The Absolute Radiance Interferometer (ARI) is an infrared spectrometer designed to serve as an on-orbit radiometric reference with the ultra-high accuracy (better than 0.1 K 3‑σ or k = 3 brightness temperature at scene brightness temperature) needed to optimize measurement of the long-term changes of Earth’s atmosphere and surface. If flown in an orbit that frequently crosses sun-synchronous orbits, ARI could be used to inter-calibrate the international fleet of infrared (IR) hyperspectral sounders to similar measurement accuracy, thereby establishing an observing system capable of achieving sampling biases on high-information-content spectral radiance products that are also < 0.1 K 3‑σ. It has been shown that such a climate observing system with <0.1 K 2‑σ overall accuracy would make it possible to realize times to detect subtle trends of temperature and water vapor distributions that closely match those of an ideal system, given the limit set by the natural variability of the atmosphere. This paper presents the ARI sensor's overall design, the new technologies developed to allow on-orbit verification and test of its accuracy, and the laboratory results that demonstrate its capability. In addition, we describe the techniques and uncertainty estimates for transferring ARI accuracy to operational sounders, providing economical global coverage. Societal challenges posed by climate change suggest that a Pathfinder ARI should be deployed as soon as possible.
High spectral resolution infrared sounders are an integral component of the global observing system and are used in a broad range of applications. This is enabled by their high accuracies which are ensured by rigorous calibration/validation activities. One of these activities is the post‐launch intercomparison with other high spectral resolution infrared sounders using simultaneous nadir overpasses (SNOs). This paper introduces a novel application of the previously developed SNO methodology by including time difference histogram symmetrization and a spatial sampling uncertainty. Where possible, radiometric measurement uncertainties are included and propagated through the statistics. Comparisons of Atmospheric Infrared Sounder (AIRS), METOP‐A/B/C Infrared Atmospheric Sounding Interferometer (IASI), and Cross‐track Infrared Sounder (CrIS) from 1 October 2019, to 1 October 2020, are analyzed. Results show AIRS and IASI differences as well as CrIS and AIRS differences are generally less than 0.4 K across the spectrum, and CrIS and IASI differences are generally less than 0.25 K. Comparison of the Suomi National Polar‐Orbiting Partnership and NOAA‐20 CrIS instruments via IASI and AIRS shows differences are generally less than 0.1 K across all bands and that the two CrIS instruments statistically agree within their radiometric uncertainties except for the narrow 2,370 cm−1 region where artifacts due to brightness temperature conversion are prone to occur.
1 July 2012 in Journal of Quantitative Spectroscopy and Radiative Transfer
The Cross-track Infrared Sounder (CrIS) is an infrared Fourier-transform spectrometer that measures the Earth’s infrared radiance at high spectral resolution and high accuracy. The potential for polarization errors contributing significantly to the radiometric uncertainty of infrared remote sounders has been well recognized and documented, particularly due to polarization-dependent scene select mirrors operated in conjunction with grating-based instruments. The issue is equally applicable to FTS-based sensors. While the CrIS sensor utilizes an unprotected gold scene select mirror which has extremely low polarization in the infrared and the angle of incidence at the mirror is maintained for all calibration and Earth scene views, the radiometric bias due to polarization effects was determined to be non-negligible for cold scenes. A model for the polarization-induced calibration bias and the associated correction is presented for the CrIS instrument, along with details of the model parameter determination, and the impact of the correction on the calibrated radiances for a range of scene temperatures and types.
A model of the potential polarization induced calibration bias is presented for the CrIS instrument, along with details of the model parameter determination, and the predicted impact of the correction on the calibrated radiances.
This paper provides a procedure for the simulation of radiances from the U. S. National Oceanic and Atmospheric Administration (NOAA) Cross-track Infrared Sounder (CrIS) Fourier Transform Spectrometer to include spectral ringing effects caused by the finite-band, non-flat instrument spectral response to incident radiation. A simulation using a line-by-line radiative transfer model is performed to illustrate the magnitude of the effect and to indicate which spectral channels are likely to be impacted. Comparisons with CrIS observations are made to show that for most channels this effect is negligibly small compared to errors in the radiative transfer calculations but for the longwave edge of the CrIS longwave band and a few other regions, the brightness temperature ringing is significant. While the ringing artifact described in this paper may appear to be removed when Hamming apodization is applied, as is done for the assimilation of CrIS data into Numerical Weather Prediction (NWP) models, it is still present, and its influence reappears if the spectral correlation induced by apodization is properly handled to preserve the information content that derives from high spectral resolution. Inclusion of the instrument responsivity in calculated spectra to properly mimic the observed spectra as defined here eliminates artifacts from this type of ringing. Users of CrIS radiances should consider whether this effect is important for their application.