9 September 2019 in IEEE Transactions on Antennas and Propagation
An approach towards designing and building of compact low-profile, wideband, unidirectional and conformal imaging antenna for electromagnetic (EM) head imaging systems is presented. The approach includes the realization of a custom-made flexible high-permittivity dielectric substrate to achieve a compact sensing antenna. The developed composite substrate is built using silicon-based poly-di-methyl-siloxane (PDMS) matrix and microscale of aluminium oxide (Al2O3) and graphite (G) powders. Al2O3 and G powders are used as fillers with different weight-ratio to manipulate and control the dielectric properties of the substrate for attaining better matched with the human head and reducing antenna’s physical size while keeping the PDMS flexibility feature. Using the custom-made substrate, a compact, wideband, and unidirectional on-body matched antenna for wearable EM head imaging system is realized. The antenna is configured as a multi-slot planar structure with four shorting pins, working as electric and magnetic dipoles at different frequency bands. The measured reflection coefficient (S11) shows an operating frequency band of 1 -4.3 GHz. The time-average power density and the amplitude of the received signal inside the MRI-based realistic head phantom demonstrate a unidirectional propagation and high-fidelity factor of more than 90%. An array of 13 antennas are fabricated and tested on a realistic 3D head phantom to verify the imaging capability of the proposed antenna. The reconstructed images of different targets inside the head phantom demonstrate the possibility of utilizing the conformal antenna arrays to detect and locate abnormality inside the brain using multistatic Delay-Multiply-And-Sum beamforming algorithm.
18 November 2020 in IEEE Transactions on Antennas and Propagation
Portable light-weight electromagnetic head imaging systems for brain stroke detection are of great interest due to the need for fast and low-cost diagnosis tools. This paper presents a wideband and compact flexible meander-line antenna array for a wearable electromagnetic head imaging system. The antenna is designed and optimized on a 4-mm thick low-cost, flexible room-temperature-vulcanizing (RTV) silicone substrate in close vicinity to a multi-tissue head model. The antenna comprises two sections of meander-lines, a full ground plane, and a 50 Ω coaxial connector. The measured reflection coefficient |S11| on a human head shows that the proposed antenna operates effectively across the frequency band of 0.45-3.6 GHz, attaining fractional bandwidth (FBW) of 155%. The antenna achieves unidirectional radiations with greater than 9 dB of front-to-rear-ratio in the near field region, and safe-level maximum SAR below 0.2 W/kg using an input power of 10 dBm. A 16-element antenna array was assembled and experimentally utilized in an electromagnetic head imaging system. The reconstructed images of abnormality-emulating targets using a confocal imaging algorithm demonstrate the feasibility of utilizing such flexible and light-weight antennas for wearable electromagnetic head imaging systems.
25 February 2019 in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
Head imaging plays an imperative role in the detection and localisation of conditions affecting the brain, such as strokes, cancerous tumours, and haemorrhages caused by trauma. Current systems require the patient to be transported to the imaging device which increases the time taken to apply treatments, allowing the patient's condition to worsen. This paper proposes a portable microwave head imaging system that can easily be taken to the patient. The system utilises a novel combination of a software-defined radio and solid-state switching network to collect the imaging data, and operates in the frequency band of 0.85 - 2 GHz. It can capture input signals over a range of approximately 106 dB, which is suitable for detecting realistic brain injuries. The concept has been validated through experimental data collection and confocal image generation, and was capable of producing images in less than a minute. A simplified head phantom was developed for gathering the verification data and proved that the system was capable of locating targets with dielectric properties similar to brain tumours and bleeds. The presented design is highly accessible, achieved through being small, light, and inexpensive: key factors that could help save lives in time-critical medical emergencies.
22 October 2021 in IEEE Transactions on Biomedical Engineering
A modified distorted Born iterative method (DBIM), which includes clustering of reconstructed electrical properties (EPs) after certain iterations, is presented for brain imaging aiming at stroke detection and classification. For this approach to work, a rough estimation of number of different materials (or bio-tissues) in the imaged domain and their corresponding rough dielectric properties (permittivity and conductivity) are needed as a prior information. The proposed adaptive clustering DBIM (AC-DBIM) is compared with three conventional methods (DBIM, multiplicative regularized contrast source inversion (MR-CSI), and CSI for shape and location reconstruction (SL-CSI)) in two-dimensional scenario on a head phantom and numerical head model with different strokes. Three-dimensional simulations are also conducted to indicate the suitability of AC-DBIM in real-life brain imaging. Lastly, the proposed algorithm is assessed using a clinical electromagnetic head scanner developed on phantoms. The simulation and experimental results show superiority of AC-DBIM compared to conventional methods. AC-DBIM achieves significant improvement in the size and shape reconstruction and reduction in errors and standard deviation of the reconstructed ${\varepsilon _r}$ and $\sigma $ at clinical scenarios compared with conventional DBIM.
21 September 2020 in IEEE Transactions on Biomedical Circuits and Systems
A wideband wearable electromagnetic (EM) head imaging system for brain stroke detection is presented. The proposed system aims at overcoming the challenges of size, rigidity, and complex structures of existing systems. The proposed system is built into a light-weight and compact imaging platform, which integrates a 16-element antenna array into a highly flexible custom-made wearable cap made of a cost-effective and robust room-temperature-vulcanizing (RTV) silicone. The system mitigates the mismatch between the skin and antenna array by introducing a flexible high-permittivity matching layer. The utilized compact antenna demonstrates wideband operational frequency over 0.6-2.5 GHz with a low signal distortion, safe values of SAR, and unidirectional radiations. The system is experimentally validated on realistic head phantoms. The polar sensitivity encoding (PSE) image processing algorithm is utilized to generate 2D images of different testing scenarios. The obtained images of a stroke-like target inside the head phantoms demonstrate the merits and feasibility of the system for preclinical trials.
2 December 2021 in IEEE Transactions on Medical Imaging
The clinical use of microwave tomography (MT) requires addressing the significant mismatch between simulated environment, which is used in the forward solver, and real-life system. To alleviate this mismatch, a calibrated tomography, which uses two homogeneous calibration phantoms and a modified distorted Born iterative method (DBIM), is presented. The two phantoms are used to derive a linear model that matches the forward solver to real-life measurements. Moreover, experimental observations indicate that signal quality at different frequencies varies between different antennas due to inevitably inconsistent manufacturing tolerance and variances in radio-frequency chains. An optimum frequency, at which the simulated and measured signals of the antenna present maximum similarity when irradiating the calibrated phantoms, is thus calculated for each antenna. A frequency-division DBIM (FD-DBIM), in which different antennas in the array transmit their corresponding optimum frequencies, is subsequently developed. A clinical brain scanner is then used to assess performance of the algorithm in lab and healthy volunteers’ tests. The linear calibration model is first used to calibrate the measured data. After that FD-DBIM is used to solve the problem and map the dielectric properties of the imaged domain. The simulated and experimental results confirm validity of the presented approach and its superiority to other tomographic method.