Yaqi Deng

Dr. Yaqi Deng


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 February 2024 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Open access
HSHongchun Shu
Hongchun Shu
YDYaqi Deng
Yaqi Deng
PCPulin Cao
Pulin Cao
MZMengmeng Zhu
Mengmeng Zhu
NANa An
Na An
GWGuangxue Wang
Guangxue Wang

31 July 2023 in Energies
Verified
Journal Article
Open access
PDF file
MZMengmeng Zhu
Mengmeng Zhu
HTHongda Tang
Hongda Tang
ZHZhaolei He
Zhaolei He
YLYaohua Liao
Yaohua Liao
BTBiao Tang
Biao Tang
PCPulin Cao
Pulin Cao
DC electronic current transformer is the data source of the system control and protection device, so its measurement delay has always been concerned. In this paper, the DC current transformer is modelled equivalently and the key factors affecting the delay of shunt and the remote module are analyzed. A field test method for the delay characteristics of the DC electronic current transformer is proposed. Moreover, a complex multi-state large current generator and integrated test system are developed. On the basis of the IEC 60044-8 standard transmission protocol, the accuracy of standard signal acquisition with the shunt is better than 0.2%. The maximum output current of the established testing system is 600 A. Based on the field test in an actual HVDC project, transient step and various frequency signal components are applied for analyzing.

11 May 2021 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Closed access
PDF file
HSHongchun Shu
Hongchun Shu
YDYaqi Deng
Yaqi Deng
JDJun Dong
Jun Dong
PCPulin Cao
Pulin Cao
Bo YangBo Yang
Bo Yang
ZBZhiqian Bo
Zhiqian Bo
The vigorous development of renewable energy has induced multiple sources connected to regional distribution networks. However, the high impedance ground fault that appeared in the distribution network can induce an intermittent arc accompanied by extinction and reignition, which may damage renewable energy generation devices severely. Therefore, the detection of arcing faults is profoundly necessary for practice, but the high impedance arcing fault is easily confused with switches of motor or capacitor bank. In order to solve high impedance arcing fault detection, this paper proposes a high impedance arcing fault detection method that combines complete ensemble empirical mode decomposition with adaptive noise (CEEMDAN) and Teager energy operator (TEO). Firstly, CEEMDAN algorithm is used to extract the intrinsic mode function (IMF) of transient zero‐sequence current (TZSC). According to the correlation coefficient and waveform similarity, which can select maximum correlation coefficient value as the characteristic component of TZSC; Then, TEO is utilized to track the change of signal in real‐time, meanwhile, wavelet singular entropy (WSE) is applied to calculate the characteristic component of TZSC. In particular, high impedance arcing fault (HIAF), motor switching (MS), and capacitor bank switching (CBS) can be effectively identified by comparing WSE. The effectiveness of CEEMDAN‐TEO detection method is verified by simulation, which owns advantages in extraction accuracy, calculation efficiency, and detection accuracy of feature components.

7 November 2025 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Open access
YDYaqi Deng
Yaqi Deng
HSHongchun Shu
Hongchun Shu
PCPulin Cao
Pulin Cao
MZMengmeng Zhu
Mengmeng Zhu