Edgard Jabbour

Prof. Edgard Jabbour


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Journal of International Society of Preventive and Community Dentistry
Verified
Journal Article
Open access
PDF file
JSJoseph Sabbagh
Joseph Sabbagh
FNFidele Nabbout
Fidele Nabbout
EJEdgard Jabbour
Edgard Jabbour
GLGaetane Leloup
Gaetane Leloup
Objective: The aim of this in vitro study is to evaluate the effect of expiration date on some mechanical properties of resin composites after controlled storage of syringes and compules in a refrigerator at 4°C. Materials and Methods: Specimens were tested at 7 days after storage in distilled water at room temperature. The investigated properties are the static modulus of elasticity, the flexural strength, and the Vickers microhardness. Same batches of restorative materials were examined at baseline (at least 1 year before their expiration date) and 1 year after they expired. Results: Paired t-test is used to compare the results between the two groups using StatView software (version 5.0) SAS Campus Drive Cary, North Carolina, USA. Except for the flexural strength, no statistical differences were found between the mechanical properties of the expired and the unexpired group. Conclusion: The 1-year expiry date did not seem to affect the investigated mechanical properties.

15 February 2019 in Australian Endodontic Journal
Verified
Journal Article
Closed access
PDF file
MFMaya Feghali
Maya Feghali
EJEdgard Jabbour
Edgard Jabbour
EKEdmond Koyess
Edmond Koyess
JSJoseph Sabbagh
Joseph Sabbagh

26 August 2020 in European Journal of Dentistry
Verified
Journal Article
Open access
PDF file
SYSalwa Daoud Yammine
Salwa Daoud Yammine
EJEdgard Jabbour
Edgard Jabbour
Objectives This in vitro study aimed to compare the amount of mixed and dried debris extruded with three endodontic NiTi (nickel–titanium) systems at three levels beyond the major apical foramen. The null hypothesis is that there would be no differences between the different rotary systems in terms of apically extruded debris. Materials and Methods Forty-eight roots of human extracted molars with 20 to 40-degrees curvature were divided randomly into three groups (n = 16) instrumented with ProTaper Next, BT RaCe, and WaveOne Gold, respectively. Instrumentation was performed at the major foramen and over instrumented 0.5 mm, 1.0 mm and 1.5 mm beyond. Irrigation was performed with sodium hypochlorite. Apically extruded debris was collected. Results Comparison of mixed extruded debris (solution/debris)and dried debris according to group and level of instrumentation showed that WaveOne Gold at the foramen and ProTaper Next beyond the foramen (p < 0.0001) resulted in significantly less extruded debris than other files and within the four levels using repeated measures analysis of variance (p < 0.0001b). Conclusions All systems exhibit extruded debris during instrumentation but in different amounts.

10 October 2017
Verified
Journal Article
Open access
SYSalwa Daoud Yammine
Salwa Daoud Yammine
EJEdgard Jabbour
Edgard Jabbour
PNPaul Nahas
Paul Nahas
ZMZeina Majzoub
Zeina Majzoub
The present in vitro study aimed to evaluate and compare the changes in shape and surface area of the major foramen following shaping of curved canals with three new generation NiTi engine-driven instruments naming ProTaper Next, BT RaCe and WaveOne Gold- with 3 different levels of protrusion beyond the major apical foramen. A total of 45 extracted human molars with at least one curved canal were distributed in 3 comparable groups of 15 that were instrumented using either ProTaper Next (PTN), BT RaCe (BTR) or WaveOne Gold (WOG). The canals were instrumented to the major foramen and then over instrumented with the final file 0.5 mm, 1 mm and 1.5 mm beyond the foramen. Standardized pre- and post-instrumentation photographs of the foramen were obtained for all groups using a stereomicroscope. Foramen shape and surface area were evaluated using the AmScope software for measurements and compared between groups and levels of instrumentation applying binary conditional logistic regression and repeated measures ANOVA. The level of significance was set at 0.05. Foramen shape tended to gradually change from circular to oval as the level of instrumentation increased in all groups. The original foramen shape in WOG group remained better than other groups. Foramen surface areas increased in all groups with Group BTR demonstrating significantly greater values than the other 2 groups. Over instrumentation resulted in apical enlargement and ovalization in all 3 groups but with different patterns. These differences can be attributed to the final file size, design characteristics and kinematics of the 3 systems.

