Emilio González-Arnay

Dr. Emilio González-Arnay


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 June 2023 in Photonics
Verified
Journal Article
Open access
PDF file
JGJose J. Gil
Jose J. Gil
IJIgnacio San Jose
Ignacio San Jose
MCMónica Canabal-Carbia
Mónica Canabal-Carbia
IEIrene Estévez
Irene Estévez
EGEmilio González-Arnay
Emilio González-Arnay
ÁLÁngel Lizana
Ángel Lizana
Polarimetric techniques are widely used in a vast number of applications such as remote sensing, material characterization, astronomy and biological tissue inspection. In this last scenario, different polarimetric observables have proved their potential for enhancing imaging visualization. In this work we use a set of polarimetric observables derived from the arrow decomposition of the Mueller matrix for the first time: enpolarizing, retarding and depolarizing descriptors. In particular, the mean intensity coefficient and the three indices of polarimetric purity, the absolute values and Poincaré orientations of diattenuation, polarizance, entrance retardance and exit retardance vectors are considered. Results show images with enhanced visualization or even revealing invisible structures when compared to standard intensity images. In particular, thanks to these metrics, we improve the visualization of the necrotic areas of a Vitis rupestris leaf. In the case of animal samples, boundaries between different fascicles inside a tendon of an ex vivo chicken sample are revealed, as is the directionality of fiber tracts of the subcortical white matter in an ex vivo cow brain. The experimental results show the potential for biophotonics imaging and how polarimetric techniques could be useful for biomedical and botanical applications.

1 January 2022 in Annals of Anatomy - Anatomischer Anzeiger
Verified
Journal Article
Closed access
EGEmilio González-Arnay
Emilio González-Arnay
Felice GalluccioFelice Galluccio
Felice Galluccio
IPIsabel Pérez-Santos
Isabel Pérez-Santos
SMSebastián Merlano-Castellanos
Sebastián Merlano-Castellanos
EBElena Bañón-Boulet
Elena Bañón-Boulet
MPMario Fajardo Pérez
Mario Fajardo Pérez

1 November 2020 in Journal of Forensic and Legal Medicine
Verified
Journal Article
Closed access
EGEmilio González-Arnay
Emilio González-Arnay
RMRaquel Martín-Olivera
Raquel Martín-Olivera
YQYamilet C. Quintero-Quintero
Yamilet C. Quintero-Quintero
AHAna I. Hernández-Guerra
Ana I. Hernández-Guerra

Verified
Journal Article
Open access
PDF file
EGEmilio González-Arnay
Emilio González-Arnay
IPIsabel Pérez-Santos
Isabel Pérez-Santos
CBCamino Braojos-Rodríguez
Camino Braojos-Rodríguez
APArtimes García Parra
Artimes García Parra
EBElena Bañón-Boulet
Elena Bañón-Boulet
MFMario Fajardo-Pérez
Mario Fajardo-Pérez
Background: The coracohumeral ligament (CHL) is inserted in the coracoid process, from which it extends laterally and caudally, blending with the tendinous insertions of the subscapularis muscle and the supraspinatus muscle, with a third intermediate area between the muscles inserted between the humeral tubercles, and it contributes to the fibrous tunnel that engulfs the long head of the biceps tendon. Most previous studies mention insertions from the base of the coracoid process, but not from the tip, and some authors describe anterior and posterior columns. In contrast, others stress the existence of superficial and deep fascicles. Also, the relationship between the coracohumeral and the glenohumeral ligaments is unclear. Given the position of the CHL covering most of the rotator interval, and its role in the stability of the shoulder capsule and pathologies like frozen shoulder, a clear description of its fascicles in a plane-wise manner might be helpful for a selective surgical approach. Methods: We studied sixteen soft-embalmed shoulders to avoid misclassifying fascicles due to formalin-linked tissue amalgamation. Further histological assessment was performed on the two remaining non-embalmed shoulders. Results: In our sample, the coracohumeral ligament hung from the anterior and posterior edges of the coracoid process’ inferior surface, defining two columns that converged near the tip of the coracoid process. Both columns were formed by superficial and deep fascicles directed to different depths of the rotator cuff, usually via the rotator interval, fusing with the connective tissue around the muscles without direct distal attachments. We performed histological and morphometrical assessments, and we discuss clinical and biomechanical implications. Conclusions: The coracohumeral ligament contains four fascicles that fuse with the connective tissue of the shoulder joint, forming a double necklace around the subscapularis and supraspinatus. Therefore, its functions probably extend beyond simple vertical stabilization.


Verified
Journal Article
Open access
PDF file
EGEmilio González-Arnay
Emilio González-Arnay
APArtimes García Parra
Artimes García Parra
IPIsabel Pérez-Santos
Isabel Pérez-Santos
MOMaryé Mercé Méndez Ojeda
Maryé Mercé Méndez Ojeda
EBElena Bañón-Boulet
Elena Bañón-Boulet
MFMario Fajardo-Pérez
Mario Fajardo-Pérez
Background: The glenohumeral ligaments are key stabilizers of the glenohumeral joint. Three distinct fascicles are usually described from the anterior surface of the shoulder joint: a superior glenohumeral ligament (SGHL); a middle glenohumeral ligament (MGHL); and an anteroinferior glenohumeral ligament (AIGHL). A remarkable interindividual variation has been reported, and there are few data about the patterns of insertion of these ligaments. A recent study provided a much-needed insight into the quantitative details of the glenohumeral ligament insertions. However, there is a lack of studies describing linear measurements (closer to real-life surgical anatomy) of glenohumeral ligamentous insertions according to their pattern. Methods: Hereby, we present a Thiel-based anatomical study describing proximal (glenoid) insertions of glenohumeral ligaments in 39 specimens from volunteer body donors to the Applied Anatomy Laboratory at the Autonomous University of Madrid. Results: Only 30.8% of cases showed a canonical pattern of SGHL, MGHL, and AIGHL, with scapular insertions ranging from 0.28 to 1.58 cm for SGHL, 0.1–3.6 cm for MGHL, and 0.45–2.05 cm for AIGHL, frequently mixed between the labrum and the osseous edge of the glenoid surface. Most cases show a single glenohumeral ligament inserted, usually in the labrum. A wide range of patterns regarding the number of insertions and their labral or osseous nature is present in our sample. Conclusions: Overall, there are three different patterns of glenohumeral ligaments in the anterior aspect of the shoulder joint, with the canonical pattern (three ligaments) represented in less than half of the cases. The morphometric study of the glenohumeral ligaments should consider their pattern of distribution. Also, insertions vary between the labrum and the scapular osseous articular surface.