Pulin Cao

Dr. Pulin Cao


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
PCPulin Cao
Pulin Cao
HSHongchun Shu
Hongchun Shu
Bo YangBo Yang
Bo Yang
YFYi Fang
Yi Fang
YHYiming Han
Yiming Han
TYTao Yu
Tao Yu

9 July 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MDMin Ding
Min Ding
DLDong Lv
Dong Lv
CYChen Yang
Chen Yang
PCPulin Cao
Pulin Cao
QFQi Fang
Qi Fang
XZXiaoshun Zhang
Xiaoshun Zhang
This paper aims to introduce a novel maximum power point tracking (MPPT) strategy called transfer reinforcement learning (TRL), associated with space decomposition for Photovoltaic (PV) systems under partial shading conditions (PSC). The space decomposition is used for constructing a hierarchical searching space of the control variable, thus the ability of the global search of TRL can be effectively increased. In order to satisfy a real-time MPPT with an ultra-short control cycle, the knowledge transfer is introduced to dramatically accelerate the searching speed of TRL through transferring the optimal knowledge matrices of the previous optimization tasks to a new optimization task. Four case studies are conducted to investigate the advantages of TRL compared with those of traditional incremental conductance (INC) and five other conventional meta-heuristic algorithms. The case studies include a start-up test, step change in solar irradiation with constant temperature, stepwise change in both temperature and solar irradiation, and a daily site profile of temperature and solar irradiation in Hong Kong.

1 August 2019 in Processes
Verified
Journal Article
Open access
PDF file
YJYueping Jiang
Yueping Jiang
XJXue Jin
Xue Jin
HWHui Wang
Hui Wang
YFYihao Fu
Yihao Fu
PCPulin Cao
Pulin Cao
TYTao Yu
Tao Yu
Voltage source converter (VSC) has been extensively applied in renewable energy systems which can rapidly regulate the active and reactive power. This paper aims at developing a novel optimal nonlinear adaptive control (ONAC) scheme to control VSC in both rectifier mode and inverter mode. Firstly, the nonlinearities, parameter uncertainties, time-varying external disturbances, and unmodelled dynamics can be aggregated into a perturbation, which is then estimated by an extended state observer (ESO) called high-gain perturbation observer (HGPO) online. Moreover, the estimated perturbation will be fully compensated through state feedback. Besides, the observer gains and controller gains are optimally tuned by a recent emerging biology-based memetic salp swarm algorithm (MSSA), the utilization of such method can ensure a desirably satisfactory control performance. The advantage of ONAC is that even though the operation conditions are constantly changing, the control performance can still be maintained to be globally consistent. In addition, it is noteworthy that in rectifier mode only the reactive power and DC voltage are required to be measured, while in inverter mode merely the reactive power and active power have to be measured. At last, in order to verify the feasibility of ONAC in practical application, a hardware experiment is implemented.

15 October 2020 in IEEE Access
Verified
Journal Article
Open access
NANa An
Na An
HSHongchun Shu
Hongchun Shu
Bo YangBo Yang
Bo Yang
PCPulin Cao
Pulin Cao
JSJian Song
Jian Song
YGYu Guo
Yu Guo
Through analysis of various fault voltage characteristics of modular multilevel converter high voltage direct current (MMC-HVDC) transmission system, it shows that the positive and negative voltage relationships of direct current transmission lines with single pole-to-ground faults are obviously different from other faults. Hence, Pearson correlation coefficient is used to describe the degree of difference in this work. In the case of single pole-to-ground fault, correlation coefficient is positive and close to 1, while as for other failures, correlation coefficient is negative and close to −1. This article analyzes the mechanism of correlation coefficient to withstand transition resistance and verifies the effectiveness of the proposed method under high resistance grounding fault. A novel scheme is proposed by combining the quantity sum of voltage variation characteristics, which can effectively identify fault pole. The proposed scheme needs smaller time window and owns high efficiency, as well as great robustness to transition resistance.

22 March 2020 in Energies
Verified
Journal Article
Open access
PDF file
HSHongchun Shu
Hongchun Shu
YHYiming Han
Yiming Han
RHRan Huang
Ran Huang
YTYutao Tang
Yutao Tang
PCPulin Cao
Pulin Cao
YZYu Zhang
Yu Zhang
Due to the complex structure of the T-connection transmission lines, it is extremely difficult to identify the reflected travelling wave from the fault point and that from the connection point by the measurement from only one terminal. According to the characteristics of the structure of the T-connection transmission line, the reflection of the travelling wave within the line after the failure of different sections in T-connection transmission line are analyzed. Based on the lattice diagram of the travelling wave, the sequence of travelling waves detected at the measuring terminal varies with the fault distance and the faulty section. Moreover, the sequence of travelling waves detected in one terminal is unique at each faulty section. This article calculates the arrival time of travelling waves of fault points at different locations in different sections to form the collection of the travelling wave arrival time sequence. Then the sequence of travelling waves of the new added fault waveforms is extracted to compare with the sequences in the collection for the faulty section identification and fault location. This proposed method can accurately locate the fault with different fault types, fault resistances and system impedances by only single-terminal fault data. Both Power Systems Computer Aided Design/ Electromagnetic Transients including DC (PSCAD/EMTDC) and actual measurement data are implemented to verify the effectiveness of this method.

30 April 2025 in Processes
Verified
Journal Article
Open access
PDF file
ZSZe Shi
Ze Shi
HWHao Wu
Hao Wu
TXTianxiang Xiao
Tianxiang Xiao
XHXiliu Huang
Xiliu Huang
LSLong Shao
Long Shao
PCPulin Cao
Pulin Cao
With the widespread adoption of highways in the mountainous regions of southwestern China, the electricity load of numerous tunnels and service areas has increased rapidly. Constructing photovoltaic (PV) microgrids in service areas has become an important means of energy conservation, consumption reduction, and carbon emission mitigation. However, constrained by mountainous terrain, the PV power generation conditions in highway service areas exhibit significant micro-terrain variations, making it difficult to effectively evaluate PV utilization efficiency. This paper proposes a dynamic block optimization model for PV microgrids that considers regional layout constraints. The model utilizes an intelligent adjustment mechanism to plan PV panel layouts in highway service areas, optimizing energy utilization efficiency and economic benefits. Additionally, long short-term memory (LSTM) networks are employed for short-term PV output prediction to address the challenges posed by varying weather and seasonal changes. This approach comprehensively considers the intermittency and instability of PV power generation, enabling dynamic block optimization to autonomously adjust the PV power output in response to load fluctuations. Through simulation case studies, the model is validated to effectively improve the utilization rate and economic performance of PV microgrids under various environmental conditions and demonstrates superior performance compared with traditional static block methods.