2 May 2018 in Scientifica
Verified
Journal Article
Open access
PDF file
SYSalwa Yammine
Salwa Yammine
EJEdgard Jabbour
Edgard Jabbour
STSami Assaad El Toum
Sami Assaad El Toum
ACAntoine Cassia
Antoine Cassia
Objective.Diode lasers have multiple indications in everyday dental practice. They allow carrying out incisions, coagulation of soft tissue, and Low-Level Laser Therapy. The goal of this study is to compare histologically the tissue interaction zones and edges of an induced laser incision on rabbits’ tongues with three different wavelengths of 810, 940, and 980 nm in continuous mode.Methods.Fourteen male rabbits were divided into six groups. Each animal underwent three incisions of 10 mm length on the right ventral face of the tongue, carried out in continuous mode with three diode lasers with different wavelengths of 810, 940, and 980 nm. Rabbits were sacrificed at 0, 1, 2, 6, and 15 hours and 14 days. Five rabbits were sacrificed at 0 hours and 2 hours and one rabbit was sacrificed at 1, 6, and 15 hours and at 14 days. The appearance of neutrophils marked the onset time of the inflammatory reaction. Histological study of the incisions was chosen to evaluate the edges and to measure the depth and width of carbonization and necrotic and inflammatory zones. Healing was evaluated at 14 days. Friedman test was used to assess statistical differences between groups.Results.In the experimental adopted conditions, the carbonization zone was marked by degradation of vacuoles and an elongation of nuclei and was observed on the edges of incisions. Carbonization and necrotic and inflammatory zones were measured for rabbits sacrificed at 0, 1, 2, 6, and 15 hours but the onset of inflammation zone marked by the infiltration of neutrophils did not appear before 6 hours. The neutrophils infiltration was higher at 15 hours than at 6 hours. Complete healing was shown at 14 days. According to the time for the regularity of the edges, the interpretation was qualitative without a statistical test. The statistical analysis of the three different diode lasers in this study showed nonsignificant difference between the different groups for the depth (p=0.121) and width (p=0.376) of the incisions, the carbonization zone (p=0.692), and the necrotic zone (p=0.223). For the inflammation zone at 6 and 15 hours, statistical analysis was not carried out; only one rabbit was enough to evaluate onset of neutrophils infiltration and to compare its density for 6 and 15 hours.Conclusion.These results indicate that diode laser used in the continuous mode is predictable for induced incision. The use of three diode lasers with different wavelengths of 810, 940, and 980 nm did not reveal a significant statistical difference according to depth and width of the incision and for carbonization and necrotic zone. The appearance of neutrophils was marked between 4 and 6 hours and was higher at 15 hours.

1 January 2018 in Journal of International Society of Preventive and Community Dentistry
Verified
Journal Article
Open access
PDF file
SYSalwa Yammine
Salwa Yammine
EJEdgard Jabbour
Edgard Jabbour
FDFranck Diemer
Franck Diemer
ZMZeina Majzoub
Zeina Majzoub
Aim: The aim of the present in vitro study to compare canal straightening following shaping of curved canals with three types of new generation nickel-titanium (NiTi) rotary instruments-ProTaper Next (PTN)®, BT RaCe (BTR)®, and WaveOne Gold (WOG)®- and three different levels of protrusion beyond the major apical foramen. Materials and Methods: Forty-five extracted human maxillary and mandibular molars with at least one curved canal were distributed in three comparable groups of 15 canals each. The canals were instrumented to the major foramen and then overinstrumented with the final file 0.5 mm, 1 mm, and 1.5 mm beyond the foramen using PTN (Group PTN = 15), BTR (Group BTR = 15), and WOG (Group WOG = 15). Standardized pre- and post-instrumentation radiographs of the root canal were obtained for all groups using digital intraoral radiographs coupled with software. Differences in the degree of curvature were regarded as straightening and canal curvature was evaluated based on Schneider technique using the AmScope software for measurements and compared between groups and levels of instrumentation applying Mixed-model ANOVA. Significance was set at 0.05. Results: Canal curvature tended to gradually straighten out as the level of instrumentation increased in all three groups without statistically significant difference among the groups (P = 0.826). Conclusion: Overinstrumentation in curved canals resulted in straightening of the canal curvature.