signal intensity was lower at the anterior portion of the NP, in 85.8% of studied IVDs. The distance between the weighted and geometric center on the longitudinal axis was significantly shorter in homogeneous (Pfirrmann Grade I) than in inhomogeneous (Grade II) IVDs. The distance on the perpendicular axis in Grade III IVDs was significantly larger than that in Grade I and Grade II IVDs. The relationship between the weighted and geometric centers can serve as an indicator for NP homogeneity. The distance between both centers through advancing stages of degeneration demonstrated decrease of signal intensity progressing along the longitudinal axis initially and then along the cranio-caudal direction at later stages. These findings could provide insights of initiation and subsequent progression of degenerative changes in IVDs.