Microwave imaging has recently drawn increasing attention due to its potential for rapid stroke diagnosis using this low-cost, and non-ionizing modality. Besides, this modality can be built as a portable scanning device that can be utilized for both on-site and in-hospital settings. Over the past few years, there have been great efforts by many scientists and engineers to translate this life-saving technology to a clinical setting. Although recent progress indicates that microwave imaging has indeed evolved at a rapid pace, there are still several challenges to be addressed. This paper discusses the recent progress in addition to challenges and limitations that must be overcome to enable the development of clinical systems for stroke diagnosis with robust and reliable results. It provides a comprehensive review of recent systems, focusing on complete systems and processing algorithms.
19 May 2016 in IEEE Microwave and Wireless Components Letters
A compact wideband four-way filtering PD is presented. The structure of the proposed device includes a pair of looped coupled-line structures to provide the needed power division to four output ports. Moreover, a pair of short-ended coupled-line stubs is used to introduce multiple transmission poles and transmission zeros for a sharp cut-off of the passband and high upper-stopband rejection. A detailed design procedure is shown to determine the initial design parameters. A prototype is designed, simulated and measured experimentally. The measured results show 56.5% bandwidth centered at 1.5 GHz with more than 15 dB upper-stopband rejection up to 4.15 GHz, more than 13 dB in-band isolation, and 15 dB return loss at all output ports.
13 January 2014 in IEEE Microwave and Wireless Components Letters
Compact planar phase shifters with wide range of differential phase shift across ultra-wideband frequency are proposed. To achieve that performance, the devices use broadside coupled structure terminated with open-ended or short-ended stubs. The theory of operation for the proposed devices is derived. To validate the theory, several phase shifters are designed to achieve a differential phase ranging from -180° to 180°. Moreover, three prototypes are developed and tested. The simulated and measured results agree well with the theory and show less than 7° phase deviation and 1.4 dB insertion loss across the band 3.1-10.6 GHz.
22 July 2016 in IEEE Microwave and Wireless Components Letters
A planar broadband phase shifter with wide range of differential phase is proposed. To achieve this performance, the design uses quarter wavelength parallel coupled lines combined with two L-shape networks. The L-shaped network includes a short-ended stub and a section of transmission line as an impedance transformer. The value of the differential phase can be adjusted through varying the coupling coefficient of the coupled lines along with the length and impedance of the short-ended stubs and transformer. The theory of operation for the proposed design is explained. To validate the theory, a phase shifter is designed and manufactured to realize 180° differential phase. The simulated and measured results agree well with the theory and show less than b° phase deviation and 1.3 dB insertion loss across the band 1-3 GHz.
22 October 2021 in IEEE Transactions on Biomedical Engineering
A modified distorted Born iterative method (DBIM), which includes clustering of reconstructed electrical properties (EPs) after certain iterations, is presented for brain imaging aiming at stroke detection and classification. For this approach to work, a rough estimation of number of different materials (or bio-tissues) in the imaged domain and their corresponding rough dielectric properties (permittivity and conductivity) are needed as a prior information. The proposed adaptive clustering DBIM (AC-DBIM) is compared with three conventional methods (DBIM, multiplicative regularized contrast source inversion (MR-CSI), and CSI for shape and location reconstruction (SL-CSI)) in two-dimensional scenario on a head phantom and numerical head model with different strokes. Three-dimensional simulations are also conducted to indicate the suitability of AC-DBIM in real-life brain imaging. Lastly, the proposed algorithm is assessed using a clinical electromagnetic head scanner developed on phantoms. The simulation and experimental results show superiority of AC-DBIM compared to conventional methods. AC-DBIM achieves significant improvement in the size and shape reconstruction and reduction in errors and standard deviation of the reconstructed ${\varepsilon _r}$ and $\sigma $ at clinical scenarios compared with conventional DBIM.
18 May 2020 in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
Identifying stroke subtypes from electromagnetic imaging systems is usually based on frequency domain using radar or tomography algorithms which is computationally expensive. This paper presents a novel graph degree mutual information (GDMI) approach to distinguish Intracranial Haemorrhage (ICH) from Ischemic Stroke (IS). A total of 50 ICH and 50 IS signals simulated using a 16-antenna electromagnetic head imaging system are analysed to evaluate GDMI. The data collected from each model consists of 256 reflected and received signal. Subsequently, noise is injected into the collected signals to generate three groups of signals with different signal-to-noise ratios (40 dB, 25 dB and 10 dB SNR), to emulate measurement noise and to test the algorithm's robustness. Each signal is converted into a graph to avoid the variable signal amplitudes. Then, the relationship between each pair of graph degrees is calculated by mutual information and forwarded to a support vector machine to identify stroke type. The results indicate that signals from ICH subjects exhibit a significantly higher GDMI compared to the IS group ($p<; 0.01$). An accuracy of 88% is achieved in identifying ICH from IS without the need to use time- and resource-expensive brain image reconstruction algorithms even under 25 dB signal-to-noise levels. The execution time for graph feature extraction and classification is less than one minute on a PC. Such a short time is suitable for stroke emergency requirements.